Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "stal austenityczna nierdzewna" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Influence of ageing on microstructure and mechanical properties of TP347HFG austenitic stainless steel
Autorzy:
Golański, Grzegorz
Purzyńska, Hanna
Powiązania:
https://bibliotekanauki.pl/articles/2204539.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
austenitic stainless steel
precipitates
microstructure
mechanical properties
mikrostruktura
właściwości mechaniczne
stal austenityczna nierdzewna
wytrącanie
Opis:
The paper presents the results of microstructural and mechanical investigation of long-term aged TP347HFG austenitic stainless steel. Ageing was performed at a time of up to 30 000 hours and the temperature of 600 and 650◦C. Ageing was proved to lead to the precipitation of secondary phase particles not only inside grains but also on the boundaries of grains and twins. The MX precipitates were observed inside the grains. However, M23C6 carbides and sigma phase precipitates were observed on grain boundaries. The changes in the microstructure of the examined steel translated into the mechanical properties, i.e. initially observed growth and then the decrease of yield strength and a gradual decrease in impact energy. The overageing process – a decrease in strength properties – was associated with the growth of the size of M23C6 carbides and the precipitation of the sigma phase. The reduction of impact energy in TP347HFG austenitic stainless steel was found to be associated with the precipitation of M23C6 carbides in the case of the 600◦C temperature, and the M23C6 carbides and sigma phase in the case of the 650◦C temperature. The rate of changes in the microstructure and mechanical properties depended on the ageing temperature.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2023, 71, 2; art. no. e144607
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of the laser treatment on microstructure of the surface layer of an X5CrNi18-10 austenitic stainless steel
Wpływ laserowego odkształcania na mikrostrukturę warstwy wierzchniej stali austenitycznej X5CrNi18-10
Autorzy:
Rozmus-Górnikowska, M.
Kusiński, J.
Blicharski, M.
Powiązania:
https://bibliotekanauki.pl/articles/351430.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
austenityczna stal nierdzewna
warstwa powierzchniowa
mikrostruktura
obróbka laserowa
LSP
SEM
TEM
austenitic stainless steel
surface layer
microstructure
laser shock processing (LSP)
Opis:
The influence of laser shock processing (LSP) on microstructure of the surface layer of an X5CrNi18-10 austenitic stainless steel was studied. The laser treatment was performed using a Q switched Nd:YAG ReNOVAL laser. It was found that the laser shock processing performed under the conditions of 230 MW/cm2 laser power density and pulse duration of 18 ns produced an ablation and melting of the thin surface layer of the treated material, what indicated that the process of LSP was not purely mechanical but rather thermo-mechanical one. However SEM images of the sample cross sections showed that clusters of slip bands were formed during the treatment in the near surface region. Transmission electron microscopy of the laser-shock treated steel have also revealed a very high density of dislocations and stacking faults. The changes in microstructure came down to 70 µm. It has been found that the laser shock processing induced plastic deformation of the surface layer of the investigated material.
Celem pracy była ocena wpływu laserowej obróbki odkształcającej na mikrostrukturę warstwy wierzchniej stali austenitycznej X5CrNi18-10. Proces laserowego odkształcania przeprowadzono za pomocą lasera impulsowego ReNOVALaser Nd:YAG z modulacją Q. W wyniku laserowego odkształcania stali impulsem lasera o gęstości mocy 230 MW/cm2 i czasie trwania impulsu 18 ns nastąpiło przetopienie cienkiej warstwy materiału, co wskazuje, że proces LSP nie był czysto mechaniczny, ale cieplno-plastyczny. Badania przeprowadzone za pomocą skaningowego i transmisyjnego mikroskopu elektronowego wykazały, że pod cienką warstwą przetopioną znajduje się materiał odkształcony. Na wytrawionych zgładach poprzecznych stali austenitycznej pod cienką warstwą przetopioną ujawniono obecność licznych pasm poślizgu. W mikrostrukturze warstwy wierzchniej stali austenitycznej po laserowej obróbce występowała duża gęstość dyslokacji oraz liczne błędy ułożenia. Badania wykazały, że zastosowane parametry procesu LSP, powodują odkształcenie plastyczne warstwy wierzchniej badanej stali austenitycznej.
Źródło:
Archives of Metallurgy and Materials; 2011, 56, 3; 717-721
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microstructural and Mechanical Characterization of Solidified Austenitic Stainless Steels
Autorzy:
Celik, A. G.
Polat, S.
Atapek, S. H.
Haidemenopoulos, G. N.
Powiązania:
https://bibliotekanauki.pl/articles/380707.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
theory of crystallization
Thermo-Calc
metallography
microstructure
tribology
stal nierdzewna
stal austenityczna
zestalenie
badanie mikrostrukturalne
badanie trybologiczne
oprogramowanie
Opis:
Among the family of stainless steels, cast austenitic stainless steels (CASSs) are preferably used due to their high mechanical properties and corrosion resistance. These steels owe their properties to their microstructural features consisting of an austenitic matrix and skeletal or lathy type δ-ferrite depending on the cooling rate. In this study, the solidification behavior of CASSs (304L and 316L grades) was studied using ThermoCalc software in order to determine the solidification sequence and final microstructure during cooling. Theoretical findings were supported by the microstructural examinations. For the mechanical characterization, not only hardness measurements but also tribological studies were carried out under dry sliding conditions and worn surfaces were examined by microscopy and 3D profilometric analysis. Results were discussed according to the type and amount of microstructural features.
Źródło:
Archives of Foundry Engineering; 2017, 17, 3; 163-167
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Physicochemical and electrochemical properties of AISI 316L stainless steel used for implants in human urinary system
Ocena własności fizykochemicznych i elektrochemicznych stali AISI 316L stosowanej na implanty w urologii
Autorzy:
Walke, W.
Przondziono, J.
Powiązania:
https://bibliotekanauki.pl/articles/351228.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
AISI 316L stainless steel
electrochemical impedance spectroscopy (EIS)
X-ray photoelectron spectroscopy (XPS)
scanning electron microscopy (SEM)
austenityczna stal nierdzewna AISI 316L
elektrochemiczna spektroskopia impedancyjna EIS
rentgenowska spektroskopia fotoelektronów XPS
skaningowa mikroskopia elektronowa (SEM)
Opis:
The main purpose of this study was to evaluate physicochemical and electrochemical properties of AISI 316L stainless steel with modified surface, used for implants in human urinary system. In order to simulate conditions, which occur in the tissue environment of the urinary system, the test pieces were exposed in a urinary solution at temperature of T=37 ±1ºC, for a period of 30 days. Evaluation of physicochemical properties of biomaterial was made on the basis of surface chemical analysis (XPS). To evaluate the effects which occur on the surface of the examined steel, Electrochemical Impedance Spectroscopy (EIS) method was also employed. Analysis of test results shows favourable influence of the suggested surface treatment of AISI 316L stainless steel. Samples having electrolytically polished and chemically passivated surface featured the best physicochemical and electrochemical characteristics.
Podstawowym kryterium przydatności biomateriału metalowego na implanty urologiczne (stenty urologiczne) jest biokompatybilność. Jest ona w głównej mierze związana z własnościami fizykochemicznymi powierzchni implantu, które powinny być dostosowane do cech środowiska tkanek układu moczowego człowieka. W celu poprawy biokompatybilności stali Cr-Ni-Mo ustalono warunki wytwarzania warstw pasywnych na jej powierzchni. Wytworzenie warstwy pasywnej obejmowało etap polerowania elektrolitycznego i pasywowania. Taki sposób obróbki powierzchniowej zapewnił chropowatość Ra < 0,16 μm wymaganą dla tego rodzaju implantów. W pracy tej szczególną uwagę skoncentrowano na analizie długotrwałego oddziaływania środowiska sztucznego moczu na własności fizykochemiczne wytypowanej stali. Zasadniczym celem pracy była ocena własnosci fizykochemicznych i elektrochemicznych stali AISI 316L o modyfikowanej powierzchni stosowanej na implanty w układzie moczowym człowieka. W celu zasymulowania warunków występujących w środowisku tkankowym układu moczowego próbki poddawano ekspozycji w roztworze sztucznego moczu o temperaturze T=37±1ºC przez okres 30 dni. O przydatności zaproponowanej warstwy pasywnej do uszlachetniania powierzchni stali w znacznym stopniu decyduje jej skład chemiczny. Dlatego w pracy wykonano badania składu chemicznego metodą spektroskopii fotoelektronów (XPS), z użyciem wielofunkcyjnego spektrometru elektronów PHI 5700/660 firmy Physical Electronics, podczas których zidentyfikowano i wyznaczono stężenia atomowe pierwiastków w badanych warstwach pasywnych. Dla próbek przeprowadzono pomiar widma fotoelektronów w szerokim zakresie energii wiązania od 0÷1400 eV oraz dokładne pomiary linii widmowych poszczególnych pierwiastków składowych z warstwy powierzchniowej. Dla oceny zjawisk zachodzacych na powierzchni badanej stali zastosowano również metodę elektrochemicznej spektroskopii impedancyjnej (EIS). Pomiary przeprowadzono z wykorzystaniem systemu pomiarowego AutoLab PGSTAT 302N wyposażonego w moduł FRA2 (Frequency Response Analyser). Badania przeprowadzono w alternatywnym roztworze symulującym środowisko moczu człowieka. Zastosowana w pracy mikroskopia skaningowa pozwoliła na ocene stanu powierzchni stali AISI 316L przed i po ekspozycji w sztucznym moczu. Analiza wyników badań wskazuje na korzystny wpływ zaproponowanej obróbki powierzchniowej stali AISI 316L. Najkorzystniejszą charakterystykę fizykochemiczną i elektrochemiczną miały próbki o powierzchni polerowanej elektrolitycznie i pasywowanej chemicznie. Przeprowadzone w pracy badania stanowią podstawę do dalszych analiz związanych z zagadnieniem biokompatybilności stali Cr-Ni-Mo stosowanej na implanty w urologii.
Źródło:
Archives of Metallurgy and Materials; 2013, 58, 2; 625-630
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies