Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "43.35.Yb" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Non-Contact Interaction of Ultrasonic Wave on Laser Beam
Autorzy:
Muc, S.
Gudra, T.
Bereś-Pawlik, E.
Powiązania:
https://bibliotekanauki.pl/articles/1493252.pdf
Data publikacji:
2011-10
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.35.Yb
42.81.Wg
Opis:
The article presents the results of Matlab simulations and experimental studies of non-contact influence of ultrasonic wave on laser beam. A role of the air-gap and the influence of the air-gap on laser-ultrasonic transmission in optical fiber were examined. Two optical fibers were used with air-gap between them. One fiber was attached to a laser diode and positioned to pass through a hole in a sandwich type transducer and in a velocity transformer. In the velocity transformer (at its end), after leaving small air-gap, to the end of the transformer, the other optical fiber is attached. The second fiber can interact with a given biological structure.
Źródło:
Acta Physica Polonica A; 2011, 120, 4; 702-704
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Possibility of a Simultaneous Transmission οf Ultrasound and Laser Radiation via Flexible Optical Silica Glass Fibre
Autorzy:
Muc, S.
Gudra, T.
Beres-Pawlik, E.
Powiązania:
https://bibliotekanauki.pl/articles/1807739.pdf
Data publikacji:
2009-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.35.Yb
42.81.Wg
Opis:
Glass optical fibres are a promising medium for simultaneous laser-ultrasonic applications. The proposed application system is based on simultaneous transmission of laser radiation and ultrasounds in a flexible silica glass fibre. The optical fibre's core was made of $SiO_2$ (97%) and $GeO_2$ (3%) and the cladding was 100% $SiO_2$. The material the optical fibre is made of enables simultaneous transmission of laser radiation and ultrasonic wave. Experiments were performed using a Mach-Zehnder optical waveguide interferometer with single-mode optical fibre coupler. This paper presents measurement results for delivering ultrasonic waves to the optical fibre using longitudinal vibrations generated by a sandwich ultrasonic transducer with a velocity transformer. The study presents the relations concerning simultaneous operation of both types of waves and the possibilities of transmission of low frequency, high power ultrasonic wave in optical fibres using a sandwich type transducer.
Źródło:
Acta Physica Polonica A; 2009, 116, 3; 359-362
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Application of Ultrasonic Methods to Flow Measurement and Detection of Microembolus in Heart Prostheses
Autorzy:
Gawlikowski, M.
Lewandowski, M.
Nowicki, A.
Kustosz, R.
Walczak, M.
Karwat, P.
Karłowicz, P.
Powiązania:
https://bibliotekanauki.pl/articles/1399342.pdf
Data publikacji:
2013-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.35.Yb
43.80.Qf
43.35.Ae
Opis:
For the last 20 years the world cardiosurgery has presented a considerable change of attitude to mechanical circulatory support. In spite of technological progress the main problems in ventricular assist devices are: thrombosis and low accuracy of flow measurements. In this paper the prototype of multi-gate Doppler flowmeter intended for cardiac assist system ReligaHeart EXT has been presented as well as the possibility of ultrasonic microembolus detection.
Źródło:
Acta Physica Polonica A; 2013, 124, 3; 417-420
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An Optical Hydrophone for the Single-Shot Field Measurements of High Power Pressure Pulse Fields
Autorzy:
Jamshidi-Rad, A.
Ueberle, F.
Powiązania:
https://bibliotekanauki.pl/articles/1383349.pdf
Data publikacji:
2015-01
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
06.20.-f
42.25.Fx
43.35.Sx
43.35.Yb
Opis:
The measurements of ultrasonic fields are often performed using polyvinylidene fluoride (PVDF) membrane hydrophones. Recently, optical hydrophones have gained popularity. Refractive type optical hydrophones are based on the change of refractive index at a glass-water interface when the shockwave passes the sensitive area. A major disadvantage of the optical and the PVDF hydrophones is the fact that they provide a single spot sensitive area, with the result that field measurements need a repositioning of the probe. In this work we introduce a multi-spot optical hydrophone with six measurement spots, for the single shot field measurement of shockwave fields. We measure a highly stable shockwave source with a calibrated hydrophone and the multi-spot optical hydrophone and we find good agreement for the calculated energy values of the shockwave field (depending on the energy settings 4% ± 1%).
Źródło:
Acta Physica Polonica A; 2015, 127, 1; 69-71
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrasonic Non-Invasive Method for Relative Changes Measurements of Intima-Media Thickness in Artery Walls
Autorzy:
Trawiński, Z.
Wójcik, J.
Powałowski, T.
Gutkiewicz, P.
Powiązania:
https://bibliotekanauki.pl/articles/1811556.pdf
Data publikacji:
2008-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.25.Ed
43.25.Zx
43.35.Yb
43.35.Bf
43.38.Fx
43.58.Ta
43.60.Tj
Opis:
The aim of this paper is to present the new method for relative changes measurements of intima-media thickness in the common carotid artery wall. The numerical solver was created for calculation of the fields of ultrasonic beams and scattered fields under different boundary conditions and different angles of penetration of ultrasonic beams with respect to the position of the arterial wall. The cylindrical model of the artery was changing the radius and thickness of the wall under cyclic variation of blood pressure. The presented method was verified on a pipe made of latex. The paper describes also the initial results of examinations of the intima-media thickness. The good agreement for the angle dependence and the perpendicular ultrasonic beam displacement from the longitudinal axis of the artery segment between the numerical calculation and experimental results was obtained for different artery diameters.
Źródło:
Acta Physica Polonica A; 2008, 114, 6A; A-243-A-247
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies