Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "heat distribution" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Analyzing temperature changes in the ground massif with a horizontal heat exchanger in the course of the heating season
Autorzy:
Adamovsky, R.
Neuberger, P.
Sed'ova, M.
Powiązania:
https://bibliotekanauki.pl/articles/62442.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
temperature change
ground massif
horizontal heat exchanger
heating season
heat pump
ground source heat pump
heat transfer
energy potential
ground temperature
temperature distribution
Opis:
The article is devoted to temperature changes in the ground massif with the horizontal heat exchanger as an energy source for a heat pump. The article was aimed at analyzing temperature changes in the ground massif with the horizontal heat exchanger at the beginning, in the course of and at the end of the heating season. Another aim was to analyze temperature differences in the area of the horizontal exchanger and the reference lot. The heat flow utilized in the evaporator of heat pump was extracted from the ground exchanger (nominal output at the condenser was 10.5 kW). Temperatures of the ground massif with the horizontal heat exchanger were measured in its plane in depths of 0.75 m, 0.5 m and 0.25 m. The temperature inside the ground massif on the reference lot and ambient parameters were measured as well. It is obvious that the difference of energetic potentials inside the ground massif with the heat exchanger and on the reference lot is insignificant at the beginning of the heating season. During the heating season, the difference of ground massif energetic potentials increases; at the end it is constant. The difference of temperatures in horizontal planes was not significant at the beginning of the heating season; however, it gradually increased. Maximum differences were detected in the area of the heat exchanger. In higher strata, the difference between temperatures decreases. During a major part of the heating season, temperatures at pipes of the ground exchanger were negative. This fact affected amounts of heat extracted from the ground massif.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2010, 11
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature changes in heat pump horizontal ground source
Autorzy:
Adamovsky, R.
Neuberger, P.
Sed'ova, M.
Powiązania:
https://bibliotekanauki.pl/articles/60337.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
temperature change
heat pump
ground massif
horizontal heat exchanger
heat potential
soil
thermal potential
heating period
ground temperature
temperature distribution
heat transfer
energy conservation
Opis:
The paper deals with assessment of thermal fields and temperature changes in ground massif with horizontal heat exchanger used as a heat source for a heat pump. Temperatures in the zone of the horizontal ground exchanger are compared with temperatures in a reference land. Changes of heat potential of the soil during the heating period are also assessed. Possibilities of recovery of thermal potential of the ground massif when utilizing vertical and horizontal exchangers are analyzed in the opening part of the paper. The results of the first verification indicated that average temperatures in the horizontal planes of the ground massif did not differ considerably with distance from the exchanger tube. Differences in average temperatures in reference and experimental lands confirmed sufficient heat potential of the ground massif even at the peak of the heating period. The differences in average temperatures reached up to 6.51 K in the end of the heating period while at the beginning of the heating period, the differences in average temperatures dropped to 1.35 K. The differences between maximum and minimum temperatures in the zone of the ground exchanger reached up to 1.9 K at the peak of the heating period and rose to 3.9 K at the beginning and end of the heating period. The first results of our measurements indicate the necessity of accumulation of thermal energy in the soil massif in the summer period like in case of the vertical exchangers.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2009, 07
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies