Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "traceability" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
An improved algorithm for the series step-up method based on a linear three-ports network
Autorzy:
Liu, Hao
Chen, Lixue
Wang, Xue
Yao, Teng
Gu, Xiong
Powiązania:
https://bibliotekanauki.pl/articles/2106422.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
voltage transformer
traceability method
calibration
high voltage
Opis:
Capacitive leakage and adjacent interference are the main influence sources of the measuring error in the traditional series step-up method. To solve the two problems, a new algorithm was proposed in this study based on a three-ports network. Considering the two influences, it has been proved that response of this three-ports network still has characteristics of linear superposition with this new algorithm. In this threeport network, the auxiliary series voltage transformers use a two-stage structure that can further decrease measurement uncertainty. The measurement uncertainty of this proposed method at 500/√3 kV is 6.8 ppm for ratio error and 7 μrad for phase displacement ( k = 2). This new method has also been verified by comparing its results with measurement results of the PTB in Germany over the same 110/√3 kV standard voltage transformer. According to test results, the error between the two methods was less than 2.7 ppm for ratio error and 2.9 μrad for phase displacement.
Źródło:
Metrology and Measurement Systems; 2022, 29, 2; 301--313
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Traceability of gas flow measurements in complex distribution systems - uncertainty approach vs error approach
Autorzy:
Džemić, Zijad
Širok, Brane
Drnovšek, Janko
Powiązania:
https://bibliotekanauki.pl/articles/220509.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
calibration
energy efficiency
error analyses
measurement uncertainty
traceability
Opis:
The objective of the paper is to analyse traceability issues in real-life gas flow measurements in complex distribution systems. The initial aim is to provide complete and traceable measurement results and calibration certificates of gas-flow meters, which correspond to specific installation conditions. Extensive work has been done to enable a more credible decision on how to deal in particular situations with the measurement uncertainty which is always subject of a flow meter’s calibration as a quantitative parameter value obtained in laboratory, and with the qualitative statement about the error of an outdoor meter. The laboratory simulation of a complex, real-life distributed system has been designed to achieve the initial aim. As an extension of standardized procedures that refer to the laboratory conditions, the proposed methods introduce additional “installation-specific” error sources. These sources could be either corrected (if identified) or considered as an additional “installation-specific” uncertainty contribution otherwise. The analysis and the results of the experimental work will contribute to more precise and accurate measurement results, thus assuring proper measurements with a known/estimated uncertainty for a specific gas flow installation. Also, the analysis will improve the existing normative documents by here presented findings, as well as fair trade in one of the most important and growing energy consumption areas regarding the legal metrology aspects. These facts will enable comparing the entire quantity of gas at the input of a complex distributed system with the cumulative sum of all individual gas meters in a specific installation.
Źródło:
Metrology and Measurement Systems; 2019, 26, 2; 419-429
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies