Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "vitaliy" wg kryterium: Wszystkie pola


Wyświetlanie 1-3 z 3
Tytuł:
Laboratory bench to analyze of automatic control system with a fuzzy controller
Autorzy:
Tryputen, Mykola
Kuznetsov, Vitaliy
Kuznetsov, Valeriy
Kuznetsova, Yevheniia
Tryputen, Maksym
Kuznetsova, Alisa
Powiązania:
https://bibliotekanauki.pl/articles/328426.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
laboratory bench
thermal objects
hardware-software complex
programmable logical controller
dynamic model
system sterowania
stanowisko laboratoryjne
model dynamiczny
sterownik
Opis:
The paper represents laboratory bench to analyse a system of automated control with a fuzzy controller. The laboratory bench consists of a thermal object, and software and hardware complex involving logic controller VIPA System 200 V as well as HMI / SCADA system Zenon Supervisor 7.0. The thermal object is described with the help of the second-order differential equation using “current value within the power converter of electric heater-air temperature inside a thermal object” control channel. Coefficients of the differential equation depend upon location of a dampener and upon rotation frequency of a centrifugal fan. Control error (ie deviation between the specified temperature value within the thermal object and its current value), and derivative of the error, represented in the form of linguistic variables involving five triangular terms and two trapezoidal (extreme) ones have been used as the input values of the fuzzy controller. Output value of the fuzzy controller is the electric power supplied to the electric heater and assuming seven specified values. Selection of the specific value of electric power depends upon knowledge base being a finite set of rules of fuzzy sets falling into line with the applied linguistic variables. To implement such a system of automated control with a fuzzy controller, original software has been developed making it possible to analyze a process of thermal object heating with the use of human-computer interface. Interaction algorithm of certain program elements has been described. Experimental results, concerning the thermal object transfer from different initial conditions to terminal ones, have been demonstrated. A dependence of mean-square error of the controlled value upon the control period has been demonstrated.
Źródło:
Diagnostyka; 2020, 21, 2; 61-68
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preventing the development of emergency modes of interlocked electric drives of a rolling mill under the impact loads
Autorzy:
Druzhinin, Valeriy
Sivyakova, Galina
Kalinin, Alexey
Tytiuk, Valerii
Nikolenko, Anatolii
Kuznetsov, Vitaliy Vadimovich
Kuzmenko, Mykhailo
Powiązania:
https://bibliotekanauki.pl/articles/2174475.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
power supply network
voltage drops
electric drive
hot rolling mill
mathematical modeling
simulation modeling
sieć zasilająca
spadki napięcia
napęd elektryczny
modelowanie matematyczne
modelowanie symulacyjne
Opis:
In recent years, due to the tightening of competition in the global market of steel producers, the requirements for the quality of hot-rolled steel have increased. The finishing group of the rolling mill is characterized by a complex structure of mechanical and electrical parts. The operation of electric drive systems of such units is characterized by the interrelation of electromagnetic processes, mechanical phenomena and technological factors. As experimental studies have shown, the quality of the supply voltage is inextricably linked with the impact nature of the loads in the rolling stands of the roughing and finishing groups of the hot rolling mill. A decrease in the supply voltage may be accompanied by the development of emergency modes of synchronous electric drives, leading to a decrease in the quality of the finished product.The paper developed a mathematical model of the power supply system of the rolling mill JSC "ArcelorMittal Temirtau". It is shown that this can lead to loss of synchronism of the synchronous motor. Such a voltage drop has a significant impact on the operation of DC electric drives of the finishing group. Various strategies are proposed to counter the development of emergency situations.
Źródło:
Diagnostyka; 2023, 24, 1; art. no. 2023105
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the neutral grounding modes influence on the reliability characteristics of local systems with renewable energy sources
Autorzy:
Ostapchuk, Oleksandr
Kuznetsov, Valeriy
Kruczek, Włodzimierz
Kuznetsov, Vitaliy
Tsyplenkov, Dmytro
Powiązania:
https://bibliotekanauki.pl/articles/1840882.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
electric networks
protection
reliability
ground failure current
electrical safety
system with isolated neutral
system with resonant grounding
system with low-impedance neutral grounding
sieć elektryczna
ochrona
niezawodność
bezpieczeństwo
Opis:
When comparing the performance indicators of electrical networks with different types of neutral grounding, along with the fulfilment of the requirement to ensure reliability of power supply to consumers, serious attention is drawn to the main network parameters influencing the performance of power supply systems. Analysis of research and its results, reported above, on the influence of the neutral ground of power networks on the reliability and electrical safety conditions of the power supply systems as a whole, on the damage of distribution networks and electrical equipment as well as on the working capacity of relay protection devices, provides an opportunity to estimate each specific operation mode of the neutral and to develop recommendations aimed at strengthening the positive indicators of the corresponding modes. Other things being equal, reliability of power supply to electrical receivers or reliability of distribution networks is mainly determined by the damage to network elements and the performance of relay protection devices. The degree of influence of these factors on the reliability of distribution networks depends on the neutral mode, which in turn determines the level of internal overvoltages and the nature of transient processes at earth fault.
Źródło:
Diagnostyka; 2021, 22, 1; 45-56
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies