Tytuł:
State of the Work Diagram of the Artificial Heart
Autorzy:
Konieczny, G.
Opilski, Z.
Pustelny, T.
Maciak, E.
Powiązania:
https://bibliotekanauki.pl/articles/1807734.pdf
Data publikacji:
2009-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.79.-e
42.81.-i
07.07.Df
47.63.Cb
Opis:
This paper presents the results of investigations on novel pressure measurement methods to be for used in the project "Polish Artificial Heart". The investigations concerned possible pressure sensors for noninvasive blood pressure measurements in selected points around the pneumatic ventricular assist device (POLVAD). The fiber pressure sensor and the possibility of pressure measurements with piezofoils were tested. The paper includes preliminary results and development plans.
Źródło:
Acta Physica Polonica A; 2009, 116, 3; 344-347
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigations of SAW Structures with Oxide Graphene Layer to Detection of Selected Gases
Autorzy:
Drewniak, S.
Pustelny, T.
Setkiewicz, M.
Maciak, E.
Urbańczyk, M.
Procek, M.
Opilski, Z.
Jagiello, J.
Lipinska, L.
Powiązania:
https://bibliotekanauki.pl/articles/1399339.pdf
Data publikacji:
2013-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.81.Pa
82.47.Rs
07.07.Df
Opis:
In this paper we present the results of investigations of graphene oxide layers using the SAW structure (structure with surface acoustic wave propagated) exposed to the affect of low concentrations of hydrogen and nitrogen dioxide in synthetic air. During the measurements, the differential signal (from two measuring channels) was recorded. The sensing graphene oxide layer was deposited only on first channel, whereas the second channel was not covered by any additional layer. The tests were made with various concentrations of the analyzed gases and at various temperatures of the sensing structure during the measurements. Analyses were performed with special emphasis on the time response of the sensor structure to changes in the gas atmosphere.
Źródło:
Acta Physica Polonica A; 2013, 124, 3; 402-405
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bilayer Structures of $NiO_{x}$ and Pd in Surface Acoustic Wave and Electrical Gas Sensor Systems
Autorzy:
Jakubik, W.
Urbańczyk, M.
Maciak, E.
Pustelny, T.
Powiązania:
https://bibliotekanauki.pl/articles/1795797.pdf
Data publikacji:
2009-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.25.Fe
77.65.Dq
43.35.Pt
68.35.Iv
07.07.Df
Opis:
A bilayer sensor structure of nickel oxide $NiO_x$ ( ≈ 60 nm) with a very thin film of palladium (Pd ≈ 18 nm) on the top, has been studied for gas-sensing application at relatively low temperatures of about 30°C and 60°C. The bilayer structure was obtained by rf sputtering and by vacuum deposition (first the $NiO_{x}$ and then the Pd film) onto a $LiNbO_{3}$ Y-cut Z-propagating substrate, making use of the surface acoustic wave method, and additionally (in the same technological processes) onto a glass substrate with a planar microelectrode array for simultaneous monitoring of the planar resistance of the layered structure. Such a bilayer structure was investigated in a low concentration range (from 50 ppm to 400 ppm in air) of nitrogen dioxide $(NO_{2})$, carbon monoxide (CO) and ammonia $(NH_{3})$ in a dry and wet air atmosphere and in a medium hydrogen concentration (1-2.5%) in dry air. The $NiO_{x}$ and Pd bilayer structure interact rather weakly with $NO_{2}$ molecules but with CO and $NH_{3}$ this interaction is much greater, especially at higher temperature ( ≈ 60°C). The hydrogen sensitivity is on the medium level, not exceeding 600 Hz (relative change in the differential frequency of ≈ 2.3%) at interaction temperature of 35°C.
Źródło:
Acta Physica Polonica A; 2009, 116, 3; 315-320
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of Humidity on the Resistance Structures with Graphene Sensor Layer
Autorzy:
Pustelny, T.
Setkiewicz, M.
Drewniak, S.
Maciak, E.
Stolarczyk, A.
Procek, M.
Urbańczyk, M.
Gut, K.
Opilski, Z.
Pasternak, I.
Strupinski, W.
Powiązania:
https://bibliotekanauki.pl/articles/1418032.pdf
Data publikacji:
2012-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.07.Df
42.81.Pa
82.47.Rs
Opis:
In the paper the results of investigations are presented concerning the influence of humidity of air on the resistance of a gas sensor structure with a graphene layer. The affects of nitrogen dioxide and humidity action on graphene were studied. We indicated that humidity might play an important role in determining the gas sensing properties of the graphene layer. In the paper it has been shown that in the case of a nitrogen oxide sensor, the reaction of $NO_2$ with water vapour can generate permanent defects in graphene.
Źródło:
Acta Physica Polonica A; 2012, 122, 5; 870-873
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies