Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Gacek, Z." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Properties of Acoustic Emission Signals Coming from Partial Discharges Caused by Modeled Sources Immersed in Transformer Oil
Autorzy:
Witos, F.
Gacek, Z.
Powiązania:
https://bibliotekanauki.pl/articles/1807759.pdf
Data publikacji:
2009-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.Le
52.80.-s
77.22.Jp
84.70.+p
Opis:
Investigation results concerning acoustic emission signals coming from partial discharges generated by modeled sources are presented in the paper. These sources have been made using different bushing ends (without any extra elements and with a thread or a pike) situated directly in the oil, but without screens typical for partial discharge investigations in a bushing. Measurements have been carried out using own measuring acoustic emission system DEMA-COMP and - in a parallel way - computer-aided partial discharges measuring system TE 571 (produced by the firm Haefely Trench). Fundamental and advanced analysis of acoustic emission signals has been made. These signals were recorded in 20 measuring situations which need to multiple installation of acoustic emission sensors. Conclusions resultant from own originate advanced analysis of signals content description of properties revealed by defined acoustic emission descriptors.
Źródło:
Acta Physica Polonica A; 2009, 116, 3; 422-427
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testing of Partial Discharges in Generator Coil Bars with the Help of Calibrated Acoustic Emission Method
Autorzy:
Witos, F.
Gacek, Z.
Opilski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/1811569.pdf
Data publikacji:
2008-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.Le
43.60.Lg
52.80.s
77.22.Jp
84.70.+p
Opis:
Investigation results of acoustic emission signals coming from partial discharges within chosen generator coil bar, in relation to measurement results of apparent charge introduced by partial discharges sources, are presented in the article. Analysis is based on amplitude distributions calculated for acoustic emission signals, ordered at different measuring points for different values of the supply voltage. In order to assign acoustic emission signal to its advance degree a descriptor named by an acronym ADP (defined by authors) is calculated for each amplitude distribution. Descriptor families describing acoustic emission signals measured at particular measuring points (for different supply voltages) are presented in relation to apparent charge introduced by acoustic emission sources. These families concerning acoustic emission signals, measured at different measuring points for identical supply voltage, enable us to locate acoustic emission sources with maximum activity.
Źródło:
Acta Physica Polonica A; 2008, 114, 6A; A-249-A-258
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Anusual Application of Partial Discharges to Diagnose of High Voltage Power Transformers
Autorzy:
Gacek, Z.
Szadkowski, M.
Malitowski, G.
Witos, F.
Olszewska, A.
Powiązania:
https://bibliotekanauki.pl/articles/1493101.pdf
Data publikacji:
2011-10
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.Le
52.80.s
07.50.Hp
Opis:
The article contains information on research carried out in Electric Faculty of Silesian University of Technology, made at test stations and aimed at diagnosis how is actual technical state of high voltage power oil transformers. Opinion on a state of transformers is based on analysis results of partial discharge measurements. Authors use simultaneously: electric, acoustic and dissolved gas analysis method. Applied acoustic method is the original own one. Non-conventional application of electric method is proposed, too. In the frame of chosen methodology the partial discharges are measured and next calculations of quantities describing partial discharges within particular methods are carried out in order to describe phenomena commonly for electric and acoustic method. Information sources about level and kind of partial discharges are measurement results obtained from electric method whereas information on places where partial discharges appear is contained in measurement results coming from acoustic method. Authors present selected application results of such a combined measuring method.
Źródło:
Acta Physica Polonica A; 2011, 120, 4; 609-615
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Results of Experiments with Fiber Pressure Sensor Applied in the Polish Artificial Heart Prosthesis
Autorzy:
Konieczny, G.
Opilski, Z.
Pustelny, T.
Gacek, A.
Gibinski, P.
Kustosz, R.
Powiązania:
https://bibliotekanauki.pl/articles/1506799.pdf
Data publikacji:
2010-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.79.-e
42.81.-i
07.07.Df
47.63.Cb
Opis:
The following paper introduces the problem of noninvasive pressure measurements in Polish artificial heart prosthesis. The pressure sensor is proposed and introduced, and preliminary tests are shown. The paper deals with the proposed sensing elements, requirement noninvasive solution and preliminary tests of polyurethane membrane transmission. The paper includes also experimental results of a fiber pressure sensor introducing noninvasive pressure measurements with pressure transmission through a polyurethane tube wall.
Źródło:
Acta Physica Polonica A; 2010, 118, 6; 1183-1185
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies