Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "turbine generator" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Automatic identification of malfunctions of large turbomachinery during transient states with genetic algorithm optimization
Autorzy:
Barszcz, Tomasz
Zabaryłło, Mateusz
Powiązania:
https://bibliotekanauki.pl/articles/2052104.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
machine learning
fault detection
transient
turbine generator
genetic algorithm
Opis:
Turbines and generators operating in the power generation industry are a major source of electrical energy worldwide. These are critical machines and their malfunctions should be detected in advance in order to avoid catastrophic failures and unplanned shutdowns. A maintenance strategy which enables to detect malfunctions at early stages of their existence plays a crucial role in facilities using such types of machinery. The best source of data applied for assessment of the technical condition are the transient data measured during start-ups and coast-downs. Most of the proposed methods using signal decomposition are applied to small machines with a rolling element bearing in steady-state operation with a shaft considered as a rigid body. The machines examined in the authors’ research operate above their first critical rotational speed interval and thus their shafts are considered to be flexible and are equipped with a hydrodynamic sliding bearing. Such an arrangement introduces significant complexity to the analysis of the machine behavior, and consequently, analyzing such data requires a highly skilled human expert. The main novelty proposed in the paper is the decomposition of transient vibration data into components responsible for particular failure modes. The method is automated and can be used for identification of turbogenerator malfunctions. Each parameter of a particular decomposed function has its physical representation and can help the maintenance staff to operate the machine properly. The parameters can also be used by the managing personnel to plan overhauls more precisely. The method has been validated on real-life data originating from a 200 MW class turbine. The real-life field data, along with the data generated by means of the commercial software utilized in GE’s engineering department for this particular class of machines, was used as the reference data set for an unbalanced response during the transients in question.
Źródło:
Metrology and Measurement Systems; 2022, 29, 1; 175-190
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Eddy current density asymmetric distribution of damper bars in bulb tubular turbine generator
Autorzy:
Qiu, H.
Fan, X.
Yi, R.
Feng, J.
Wu, J.
YANG, C.
ZHAO, H.
Powiązania:
https://bibliotekanauki.pl/articles/140467.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
damper bars
bulb tubular turbine generator
electromagnetic field
eddy current
Opis:
The major reasons that cause the damage of damper bars in the leeward side are found in this paper. It provides a route for the structure optimization design of a hydro generator. Firstly, capacity of a 24 MW bulb tubular turbine generator is taken as an example in this paper. The transient electromagnetic field model is established, and the correctness of the model is verified by the comparison of experimental results and simulation data. Secondly, when the generator is operated at rated condition, the eddy current density distributions of damper bars are studied. And the asymmetric phenomenon of the eddy current density on damper bars is discovered. The change laws of the eddy currents in damper bars are determined through further analysis. Thirdly, through the study of eddy current distributions under different conditions, it is confirmed that the stator slots and armature reaction are the main factors to affect the asymmetric distribution of the eddy current in damper bars. Finally, the studies of the magnetic density distribution and theoretical analysis revealed the asymmetric distribution mechanism of eddy current density.
Źródło:
Archives of Electrical Engineering; 2017, 66, 3; 571-581
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
3D loss and heat analysis at the end region of 4-poles 1150 MW nuclear power turbine generator
Autorzy:
Zhou, G.
Han, L.
Fan, Z
Liao, Y.
Huang, S.
Powiązania:
https://bibliotekanauki.pl/articles/950663.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
loss and heat
end region
4-poles nuclear power turbine generator
electromagnetic field
temperature field
Opis:
To study the principle of loss and heat at the end region of large 4-poles nuclear power turbine generator, 3D transient electromagnetic field and 3D steady temperature field finite element (FE) models of the end region are established respectively. Considering the factors such as rotor motion, core non-linearity and time-varying of electromagnetic field, the anisotropic heat conductivity and different heat dissipation conditions of stator end region, a 50 Hz, 1150 MW, 4-poles nuclear power turbine generator is investigated. The loss and heat at the generator end region are calculated respectively at no-load and rated-load, and the calculation results are compared with the test data. The result shows that the calculation model is accurate and the generator design is suitable. The method is valuable for the research of loss and heat at the end region of large 4-poles nuclear power turbine generator and the improvement of the generator’s operation stability. The method has been applied successfully for the design of the larger nuclear power turbine generators.
Źródło:
Archives of Electrical Engineering; 2014, 63, 1; 47-61
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Advanced control of direct-driven PMSG generator in wind turbine system
Autorzy:
Gajewski, P.
Pieńkowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/141159.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wind turbine
PMSG generator
MPPT control
pitch control
simulation studies
Opis:
The paper presents the advanced control system of the wind energy conversion with a variable speed wind turbine. The considered system consists of a wind turbine with the permanent magnet synchronous generator (PMSG), machine side converter (MSC), grid side converter (GSC) and control circuits. The mathematical models of a wind turbine system, the PMSG generator and converters have been described. The control algorithms of the converter systems based on the methods of vector control have been applied. In the advanced control system of the machine side converter the optimal MPPT control method has been used. Additionally the pitch control scheme is included in order to achieve the limitation of maximum power and to prevent mechanical damage of the wind turbine. In the control system of the grid side converter the control of active and reactive power has been applied with the application of Voltage Oriented Control (VOC). The performance of the considered wind energy system has been studied by digital simulation. The results of simulation studies confirmed the good effectiveness of the considered wind turbine system and very good performance of the proposed methods of vector control and control systems.
Źródło:
Archives of Electrical Engineering; 2016, 65, 4; 643-656
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of structure of heat recovery steam generator and of gas turbogenerator power repowering a 370 MW unit on the power plant operating in cogeneration cycle
Wpływ struktury kotła odzyskowego i mocy turbozespołu gazowego nadbudowujących blok 370 MW na jego pracę - praca skojarzona bloku
Autorzy:
Bartnik, R.
Buryn, Z.
Duczkowska-Kądziel, A.
Powiązania:
https://bibliotekanauki.pl/articles/173157.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kocioł odzyskowy
turbozespół gazowy
turbina parowa
heat recovery steam generator
gas turbogenerator
steam turbine
Opis:
W artykule zaprezentowano rezultaty termodynamicznych obliczeń doboru struktury kotła odzyskowego i mocy turbozespołu gazowego do bloku o mocy 370 MW zmodernizowanego do dwupaliwowego układu gazowo-parowego. Obliczenia przeprowadzono dla pracy skojarzonej bloku.
The paper presents results of technical calculations involving the selection of a structure of heat recovery steam generator and of gas turbogenerator power applied for adaptation of a coal-fired power unit with the rated capacity of 370 MW to dual-fuel steam-gas system. Calculations were conducted for a unit operating under cogeneration cycle.
Źródło:
Archiwum Energetyki; 2012, 42, 2; 197-210
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies