Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "hydraulic efficiency" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Experimental testing of the influence of the operating loading on the flow characteristics of hydraulic pump
Autorzy:
Kosiba, Ján
Tkáč, Zdenko
Jablonický, Juraj
Shcherbak, Valeriia
Ganushchak-Yefimenko, Liudmyla
Paumer, Martin
Bukoros, Tetiana
Čurgaliová, Gabriela
Zachar, Martin
Powiązania:
https://bibliotekanauki.pl/articles/2175138.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
hydraulics
hydraulic device
flow efficiency
Opis:
The contribution deals with the influence of the operating loading on the flow characteristics of the hydraulic pump under laboratory conditions. In the test, a new toothed hydraulic pump and hydraulic oil with kinematic viscosity at 40°C, ν = 64.2 mm2.s-1 were used. The operational loading was measured during the most difficult agrotechnical operation – ploughing, at which the loading of the hydraulic pump is the greatest. Laboratory testing was determined for 200 hours, and the flow characteristics had been detected at 50 hours intervals. Measurement of the flow characteristics was performed at rated speed n = 1,000 rpm. Measurement of the flow characteristics was carried out in dependence on the loading pressure from p = 0 MPa to p = 20 MPa. When p = 0 MPa, the value reached n = 91.70% and when p = 20 MPa, n = 86.68%. Running-in of the hydraulic pump lasted 150 hours, with an increase of the flow characteristics Δηvol = 1.36% (p = 10 MPa) compared to the initial state. After working for 200 hours, the flow rate of the hydraulic pump decreases compared to 150 hours.
Źródło:
Eksploatacja i Niezawodność; 2022, 24, 3; 583--589
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of the influence of hydraulic oil temperature on the variable-speed pump performance
Autorzy:
Stawiński, Łukasz
Kosucki, Andrzej
Cebulak, Maciej
Górniak vel Górski, Adrian
Grala, Mikołaj
Powiązania:
https://bibliotekanauki.pl/articles/2087011.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
hydraulic pump
volumetric efficiency
temperature-dependent characteristics
variable speed drive
hydraulic oil
Opis:
This paper describes investigation on the influence of hydraulic oil temperature on the performance of a hydraulic pump. The aim of the research is to determine changes in volumetric efficiency of the pump in the form of maps of operation at different temperatures of the hydraulic oil, in conditions of variable speed and pressure. The described tests were carried out on an experimental stand with a hydraulic fixed-displacement gear pump controlled by a servo motor. Based on the signals from the sensors processed with the LabVIEW program, maps of the hydraulic pump operation were drown in a wide range of speeds and temperatures. The paper presents the results of the research and based on this the conclusions regarding the main aim of the research and others that were observed during the measurements were presented. The most important conclusion from the study shows that the temperature-dependent characteristics provide users with a significant amount of information such as operating conditions that will ensure a high level of efficiency.
Źródło:
Eksploatacja i Niezawodność; 2022, 24, 2; 289--296
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of pressure drop on the working volume of a hydraulic motor
Autorzy:
Śliwiński, Pawel
Powiązania:
https://bibliotekanauki.pl/articles/2200940.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
theoretical working volume
actual working volume
hydraulic motor
satellite
motor
volumetric efficiency
mechanical efficiency
Opis:
Reliability and maintenance analysis of hydraulic positive machines basicly focused on the processes of their wear and failure. But in order to correctly assess the mechanical and volumetric efficiency of a hydraulic motor, both at the stage of development research or at the stage of control tests during its exploitation, the working volume of this motor must be correctly determined. Therefore this paper proposes a new method of assessment of the size of the working volume of a hydraulic motor. It has been shown that the hydraulic motor absorbency per one revolution of this motor shaft is a non-linear function of pressure drop in working mechanism of the motor and non-linear function of motor rotational speed. Thus the relation between the working volume of a hydraulic motor and the pressure drop in the motor working mechanism is a non-linear function. This working volume as a funcition of pressure drop has been called the actual working volume. The correctness of the proposed method was confirmed experimentally.
Źródło:
Eksploatacja i Niezawodność; 2022, 24, 4; 747--757
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the influence of hydraulic fluid quality on external gear pump performance
Autorzy:
Novaković, Borivoj
Radovanović, Ljiljana
Zuber, Ninoslav
Radosav, Dragica
Đorđević, Luka
Kavalić, Mila
Powiązania:
https://bibliotekanauki.pl/articles/2087006.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
hydraulic system
press
fluid
oil
degradation
filtration
external gear pump
measurement
efficiency
Opis:
The basis of every hydraulic system is based on energy transformations, which are realized through hydraulic working fluid. Hydraulic oils are certainly subject to changes within their structure, meaning the basic characteristics and parameters of hydraulic oil, such as density, viscosity, humidity. The oils that are exploited are exposed to the process of degradation, which largely leads to significantly poorer quality of hydraulic fluid. The paper deals with the influence of changes in the characteristics of the hydraulic fluid on the hydraulic operating parameters of the gear pump installed on the hydraulic press. The parameters refer to pressure, flow, and temperature, as well as the quality of hydraulic oil, which affects the volumetric efficiency of the pump, and the results presented in the conclusion are based on the measured values of parameters before and after corrective measures. The control of parameters aims to increase the efficiency and reliability of the hydraulic system, a way of modern detection of deviations of parameters from standard, required values.
Źródło:
Eksploatacja i Niezawodność; 2022, 24, 2; 260--268
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reliability modeling based on power transfer efficiency and its application to aircraft actuation system
Model niezawodności oparty na wydajności przesyłu energii i jego zastosowanie do oceny lotniczego układu hydrauliki siłowej
Autorzy:
Cui, Xiaoyu
Li, Tongyang
Wang, Shaoping
Shi, Jian
Ma, Zhonghai
Powiązania:
https://bibliotekanauki.pl/articles/946137.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
reliability modeling
power transfer efficiency
multi-state performance
dual hydraulic actuation system
generalized stochastic Petri nets
universal generating function
modelowanie niezawodności
wydajność przesyłu energii
działanie systemu wielostanowego
podwójny układ hydrauliki siłowej
uogólnione stochastyczne sieci Petriego
uniwersalna funkcja tworząca
Opis:
The power transfer systems (PTS) has special reliability properties, including multiple states and fault dependence. Consequently, traditional binary-state reliability modeling methods cannot accurately evaluate the reliability of PTS. In order to resolve the contradiction between terminal energy demand and power transfer capability of PTS, this paper proposes a novel multi-state reliability model based on power transfer efficiency (PTE) for reliability evaluation of PTS. The multi-state model caused by performance degradation based on PTE is considered in this paper. In addition, the failure correlation in virtue of the system structure and energy allocation mechanism is analyzed in the proposed model, and the corresponding reliability evaluation result is obtained under different terminal energy requirements. The approach is verified on the example of a dual hydraulic actuation system (DHAS), in which the stochastic model based on the generalized stochastic Petri nets (GSPNs) is established and combined with the power transfer capability via universal generating function (UGF). Though changing flow rate to face the degradation rate of hydraulic pump, the reliability assessment of DHAS based on the proposed reliability model is effective and accurate.
Układy przesyłu energii (power transfer systems, PTS) charakteryzują się szczególnymi właściwościami niezawodnościowymi, w tym wielostanowością i zależnością między błędami. W związku z tym, tradycyjne metody modelowania niezawodności, które sprawdzają się w przypadku systemów dwustanowych, nie pozwalają na dokładną ocenę niezawodności PTS. W przedstawionej pracy zaproponowano nowatorski model niezawodności systemu wielostanowego, który do oceny niezawodności PTS wykorzystuje dane o wydajności przesyłu energii (PTE). Model ten wiążę niezawodność zarówno z zapotrzebowaniem na energię końcową jak i zdolnością przesyłową PTS. Rozważano model wielostanowy opisujący proces degradacji komponentów systemu w oparciu o PTE. W proponowanym modelu analizowano korelacje między uszkodzeniami w świetle struktury systemu i mechanizmu alokacji energii, a niezawodność oceniano dla różnych stopni zapotrzebowania na energię końcową. Podejście to zweryfikowano na przykładzie podwójnego układu hydrauliki siłowej (DHAS), dla którego ustalono model stochastyczny oparty na uogólnionych stochastycznych sieciach Petriego (GSPN), który łączono ze zdolnością przesyłową za pomocą uniwersalnej funkcji tworzącej (UGF). Badania pompy hydraulicznej prowadzone dla różnych prędkości przepływu i różnych szybkości degradacji wykazały, iż ocena niezawodności DHAS na podstawie proponowanego modelu cechuje się skutecznością i trafnością.
Źródło:
Eksploatacja i Niezawodność; 2020, 22, 2; 282-296
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies