Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Pawlowski, J." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
EPR Spectra of Multispin Systems. Application to Poly-m-p-Aniline
Autorzy:
Juszyński, P.
Twardowski, A.
Gosk, J.
Kulszewicz-Bajer, I.
Pawłowski, M.
Dziatkowski, K.
Szczytko, J.
Powiązania:
https://bibliotekanauki.pl/articles/2048138.pdf
Data publikacji:
2011-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
02.70.-c
75.10.-b
Opis:
In this communication we present NiceMagnetic, software for simulations and analysis of EPR spectrum and SQUID measurements. Systems of arbitrary number N of spin-only magnetic moments (S ≤ 0 and L = 0) were considered within the lines of the Heisenberg and Zeeman Hamiltonians. Effective algorithms used for the computations are discussed. This includes modified secant method adapted to calculate resonance fields with demanded precision. Finally, application of NiceMagnetic to experimental SQUID magnetization and EPR spectra of poly-m-p-aniline, one of recently synthesized high spin polymers containing unpaired electrons will be presented. As a result, exchange integral between electron and nitrogen nuclei spins (ligand hyperfine interaction) J = 6.3 × 10$\text{}^{-4}$ cm$\text{}^{-1}$ was estimated.
Źródło:
Acta Physica Polonica A; 2011, 119, 5; 717-719
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sputtering and Implantation of VV-6025X Surface with Slow Heavy Ions Monitored with PIXE
Autorzy:
Antoszewska, M.
Balcerski, J.
Brzozowski, R.
Dolecki, K.
Frątczak, E.
Gwizdałła, T.
Pawłowski, B.
Moneta, M.
Powiązania:
https://bibliotekanauki.pl/articles/1367499.pdf
Data publikacji:
2014-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
34.35.+a
61.80.Lj
Opis:
In this work the characteristic radiation, emitted during interaction of medium energy (200 keV) ambient heavy ions (Ar) with $Fe_{4}Co_{66}Si_{12}B_{14}Nb_{1}Mo_{2}Cu_{1}$ (VV-6025X) amorphous alloy, was measured in grazing incident-exit angle geometry and in time sequence, in order to determine dynamics of formation of subsurface region, damaged through implantation, sputtering and interface mixing. It was shown that structure and composition of surface is unstable against heavy ions irradiation due to preferential sputtering and implantation of ions, and recoils, and that the dynamics of such modification can be monitored in-situ with particle induced X-ray emission (PIXE) method.
Źródło:
Acta Physica Polonica A; 2014, 126, 1; 136-137
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mn Impurity in Bulk GaAs Crystals
Autorzy:
Pawłowski, M.
Piersa, M.
Wołoś, A.
Palczewska, M.
Strzelecka, G.
Hruban, A.
Gosk, J.
Kamińska, M.
Twardowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/2044520.pdf
Data publikacji:
2005-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
71.55.Eq
72.20.Ee
75.50.Pp
76.30.Fc
Opis:
Magnetic and electron transport properties of GaAs:Mn crystals grown by Czochralski method were studied. Electron spin resonance showed the presence of Mn acceptor A in two charge states: singly ionized A$\text{}^{-}$ in the form of Mn$\text{}^{2+}$(d$\text{}^{5}$), and neutral A$\text{}^{0}$ in the form of Mn$\text{}^{2+}$(d$\text{}^{5}$) plus a bound hole (h). It was possible to determine the relative concentration of both types of centers from intensity of the corresponding electron spin resonance lines. Magnetization measured as a function of magnetic field (up to 6 T) in the temperature range of 2-300 K revealed overall paramagnetic behavior of the samples. Effective spin was found to be about 1.5 value, which was consistent with the presence of two types of Mn configurations. In most of the studied samples the dominance of Mn$\text{}^{2+}$(d$\text{}^{5}$)+h configuration was established and it increased after annealing of native donors. The total value of Mn content was obtained from fitting of magnetization curves with the use of parameters obtained from electron spin resonance. In electron transport, two mechanisms of conductivity were observed: valence band transport dominated above 70 K, and hopping conductivity within Mn impurity band at lower temperatures. From the analysis of the hopping conductivity and using the obtained values of the total Mn content, the effective radius of Mn acceptor in GaAs was estimated as a = 11±3Å.
Źródło:
Acta Physica Polonica A; 2005, 108, 5; 825-830
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Capillary Microfluidic Sensor for Determining the Most Fertile Period in Cows
Autorzy:
Borecki, M.
Korwin-Pawlowski, M.
Bebłowska, M.
Szmidt, M.
Urbańska, K.
Kalenik, J.
Chudzian, Ł.
Szczepański, Z.
Kopczyński, K.
Jakubowski, A.
Szmidt, A.
Powiązania:
https://bibliotekanauki.pl/articles/1506725.pdf
Data publikacji:
2010-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.81.Pa
87.85.fk
47.35.Pq
07.05.Mh
Opis:
This paper presents a new method of optoelectronic determination of cow fertility, based on a microfluidic fiber-optic capillary sensor. The current state of the art of fiber-optic capillary sensors is discussed briefly along with aspects of instrumentation and applications. Unlike classical fiber-optic sensors which are based on changes in light propagation inside the fiber in response to external conditions, optical capillary sensors rely on changes of light transmission within capillaries filled with the liquid to be analyzed. This approach opens up interesting new possibilities for the application of capillary microfluidic sensors, while raising specific issues relating to their construction, materials and technology. The investigated sensor uses light switching forced by local heating in a capillary filled with bovine vaginal fluid. The dynamically recorded data were processed in an artificial neural network. We were able to observe changes in the cow's fertility cycle allowing us to identify when an individual cow was in the middle part of standing estrus which is most situated for insemination.
Źródło:
Acta Physica Polonica A; 2010, 118, 6; 1093-1099
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies