Influence of Bioaugmentation Strategy of Activated Sludge on the Co-Treatment of Reject Water and Municipal Wastewater at a Decreasing Temperature
Autorzy:
Szaja, Aleksandra
Szulżyk-Cieplak, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/125053.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
bioaugmentation
reject water
SBR
decreasing temperature
Archaea
Opis:
In the present study, the influence of bioaugmentation strategy on the co-treatment of 13% v/v reject water and municipal wastewater at a decreasing temperature was evaluated. The experiment was performed in two identical laboratory sequencing batch reactors with the active volume of 8 L. Each one was operated using a 12-hour cycle at sludge retention time of 3 d. The SBR A was bioaugmented with a mixture of wild-living bacteria and Archaea in a dose 0.25 ml. In turn, the comparative reactor (SBR B) was non-bioaugmented, the Archaea product was replaced with an equal volume of dechlorinated tap water. The experiment was divided into 3 phases, each with a different temperature range (20, 15 and 10°C). The temperature reduction did not adversely affect the process performance in the bioaugmented and non-bioaugmented system. Significant removal efficiencies were achieved in both SBRs. The major differences were observed for the COD content in the bioaugmented SBR at a temperature of 10°C. In this case, statistically lower concentrations in the effluent were observed in the bioaugmented system than in the non-bioaugmented one. Additionally, at a temperature of 10°C, an improved process performance was observed in the Archaea presence, but the differences were of no statistical significance.
Źródło:
Journal of Ecological Engineering; 2020, 21, 5; 97-106
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Effect of Bioaugmentation Strategy on the SBR Performance Treating Reject Water and Municipal Wastewater Under Various Temperature Conditions
Autorzy:
Szaja, Aleksandra
Szulżyk-Cieplak, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/1955439.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
activated sludge
Archaea
bioaugmentation
reject water
temperature fluctuation
Opis:
In this study, the effect of bioaugmentation on the sequencing batch reactor (SBR) performance while treating municipal wastewater and reject water under various temperature conditions was examined. Two lab-scale SBRs, each with the active volume of 8 L were used to perform this research. For bioaugmentation, a mixture of wildliving Bacteria and Archaea in a dose 0.25 mL was added to SBR A, while SBR B was a control one. Both reactors were fed with a mixture of wastewater and 13% v/v reject water. During the experiment, 5 phases with different temperature range were distinguished, each one lasted 14 d. The temperatures were investigated in 5°C increments, i.e. 20, 25, 30, 25 and 20°C. The obtained results indicated that in the bioaugmented reactor (SBR A), lower concentrations of NH4+–N, TSS, NO2-–N in effluent were observed as compared to control (SBR B). While for NH4+–N, regardless the temperature, the observed differences were statistically significant. Importantly, in both SBRs, the process was carried out in a stable way.
Źródło:
Journal of Ecological Engineering; 2021, 22, 7; 46-56
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of Aerobic Stabilization of Sewage Sludge on PAHs Concentration in Reject Waters
Autorzy:
Kozak, Jolanta
Włodarczyk-Makuła, Maria
Popenda, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/1839628.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
PAHs
municipal sewage sludge
coking sewage sludge
reject water
aerobic stabilization
Opis:
In the paper, the results of studies on changes in the concentration of selected polycyclic aromatic hydrocarbons (PAHs) in the reject water coming from aerobic stabilization of sewage sludge process were given. The sewage sludge samples originating from a treatment of municipal wastewater treatment plant and an industrial coking wastewater treatment plant were investigated. A technological study was conducted using a municipal sewage sludge (control sample) and a mixture of municipal and industrial sewage sludge simultaneously. Aerobic stabilization of sewage sludge process was carried out for 21 days. The concentration of PAHs was determined at the beginning of the experiment (day 0) and in seven-day intervals: after 7, 14 and 21 days. The initial concentration of PAHs in the reject water coming from the municipal sewage sludge was over 44 g/dm3. Industrial sewage sludge was heavily loaded with polycyclic aromatic hydrocarbons. In a reject water of the mixture of municipal and industrial sludge, the initial content of PAHs reached over 5200 g/dm3. During aerobic stabilization of sewage sludge, a decrease in PAHs concentration in reject water was observed. After 21 days of the experiment, the decrease of the sum of analyzed PAHs was in the range of 62–98%.
Źródło:
Journal of Ecological Engineering; 2021, 22, 4; 27-35
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of Organic Substances and Ammonia Nitrogen Removal in Vertical Flow Constructed Wetlands
Autorzy:
Malinowski, Paweł
Dąbrowski, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/124762.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
treatment modeling
vertical flow constructed wetlands
reject water
organic substances
ammonia nitrogen
Opis:
The aim of the research was to determine the possibility of using and adapting regression models for a description of constructed wetland systems treating reject water from aerobic sewage sludge stabilization. The P-k-C* model was investigated along with related models. The research was carried out using reject water from aerobic sewage sludge stabilization in dairy wastewater treatment plant (WWTP) belonging to Mlekovita in Wysokie Mazowieckie. The main components of the research installation were two vertical flow constructed wetland beds with passive aeration operating at 0.1 m/d hydraulic load. The following parameters were used for modeling: BOD5, COD, N-NH4+ and temperature. Air temperature was also monitored.
Źródło:
Journal of Ecological Engineering; 2020, 21, 1; 231-237
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of SS-VF Bed for the Treatment of High Concentrated Reject Water from Autothermal Termophilic Aerobic Sewage Sludge Digestion
Autorzy:
Dąbrowski, W.
Malinowski, P.
Karolinczak, B.
Powiązania:
https://bibliotekanauki.pl/articles/123643.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
autothermal thermophilic aerobic digestion
ATAD
reject water
vertical flow constructed wetland
SS VF
Opis:
The autothermal termophilic aerobic digestion (ATAD) technology is used in the municipal and industrial wastewater treatment plants (WWTPs) with personal equivalent up to 30.000. The process provides a high level of sewage sludge stabilization and its hygienization. The main operation problems are caused by the high concentration of nitrogen and phosphorus in the reject water from sewage sludge treatment and air purification (odor removal). Reject water usually is returned to the main sewage treatment, which has a negative impact, especially on the sewage treatment systems based on the sequence batch reactors (SBR). Applying high-performance and expensive separate reject water treatment methods such as SHARON, Anammox or CANON in small facilities is not justified economically. The article presents the research results concerning the effectiveness of applying subsurface vertical flow constructed wetlands (SS VF) for reject water treatment from the ATAD process. An innovative type of bed filling was used, which was produced from waste (ash from a heat and power plant). The efficiency of reject water treatment during the research period was on average at 45.6% for ammonia nitrogen, 32.3% for total phosphorus and 85.1% for BOD5. Applying SS VF beds for separate reject water treatment might ensure a stable and effective functioning of municipal WWTPs by decreasing the load of biological part of a WWTP.
Źródło:
Journal of Ecological Engineering; 2018, 19, 4; 103-110
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie fosforanów z pofermentacyjnych cieczy osadowych
Phosphates removal from reject water from digestion of sludge
Autorzy:
Sperczyńska, E.
Powiązania:
https://bibliotekanauki.pl/articles/400054.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
usuwanie fosforanów
ciecze osadowe
wstępnie zhydrolizowane koagulanty
phosphates removal
reject water
prehydrolysed coagulants
Opis:
Badania prowadzono w kierunku oceny przydatności koagulantów stosowanych w skali technicznej w procesach oczyszczania wody do zmniejszenia zawartości fosforanów w cieczach osadowych. Celem badań była ocena efektywności usuwania związków fosforu z cieczy osadowych pofermentacyjnych przy zastosowaniu wstępnie zhydrolizowanych chlorków poliglinu (nisko, średnio i wysoko zasadowych) oraz siarczanu glinu jako koagulanta odniesienia. Do badań wykorzystano ciecze osadowe pochodzące z odwadniania przefermentowanych komunalnych osadów ściekowych z oczyszczalni ścieków o RLM powyżej 100 000. Jako środków strącających użyto produkty handlowe wstępnie zhydrolizowanych chlorków poliglinu PAX 18, PAX XL10, PAX-XL1905 oraz siarczan glinu. Badania wykonano dla trzech różnych dawek dla każdego z koagulantów: 0,7; 1,0; 1,5 krotności dawki stechiometrycznej wynikającej z reakcji chemicznej tworzenia nierozpuszczanego fosforanu glinu. Surowe ciecze osadowe charakteryzowały się bardzo wysokimi stężeniami związków azotu (891 mgNKj/dm3), fosforanów (125 mgPO43-/dm3) oraz związków organicznych oznaczonych jako ChZT (592 mgO<2/dm3). W procesie chemicznego strącania najwyższą efektywność usuwania fosforanów uzyskano dla najwyższych stosowanych dawek dla wszystkich koagulantów. Najwięcej fosforanów usunięto przy użyciu PAX 18 (96%). Równocześnie ze zmniejszeniem ilości związków fosforu zanotowano niewielkie zmniejszenie ilości związków organicznych oznaczanych jako ChZTCr, maksymalnie 47% przy zastosowaniu wysokozasadowego PAX XL 1905. Zastosowani najmniejszej dawki pozwoliło osiągnąć efektywność usuwania fosforanów na poziomie 50% dla Al2(SO4)3 oraz 83% dla PAX 18.
The aim of the research work was to evaluate if coagulants used on technical scale are useful in phosphates removal from reject water. Effectiveness of phosphorus compounds removal from reject water from digestion of sewage sludge was examined. Selected prehydrolysed alkaline aluminium polychlorides were used. The results were compared to the ones obtained with aluminium sulphate. Reject water from digestion of sewage sludge form WWTP of 100 000 PE were examined. Commercial agents – prehydrolysed PAX 18, PAX XL10, PAX-XL1905 as well as aluminium sulphate were used. Various doses of coagulants: 0.7; 1.0; 1.5 – time higher than stoichiometric dose were applied. Stoichiometric dose was calculated based on chemical reaction of insoluble aluminium phosphate formation. Concentrations of Kiejdahl nitrogen (891 mgNKj/dm3), phosphates (125 mgPO43-/dm3) and organic compounds – COD (592 mgO2/dm3) in reject water were very high. The effectiveness of coagulation process increased as the doses of chemical agents increased. The most effective doses were the highest ones used during the experiment. The most effective agent was PAX 18 (96% removal efficiency). As the phosphates concentration decreased COD content declined simultaneously. Maximum COD removal (47%) was obtained when highly alkaline PAX XL 1905 was used. Use of the lowest dose of Al2(SO4)3 allowed for 50% phosphates removal, whereas the lowest dose of PAX 18 decreased phosphates concentration by 83%.
Źródło:
Inżynieria Ekologiczna; 2016, 48; 196-201
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność oczyszczania odcieków z beztlenowej stabilizacji osadów z oczyszczalni ścieków mleczarskich na złożu biologicznym
Application of trickling filter for sewage treatment with high ammonia nitro gen concentration
Autorzy:
Dąbrowski, W.
Horysz, M.
Powiązania:
https://bibliotekanauki.pl/articles/401081.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
złoże biologiczne
odcieki z przeróbki osadów
efektywność
trickling filter
reject water from sewage treatment
efficiency
Opis:
W artykule przedstawiono wyniki badań dotyczących możliwości zastosowania złoża biologicznego z wypełnieniem z tworzywa do oczyszczania ścieków charakteryzujących się wysokim stężeniem azotu amonowego. Badania prowadzono z zastosowaniem odcieków, powstających w trakcie beztlenowej stabilizacji osadów w oczyszczalni ścieków mleczarskich. Są one z reguły zawracane do głównego ciągu oczyszczania. Ich duża ilość powoduje zakłócenia w pracy oczyszczalni ścieków mleczarskich. BZT5 odcieków było porównywalne z wartościami charakterystycznymi dla ścieków bytowych, natomiast stężenie azotu amonowego zmieniało się od 145,0 do 390,0 mg N-NH4+/l, a fosforu ogólnego od 16,0 do 38,0 mg P/l. W badaniach wykorzystano układ badawczy CE701e firmy Gunt umożliwiający kontrolę podstawowych parametrów procesu. Złoże biologiczne w układzie niskoobciążonym umożliwiło znaczne obniżenie zawartości substancji organicznej oraz azotu ogólnego i amonowego. Średnia efektywność usuwania azotu amonowego wynosiła od 73,6 do 80,3%. W przypadku azotu Kjeldahla średnia efektywność usuwania wynosiła od 74,4 do 79,8%. Ze względu na warunki tlenowe panujące w trakcie oczyszczania efektywność usuwania fosforu była niska i zmieniała się od 32,0 do 33,7%. Wykonane badania potwierdziły skuteczność złóż biologicznych w oczyszczaniu ścieków charakteryzujących się dużym stężeniem azotu amonowego.
The article presents the results of research about the possibility of using trickling filter for high ammonia concentration sewage treatment. The study was conducted with the use of reject water generated during anaerobic sewage sludge stabilization in dairy wastewater treatment plant (WWTP. They are usually returned to the beginning of WWTP. The value of BOD in reject water was approximately the same as in domestic and municipal sewage. Ammonia nitrogen concentration was varied from 145,0 to 390,0 mg N-NH4+/l and phosphorus from 16.0 to 38.0 mgP/l. The study used the Gunt test system CE701e, which allows controlling basic parameters of the treatment with trickling filter. Significant reduction of organic matter, total nitrogen and ammonium was observed during treatment. Average removal efficiency of ammonia nitrogen ranged from 73.6 to 80.3%. In the case of the Kjeldahl nitrogen removal efficiencies ranged from 74.4 to 79.8%. Because of the aerobic conditions during the treatment of phosphorus removal efficiency was low and varied from 32.0 to 33.7%. The research confirmed the efficiency of trickling filter for treatment sewage with high concentration of ammonia nitrogen.
Źródło:
Inżynieria Ekologiczna; 2016, 47; 89-94
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka ścieków i osadów z oczyszczalni komunalnej stosującej technologię firmy „Biopax”
The quality of sewage and sewage sludge from the municipal wastewater treatment plant using „Biopax” technology
Autorzy:
Królak, E.
Biardzka, E.
Bramowicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/401786.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ścieki
osady
odcieki
efektywność oczyszczania
technologia firmy „BIOPAX”
sewage
sewage sludge
reject water
efficiency
BIOPAX technology
Opis:
Celem badań była ocena redukcji zanieczyszczeń w ściekach komunalnych oraz analiza składu chemicznego osadów ściekowych i odcieków w komunalnej oczyszczalni w Komorach Dąbrownych. Oczyszczanie ścieków oparte jest na technologii firmy BIOPAX. Ocenie poddano odczyn oraz stężenie biogenów w ściekach surowych i oczyszczonych, zawartość materii organicznej oraz azotu i fosforu całkowitego w osadach uwodnionych i ustabilizowanych. Określono także skład odcieków. Stwierdzono, że zastosowana technologia zapewnia skuteczną (na poziomie powyżej 96%) redukcję biogenów w ściekach. Skład chemiczny osadów ściekowych po ich stabilizacji jest typowy dla osadów wytwarzanych w komunalnych oczyszczalniach ścieków, a odcieki włączane do procesu technologicznego nie wpływają negatywnie na proces technologiczny. Ze względu na wysoką redukcję biogenów oczyszczalnie oparte na opisanej technologii wydają się być dobrym rozwiązaniem dla oczyszczania ścieków w małych miejscowościach.
The aim of the study was the assessment of contaminants reduction from communal sewage and the analysis of the chemical composition of sewage sludge and reject waters from Komory Dąbrowne sewage treatment plant using devices designed and built by BIOPAX Ltd. The scope of the research included assessing the following aspects: reaction (pH), the concentration of nutrients in raw and treated sewage, the concentration of organic matter and the content of total nitrogen and phosphorus in sludge before and after stabilization. The characteristic of reject water was also presented. It was found that technology provides more than 96% reduction of nutrients from the sewage. Chemical composition of stabilized sewage sludge is similar to the communal waste produced in other sewage treatment plants, while the reject waters used in the treatment process do not influence the technological process in an adverse way. Due to its high capacity of nutrient reduction, technology seems to be a useful tool to be applied in small municipal wastewater treatment plants (WWTPs).
Źródło:
Inżynieria Ekologiczna; 2016, 48; 119-124
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oczyszczanie odcieków z mechanicznego odwadniania przefermentowanych osadów ściekowych w wielostopniowych złożach hydrofitowych
Treatment of reject water from digested sludge dewatering in multistage constructed wetland
Autorzy:
Gajewska, M.
Powiązania:
https://bibliotekanauki.pl/articles/401181.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
odcieki z odwadniania przefermentowanych osadów
oczyszczalnia hydrofitowa
złoża z pionowym i poziomym przepływem ścieków
reject water from sewage sludge dewatering
treatment wetlands
role of SS VF and SS HF beds
Opis:
Zawracanie odcieków z odwadniania przefermentowanych osadów ściekowych ma niekorzystny wpływ na pracę oczyszczalni i w konsekwencji powoduje wzrost stężenia azotu ogólnego w oczyszczonych ściekach. W roku 2008 zaprojektowano i wybudowano pilotowy obiekt hydrofitowy, w skali technicznej, do podczyszczania odcieków powstających podczas mechanicznego odwadniania przefermentowanych osadów ściekowych w oczyszczalni w Gdańsku. Celem prowa-dzanych badań była ocena efektywności usuwania zanieczyszczeń oraz znaczenie zastosowanych stopni technologicznych w oczyszczaniu odcieków. W pracy przedstawiono wyniki badań z lat 2009 i 2010. Analizowany obiekt zapewniał bardzo skuteczne usuwanie podstawowych zanieczyszczeń: ChZT - 76% i N-NH4+ - 93%. Przeprowadzone badania potwierdzają możliwość zastosowania metody hydrofitowej do oczyszczania ścieków o wysokich ładunkach zanieczyszczeń, w tym odcieków z mechanicznego odwadniania przefermentowanych osadów ściekowych.
The return flows of reject water from sewage sludge dewatering alter the activated sludge process in a conventional WWTP and increase TN concentration in the final effluent from WWTP. The full scale pilot plant for reject water from digested sludge dewatering, consisting of two SS VF beds working in series, followed by an SS HF, was build in 2008 (TW - treatment wetland). This paper aims to present the design and performance of each stage of the treatment as well as the efficiency of entire system. The applied configuration ensured a very high removal efficiency of principal pollutant (COD - 76% and NH4+-N - 93.6%). In the investigated facilities, the SS VF beds ensured an effective removal of nitrogen compounds, especially NH4+-N, whereas the decomposition of hardly degradable Org-N and COD took place in SS HF. This research illustrates that the treatment wetlands technology could be successfully applied for the treatment of reject water from centrifuge (RWC).
Źródło:
Inżynieria Ekologiczna; 2011, 25; 86-98
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies