Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "sewage plant" wg kryterium: Temat


Wyświetlanie 1-8 z 8
Tytuł:
The efficiency of pollutant elimination in the Dobra treatment plant
Autorzy:
Nowak, J.
Chmielowski, K.
Chmielowska, B.
Bedla, D.
Powiązania:
https://bibliotekanauki.pl/articles/101622.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
sewage treatment plant
domestic sewage
SBR
Opis:
This study was aimed to conduct an analysis of the efficiency of pollutant elimination in the Dobra treatment plant, which operates based on the SBR reactor. The object purifies domestic sewage and pre-treated industrial sewage from a slaughterhouse within the Dobra municipality. The source material for the analysis comprised the values of pollution indicators: BOD5 , CODCr, total suspended solids (TTS) in raw sewage (19 samples) and treated sewage (34 samples). The results of chemical analyses were obtained in the period 2007-2014. The results were compared with the limit values imposed by the Regulation (2014). The coefficient of reliability of the treatment plant was also calculated in this study. The average efficiency of pollutant elimination in the treatment plant was: BOD5 - 98.6%, CODCr - 94.9%, total suspended solids - 97.6%. These results demonstrate that the studied facility operates flawlessly and the treatment efficiency is high. On the other hand, the reliability coefficient values indicate that the operation of this object is unstable.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, III/1; 737-747
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of sewage susceptibility to biodegradation on an example of sewage treatment plant in Wodzisław Śląski
Autorzy:
Chmielowski, K.
Wąsik, E.
Operacz, A.
Bugajski, P.
Kaczor, G.
Jurik, L.
Powiązania:
https://bibliotekanauki.pl/articles/101267.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
sewage biodegradation
sewage composition
sewage treatment plant
Opis:
The paper presents an analysis of sewage susceptibility to biodegradation on an example of sewage treatment plant in Wodzisław Śląski in the Śląskie province. For this purpose, dependencies between selected indices of domestic sewage pollution were applied. Descriptive statistics of the respective indices rations COD/BOD5 , BOD5 /TN, BOD5 /TPwere presented. Moreover, an analysis was conducted on the composition of raw sewage flowing into the treatment plant, pre-treated sewage and sewage leaving the studied treatment plant. The analysis was carried out on the basis of three basic indices of sewage pollution (BOD5 , COD and total suspended solids) and two biogenic indices (total nitrogen and total phosphorus). Tests on the sewage composition were conducted in the years 2010-2015. Basic descriptive statistics were compiled for the values of the studied indices of sewage pollution and the obtained results were interpreted. On the basis of collected material it may be said that sewage reaching the treatment plant in Wodzisław Śląski revealed a good susceptibility to biodegradation, whereas the BOD5 /TN and BOD5 /TP ratios were below the optimum value.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2017, IV/1; 1427-1443
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of heavy precipitation on the infiltration and inflow into small sewage treatment plants in 2010
Autorzy:
Kaczor, G.
Powiązania:
https://bibliotekanauki.pl/articles/60233.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
heavy rainfall
infiltration
inflow
small sewage treatment plant
sewage treatment plant
sewer system
weather
treatment plant
Malopolska voivodship
Krakow city
mechanical treatment plant
biological treatment plant
modernization
Opis:
The aim of the study was to determine the extent to which heavy rainfall, that occurred in 2010, affected the infiltration into the selected sewage treatment plants in the Małopolskie voivodeship. The research was conducted in four separate sewer systems, located in poviats adjacent to the city of Kraków, discharging sewage to mechanical-biological treatment plants with a capacity below 1000 m3•d-1. The amount of sewage and extraneous water in the average wet year (2008) were used as control. As a result of heavy precipitation in 2010 the sewer system A received 18 539 m3 more extraneous water than in 2008 (increase by 343%), the sewer sys-tem B - 22 822 m3 (increase by 163%), the sewer system C - 109 715 m3 (increase by 248%) and the sewer system D - 30 796 m3 (increase by 303%). Heavy precipitation in 2010 caused the increase of infiltration and inflow by 264% on average in all studied sewer systems compared to the average wet year. As the result of precipitation, whose annual total in 2010 was higher by 65% than the normal value in 2008, there was an increase in the annual share of extraneous water from 5.3 to 19.7% depending on the facility. The volume of extraneous water, which was discharged into the studied treatment plants in 2010 (the period of heavy rainfall), constituted the following share of the annual value: in the sewer system A - 41.3%, in the sewer system B - 21.2%, in the sewer system C - 14.4%, in the sewer system D - 22.9%. Assuming the average gross amount of 3 PLN paid for treatment of 1 m3 of sewage, cost of extraneous water disposal in 2010 amounted from 78 533 PLN to 552 165 PLN, depending on the facility. The results obtained in the present study suggest that eliminating or reducing infiltration and inflow into the analyzed sewer systems would allow for large financial savings associated with reducing costs both for their transport and treatment as well as for modernization of facilities to enhance their hydraulic eapacity.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2011, 12
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ ścieków oczyszczonych na oczyszczalni w Myślenicach na jakość wód ich odbiornika
Impact of treated sewage on sewagetreatment plant in Myślenice on the quailty of their receiver
Autorzy:
Miernik, W.
Młyński, D.
Wałęga, A.
Chmielowski, K.
Karwacki, A.
Powiązania:
https://bibliotekanauki.pl/articles/101265.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
ścieki
oczyszczalnia
odbiornik
rzeka Raba
sewage
sewage treatment plant
receiver
Raba river
Opis:
Artykuł zawiera analizę i ocenę wpływu ścieków oczyszczonych w oczyszczalni w Myślenicach w latach 2008 - 2011, na skład fizyczno-chemiczny oraz jakość wód ich odbiornika - rzeki Raby. Pracę wykonano na podstawie zebranych oraz statystycznie opracowanych wyników badań, obejmujących ilość i skład ścieków oczyszczonych, odprowadzanych do Raby, a także skład wód odbiornika w przekrojach Stróże i Osieczany, znajdujących się odpowiednio powyżej i poniżej punktu zrzutu ścieków oczyszczonych. Zakres wskaźników zanieczyszczeń oznaczanych w ściekach i wodzie obejmował: zawiesinę ogólną, BZT5 , ChZTCr, fosfor ogólny oraz azot ogólny. Na podstawie wykonanych badań stwierdzono, że oczyszczalnia ścieków w Myślenicach, w latach 2008 - 2011, funkcjonowała prawidłowo, ponieważ oczyszczone na niej ścieki, spełniały wymogi pozwolenia wodno-prawnego, co przekładało się bezpośrednio na skuteczną ochronę przed zanieczyszczeniem wód ich odbiornika. Ponadto stwierdzono, że w obu badanych przekrojach skład fizyczno-chemiczny wód Raby był do siebie zbliżony. Potwierdziły to wyniki zastosowanego testu U Mann'a-Whitney'a, które nie wykazały statystycznie istotnych różnic pomiędzy średnimi wartościami stężeń analizowanych wskaźników zanieczyszczeń. Ścieki oczyszczone, odprowadzane z oczyszczalni w Myślenicach do rzeki Raby nie przyczyniają się do pogorszenia jakości jej wód.
The article contains analysis and evaluation of the impact of clean sewage on sewage treatment plant in Myślenice, in the period 2008 - 201,1 on the physico-chemical composition and water quality of the receiver - river Raba. The analysis conducted based on collected and statistical research: amount and composition of clean sewage and composition of the water receiver in cross-section: Stróże (above of inflow clean sewage) and Osieczany (below of inflow clean sewage). The following pollution index were tested: total suspended solids, BOD5, CODCr, total nitrogen and total phosphorus. Based on obtained results its concluded that in period 2008 - 2011 sewage treatment plant was working properly, what explain quality of clean sewage. What reflected in directly protection of receiver water against pollution. Moreover, based on the results of U Mann Whitney test, concluded that in the both cross-section, composition of the water of Raba river was similar, what explain the results of this test, which didn't show statistically significant differences between average values of concentrations analyzed indicators of pollutions. Based on obtained results its concluded that sewage treatment plant in Myślenice doesn't negatively impact on quality of the water receiver -Raba river.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, I/1; 191-207
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena skuteczności pracy oczyszczalni ścieków w Jaśle
Evaulation of efficency of sewage treatment plant in Jasło
Autorzy:
Młyński, D.
Chmielowski, K.
Młyńska, A.
Miernik, W.
Powiązania:
https://bibliotekanauki.pl/articles/101438.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
ścieki
oczyszczalnia ścieków
niezawodność pracy
sewage
sewage treatment plant
reliability of work
Opis:
Artykuł zawiera ocenę funkcjonowania oczyszczalni ścieków w Jaśle, w wieloleciu 2010 - 2014. Na podstawie wyników badań fizyko-chemicznych ścieków surowych i oczyszczonych wyznaczono wskaźniki niezawodności pracy oczyszczalni takie jak: sprawność oczyszczania, współczynnik niezawodności technologicznej, technologiczną sprawność oczyszczania oraz ryzyko negatywnej oceny działania oczyszczalni, w odniesieniu do następujących wskaźników zanieczyszczeń: zawiesina ogólna, BZT5 , ChZTCr, azot ogólny oraz fosfor ogólny. Na podstawie przeprowadzonych, badań stwierdzono, że średnia redukcja ładunku zanieczyszczeń kształtowała się na poziomie powyżej 90%. Tylko w przypadku azotu ogólnego średnia redukcja była niższa i wynosiła 77%. Bazując na wynikach obliczeń pozostałych wskaźników niezawodności stwierdzono, że badana oczyszczalnia ścieków działała poprawnie i oczyszczała ścieki, których skład spełniał wymogi pozwolenia wodno-prawnego.
The article contains evaluation of functionality of sewage treatment plant in Jasło for multiplicity 2010 - 2014. On the basis of the results raw and cleaned sewage physico-chemical analysis, the efficiency of sewage treatment, coefficient of technological reliability, technological efficiency of sewage treatment and risk of the negative assessment of work of sewage treatment plant, were obtained, for following pollutions indicators: total suspended solids, BOD5 , CODCr, total nitrogen and total phosphorus. Based on obtained results its conclude the average reduction of pollution on level below 90%. Only for total nitrogen the average reduction is lower and is on level 77%. Based on other values of indicators of reliability work of sewage treatment plant its conclude that the tested sewage treatment plant may be certified to operate in high quality and the sewage treated by this plant doesn't threaten the collector of the treated sewage.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, I/1; 147-162
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zmienności dopływu ścieków do oczyszczalni dla aglomeracji Dębica
Analysis of sewage inflow variability to a sewage treatment plant for the agglomeration of Dębica
Autorzy:
Chmielowski, K.
Bugajski, P.
Wąsik, E.
Cupak, A.
Powiązania:
https://bibliotekanauki.pl/articles/101536.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
ścieki bytowe
dopływ ścieków
oczyszczalnia ścieków
domestic sewage
hydraulic load
sewage treatment plant
Opis:
W pracy dokonano analizy zmienności dopływu ścieków do oczyszczalni w Dębicy. W tym celu określono podstawowe statystyki opisowe dotyczące dopływu ścieków do oczyszczalni: wartość średnia (Qdśr), mediana (Mo), wartość minimalna (Qdmin), wartość maksymalna (Qdmax), odchylenie standardowe, współczynnik zmienności (Vzm), rozstęp (Ro). Określono histogram liczby dopływów ścieków do oczyszczalni dla zadanych przedziałów obserwacji. Zestawiono szczegółowe dobowe dopływy ścieków surowych do oczyszczalni w Dębicy w latach 2019-2015 na tle wartości dopuszczalnej z pozwolenia wodno-prawnego oraz wartości średniej. Zestawiono średnie dobowe wartości przepływów ścieków dla poszczególnych miesięcy roku dla okresu 2009-2015. Dokonano zestawienia średnich dobowych przepływów ścieków w poszczególnych latach badanego okresu. Zestawiono średnie dobowe wartości przepływów ścieków w poszczególnych dniach tygodnia dla okresu 2009-2015. Ponadto pozyskano dane opadowe ze stacji w Tarnowie (najbliższa stacja opadowa od badanego obiektu) i na tej podstawie określono średnie wartości dobowego opadu atmosferycznego dla poszczególnych miesięcy w latach 2009-2015. Następnie dokonano podziału dób okresu badawczego ze względu na wielkość opadów atmosferycznych na 7 zasadniczych grup. Określono wpływ opadów atmosferycznych na ilość ścieków dopływających do badanego obiektu. Stwierdzono znaczący wpływ opadów atmosferycznych na dopływ ścieków do oczyszczalni w Dębicy.
The paper analyzes the variability of sewage inflow to a treatment plant in Dębica. For this purpose, the following basic descriptive statistics of the sewage inflow to the treatment plant were determined: mean value (Qdm), median (Mo), minimum value (Qdmin), maximum value (Qdmax), standard deviation, coefficient of variation (Vzm), range (Ro). Histogram of a number of sewage inflows to the treatment plant for the specified observation intervals was determined. Detailed diurnal raw sewage inflows to the treatment plant in Dębica were summarized for the period of 2009-2015 compared to the limit value specified by the water-legal permit and the to the mean value. Mean diurnal sewage flow values for individual months from the period of 2009-2015 were also summarized. Mean diurnal sewage flows in individual years of the studied period, as well as mean diurnal sewage flow values in each day of the week were compared. Moreover, runoff data were obtained from the Tarnów station (the nearest rainfall station to the studied facility) and on this basis mean values of diurnal precipitation for individual months in the period of 2009-2015 were determined. Subsequently, the days of the study period were divided into 7 major groups based on the amount of atmospheric precipitation. The effect of precipitation on the amount of sewage flowing into the studied facility was examined and it was found that the precipitation has a significant effect on the sewage inflow to the treatment plant in Dębica.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, II/2; 589-603
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ lokalizacji oczyszczalni na temperaturę dopływających do niej ścieków
Influence of treatment plant location on temperature of inflowing sewage
Autorzy:
Kaczor, G.
Bugajski, P.
Chmielowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/101199.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
oczyszczalnia ścieków
ścieki
kanalizacja
temperatura ścieków
wastewater treatment plant
wastewater
sewage system
wastewater temperature
Opis:
Celem przeprowadzonych badań było uzyskanie wiedzy, jak umiejscowienie oczyszczalni względem zlewni kanalizacyjnej wpływa na temperaturę dopływających do niej ścieków. Analizą objęto cztery systemy kanalizacyjne, różniące się długością kolektora tranzytowego pomiędzy oczyszczalnią a zabudowaniami mieszkalnymi, w których wytwarzane były ścieki bytowe. W badanych systemach kanalizacyjnych ścieki odprowadzane były do oczyszczalni o przepustowości hydraulicznej od 100 do 300 m3·d-1, charakteryzujących się liczbą RLM nie większą niż 2000. Pomiary temperatury ścieków odpływających z kanalizacji oraz powietrza atmosferycznego, w analizowanym roku 2012, prowadzono w sposób ciągły, z interwałem 1 godzinnym, za pomocą czujników rezystancyjnych połączonych z rejestratorami danych. Przeprowadzone badania wykazały, że odległość oczyszczalni od zlewni kanalizacyjnej wywiera istotny wpływ na temperaturę ścieków odpływających z sieci kanalizacyjnej. W okresie zimowym średnia dobowa temperatura ścieków odpływających z kolektorów tranzytowych o długości od 300 do 600 m była niższa nawet o blisko 3ºC, natomiast w okresie letnim aż o 8ºC, w porównaniu do kolektorów tranzytowych o długości nieprzekraczającej 10 m. Wykazano ponadto, że na temperaturę ścieków dopływających do oczyszczalni, oprócz długości kolektora tranzytowego, istotnie wpływa także natężenie przepływu ścieków. Przy wzroście natężenia odpływu ścieków z kanalizacji o 100%, ich temperatura może wzrosnąć w okresie zimowym o 1ºC, natomiast w letnim o 3ºC. W przypadku sieci kanalizacyjnych zakończonych długimi kolektorami tranzytowymi, niekorzystnemu skróceniu ulega czas trwania temperatury ścieków optymalnej w aspekcie usuwania związków biogennych, a przy tym jednocześnie wydłuża się czas trwania temperatury ścieków niekorzystnej dla ich biologicznego oczyszczania.
The aim of the research was to get the expertise, how location of wastewater treatment plant to basin of sewage system influences the temperature of inflowing wastewater. The analysis included four sewage systems, which are different for the sake of length of transit canal between treatment plant and residential buildings, in which domestic sewage was produced. In analysed systems sewage flew into the treatment plants with hydraulic capacity range from 100 to 300 m3·d-1, and with population equivalent less than 2000. Measurements of temperature of air and wastewater outflowing from sewage system, in analysed year 2012, were conducted continuously, with 1 hour interval, with use resistance sensors connected with data recorder. The research showed, that the distance of treatment plant to basin of sewage system has a significant impact on wastewater temperature outflowing from sewage system. In winter period mean daily wastewater temperature outflowing from transit manifolds with length from 300 to 600 m was lower even about 3ºC, but in summer period up to 8ºC, in comparison to transit manifolds with length less than 10 m. Moreover, it was proved that, apart from length of transit manifold, also intensity of wastewater flow has a significant impact on wastewater temperature flowing into the treatment plant. With increase of intensity of wastewater flow about 100%, its temperature can increase in winter period about 1ºC, and about 3ºC in summer period. In case of sewage systems ended with long transit manifold, the duration time of optimal sewage temperature in terms of biogenic compounds removal is unfavourable reduced, and at the same time the duration time of wastewater temperature unfavourable for its biological treatment is extended.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, II/2; 615-626
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary results of studies on the effects of organic fertilization and mulching on the growth of one-year old European larch (Larix decidua Mill.) seedlings and occurrence of soil mites under micro-sprinkler irrigation in two sylvan-natural regions of Poland
Autorzy:
Rolbiecki, R.
Rolbiecki, S.
Klimek, A.
Podsiadlo, C.
Powiązania:
https://bibliotekanauki.pl/articles/60215.pdf
Data publikacji:
2008
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
organic fertilization
mulching
plant growth
one-year-old plant
European larch
Larix decidua
seedling
occurrence
soil mite
mite
micro-sprinkler irrigation
Polska
forest region
sewage sludge
bark
sawdust
Acari
Oribatida
Opis:
The aim of the study was to determine the influence of organic fertilization and mulching on the seedling vigour of European larch (Larix decidua Mill.) and occurrence of soil mites (Acari) in forest- and post-arable soils. Two different nursery experiments were carried out in the vegetation period of the year 2005 on light soils at two sylvan-natural regions of Poland. The first trial was conducted at Białe Błota near Bydgoszcz – on a brown podzolic soil. The second experiment – at Lipnik near Stargard Szczeciński – on an acid brown soil. The higher was the rainfall amount during the vegetation period, the lower was the seasonal irrigation rate supplied to European larch seedlings. Because of this the seasonal irrigation water rate applied at Białe Błota was higher than that at Lipnik. European larch seedlings grown on the forest soil were characterized by the increased height and the fresh mass than those cultivated on the post-arable ground. Seedlings grown in the forest soil on treatments mulched with litter were characterized by the increased height and the fresh mass of above-ground parts as compared to those cultivated on control plots (without mulching). Mulching with litter increased the number of mites, especially oribatid mites, as well as their species diversity. It can be recognized as the result of the positive influence of the mulching on the biological properties of the studied soils.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2008, 06
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies