Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "sitarek, A." wg kryterium: Wszystkie pola


Wyświetlanie 1-2 z 2
Tytuł:
Multichannel Optical System for the Quality Control of Digital Printing
Wielokanałowy optyczny system do kontroli jakości druku cyfrowego
Autorzy:
Galas, J.
Litwin, D.
Czyżewski, A.
Sitarek, S.
Kołacz, K.
Powiązania:
https://bibliotekanauki.pl/articles/232507.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
digital printing
material deformation control
optical measurement system
fibre optics
tekstylia
druk cyfrowy
barwienie
system pomiarowy optyczny
światłowody
Opis:
Economical efficiency and environmental protection are key elements of modern textile treatment, where chemical fluids are digitally assigned to designated places in a printinglike process. Except arbitrarily designed colour patterns, technology provides the ability to add individual functionalities not achievable in the classical approach i.e. dip dyeing based processes. The precise deposition of chemicals or bonding components like microelectronic chips on a material substrate is crucial in producing multilayered fabrics. This paper demonstrates an optical monitoring system which enables the precise control of the deposition of functional materials or components on fabric. The optical system consists of a set of Fibre Optic Image Bundles (FOIB) connected to a single CCD line camera which enables the correlation in space and time of images acquired from different parts of the area monitored. During the deposition process the system measures fabric surface deformation and detects motion instability, and then adjusts the printing parameters accordingly.
Czynniki ekonomiczne oraz ochrona środowiska odgrywają kluczową rolę w nowoczesnej technice barwienia materiałów tekstylnych, w której barwniki są nakładane w procesie przypominającym drukowanie. Poza dowolnie zaprojektowanym barwnym wzorem technologia ta pozwala na dodanie indywidualnych cech produktu, co nie jest możliwe do osiągnięcia klasycznymi metodami barwienia zanurzeniowego. Precyzyjne nakładanie na materiał barwników oraz specjalizowanych komponentów, jak na przykład, struktur elektronicznych decyduje o jakości produkcji. Artykuł przedstawia optyczny system monitorujący, który ułatwia dokładne, wielowarstwowe nakładanie na tekstylia barwników i funkcjonalnych materiałów. System optyczny jest złożony z wiązki obrazowodów dołączonych do pojedynczej liniowej kamery CCD, co pozwala na korelację w czasie i przestrzeni obrazów zbieranych z różnych obszarów kontrolnych. W trakcie nakładania warstw system mierzy deformacje powierzchni płótna oraz wykrywa zakłócenia w jego przesuwie, a następnie odpowiednio modyfikuje parametry druku.
Źródło:
Fibres & Textiles in Eastern Europe; 2016, 3 (117); 95-102
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative Safety Testing (Acute Systemic Toxicity in Mice) of Two Materials Prepared from Polypropylene-Polyester (Codubix S) or Acrylate Resin (Mendec Cranio) Used for the Manufacturing of a Calvaria Prosthesis
Porównawcze badanie bezpieczeństwa (ostra toksyczność ogólnoustrojowa u myszy) dwóch materiałów przygotowanych z dzianiny/plecionki polipropylenowo-poliestrowej (Codubix S) oraz żywicy akrylowej (Mendec Cranio) wykorzystywanych do produkcji protez
Autorzy:
Sujka, Witold
Latańska, Ilona
Stępnik, Maciej
Sitarek, Krystyna
Kasprzak, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/234064.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
cranial implant
cranioplasty
acute toxicity
chemical analysis
polypropylene-polyester
acrylate resin
implant czaszki
plastyka czaszki
ostra toksyczność
analiza chemiczna
polipropylen-poliester
żywica akrylowa
Opis:
The aim of the study was a comparison of the acute toxicity of two popular prostheses used in the reconstruction of the bones of the skull. For the tests, the following materials were used: a polypropylene-polyester knitted Codubix S cranial bone prosthesis, made by TRICOMED SA, and polymethyl methacrylate Mednec Cranio resin. The tests were carried out in accordance with the following standards – PN-EN ISO 10993-11:2009 Biological evaluation of medical devices - Part 11: Tests for systemic toxicity, and PN-EN ISO 10993-12:2012 Biological evaluation of medical devices – Part 12: Sample preparation and reference materials. During the evaluation, adult male and female Balb/c mice were used. The animals were injected intravenously using extracts of both materials in 0.9% NaCl and intraperitoneally with the same extracts in sesame oil. The tests lasted 7 days, during which the health of the animals and their behavior were assessed. Both in the control and test groups, there was no mortality of the animals, and the health and behaviour of mice were unchanged when compared with the normal. After 7 days the internal organs of the chest and abdominal cavity of the animals were subjected to macroscopic pathomorphological examination, during which no changes indicating the toxic action of Codubix S and Mednec Cranio resin were found. Before the acute systemic toxicity tests, the chemical purity of both implants was assessed. The chemical purity of a product is one of the factors determining its biological properties. A product which is characterised by a higher degree of chemical purity contains fewer substances which may have a negative impact on biological reactions. Both prostheses meet the requirements of purity for medical devices.
Celem badania było porównanie toksyczności ostrej dwóch popularnych protez stosowanych w konstrukcji kości czaszki. Do badań użyto następujących materiałów: dzianiny polipropylenowo-poliestrowej Codubix S firmy TRICOMEX SA. I polimetakrylanu metylu Mednec Cranio. Badania przeprowadzono zgodnie z następującymi normami PN-EN ISO 10993-11: 2009 Biologiczna ocena wyrobów medycznych. Część 11: Badania toksyczności systemowej i PN-EN ISO 10993-12: 2012 Biologiczna ocena wyrobów medycznych Część 12: Przygotowanie próbek i materiały referencyjne. Podczas oceny wykorzystano dorosłe samce i samice myszy Balb /c. Zwierzętom wstrzyknięto: dożylnie stosując ekstrakty obu materiałów w 0,9% NaCl i dootrzewnowo z tymi samymi ekstraktami w oleju sezamowym. Testy trwały 7 dni, podczas których oceniano zdrowie zwierząt i ich zachowanie. Zarówno w grupach kontrolnych, jak i testowych nie stwierdzono śmiertelności zwierząt, zdrowie i zachowanie myszy pozostały nie zmienione w porównaniu ze zwykłymi. Po 7 dniach narządy wewnętrzne klatki piersiowej i jamy brzuszne j zwierząt poddano makroskopowemu badaniu patomorfologicznemu, podczas którego nie stwierdzono zmian wskazujących na toksyczne działanie żywicy Codubix S i Mednec Cranio. Przed badaniami ostrej toksyczności ogólnoustrojowej oceniano czystość chemiczną obu implantów. Chemiczna czystość produktu jest jednym z czynników określających jego właściwości biologiczne. Produkt, który charakteryzuje się wyższym stopniem czystości chemicznej, zawiera mniej substancji, które mogą mieć negatywny wpływ na reakcje biologiczne. Obie protezy spełniają wymagania czystości dla wyrobów medycznych.
Źródło:
Fibres & Textiles in Eastern Europe; 2019, 5 (137); 82-88
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies