Polowo-obwodowy model osiowosymetrycznego aktuatora liniowego
The field-circuit model of axis-symmetrical linear actuator
Autorzy:
Mikołajewicz, J.
Wojciechowski, R. M.
Powiązania:
https://bibliotekanauki.pl/articles/1367685.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
Model polowo-obwodowy
aktuator liniowy
analiza numeryczna
Field-circuit model
linear actuator
numerical analysis
Opis:
In the paper a field-circuit model of axis-symmetrical linear actuator has been presented. An actuator with conical armature has been considered and investigated. The integral parameters of the model, such as the inductance and the force have been determined on the basis of 2D electromagnetic field distributions, which have been obtained for the field model. Then, the calculated parameters have been implemented to the circuit model, ie. the model of the system comprising the coupled equations of the electrical circuit and the mechanical equilibrium equation of the considered actuator. In the considerations, the eddy current effect has not been taken account. The selected results of simulations have been presented.
W artykule przedstawiono polowy-obwodowy model osiowosymetrycznego aktuatora liniowego. Rozpatrywano aktuator nurnikowy z nurem stożkowym. Parametry całkowe modelu, takie jak indukcyjność oraz siła, zostały wyznaczone na podstawie rozkładu dwuwymiarowego pola magnetycznego. Obliczone parametry skupione następnie zaimplementowano w modelu obwodowym przetwornika, tzn. modelu obejmującym układ sprzężonych równań obwodu elektrycznego oraz równania dynamiki. W rozważaniach pominięto tłumiący charakter prądów wirowych. Przedstawiono wybrane wyniki badań symulacyjnych.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2015, 3, 107; 173-177
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza stanu cieplnego wysokoobrotowych maszyn elektrycznych o wzbudzeniu od magnesów trwałych z chłodzeniem cieczowym
Thermal Analysis of High-Speed Permanent Magnet Electrical Machines With Liquid Cooling
Autorzy:
Makarchuk, O.
Lis, M.
Klatow, K.
Gastołek, A.
Sosnowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/1368100.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
maszyny elektryczne wysokoobrotowe o wzbudzeniu od magnesów trwałych
chłodzenie cieczowe
schemat zastępczy termiczny
FEM-analiza
high-speed permanent magnet electrical machines
liquid cooling
thermal analysis
thermal equivalent circuit
FEM analysis
Opis:
The main goal of the submitted research is the development of an effective technique of the thermal calculation of the closed high-speed electric machine with excitation from the constant magnets and liquid cooling. In the work we can consider constructional features of the systems of liquid cooling of such machines with the zigzag- and helical form channels. The analysis of the last researches in the given area showed, that it is expedient to use the FEM-analysis for check of offered methods of the calculation. The entrance data for the formulation of a boundary problem of the calculation of a 3-dimensional thermal field of the machine by capacity 100 kVA, frequency of rotation 30000 RPM are submitted. Results of the calculation of this problem with using of a method of final elements are graphically shown. On the base of the analysis of a field of temperature and a gradient of temperature the structure of a thermal equivalent circuit was synthesized and proved. This structure represents the machine as set of 7 bodies with an internal thermal emission and allows to appraise its thermal condition at the initial stages of designing. Expressions for the calculation of a parameters of this equivalent circuit and a principle of formation of the system of the equations, for the further finding of unknown temperatures are resulted. The comparative analysis of the considered methods of the calculation of a thermal condition of high-speed machines with liquid cooling is carried out. The certain advantages of systems with helical channels are also revealed.
Celem artykułu jest opracowanie metody obliczania stanów termicznych wysokoobrotowych maszyn wzbudzanych magnesami trwałymi chłodzonymi cieczą. W artykule przedstawiono rozwiązania konstrukcyjne systemów chłodzenia cieczą dla różnych kształtów kanałów chłodzących. Analizę obliczeniową przeprowadzono przy zastosowaniu metody FEM. Podano sposób sformułowania warunków brzegowych do wyznaczania trójwymiarowego pola temperaturowego na przykładzie maszyny elektrycznej o mocy 100 kVA i prędkości obrotowej 30000 obr/min. Stosując metodę elementów skończonych przedstawiono symulacyjne wyniki obliczeniowe w formie graficznej. Wykorzystując analizę pola temperaturowego i zmianę temperatury sformułowano strukturę termicznego obwodu zastępczego przedstawiającego analizowaną maszynę w układzie z 7 jednostek wewnętrznych źródeł wytwarzania ciepła. Opracowana struktura w formie obwodu zastępczego daje możliwość wstępnego określania stanu termicznego maszyny elektrycznej w zakresie opracowywania założeń projektowych. Ponadto zaprezentowano analizę porównawczą metod obliczania stanów termicznych wysokoobrotowych maszyn elektrycznych chłodzonych cieczą z uwzględnieniem kształtów kanałów chłodzących.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2015, 1, 105; 7-13
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies