Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "removal nitrogen" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
DNA vs RNA based studies of nitrogen removal bacteria genes via qPCR
DNA i RNA-zależna analiza genów bakterii przemian azotowych metodą qPCR
Autorzy:
Banach-Wiśniewska, Anna
Gamoń, Filip
Ziembińska-Buczyńska, Aleksandra
Powiązania:
https://bibliotekanauki.pl/articles/1845429.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
qPCR
RT-qPCR
nitrogen removal bacteria
relative gene abundance
bakterie usuwające azot
względna obfitość genów
Opis:
Improvements in water quality requires the removal of nitrogen compounds from wastewater. The most promising and cost-effective methods for this purpose are biological ones based on activated sludge microorganisms such as nitrifiers, denitrifiers, and anammox bacteria. Due to the most of the nitrogen removal bacteria are uncultivable in a laboratory, the application of the molecular tools is required to investigate microorganisms involved in the nitrogen removal. In case of this study for the analysis of relative genes abundance of nitrogen removal bacteria, quantitative PCR (qPCR) based on bacterial DNA and qPCR preceded by reverse transcription (RT-qPCR) based on bacterial mRNA as a template, were used with specific bacterial functional genes (amoA, nrxA, nirS, nirK, hzo). Samples from four anammox sequencing batch reactors (SBRs) were analyzed, while the nitrogen removal process and bacteria growth were supported by biomass immobilization and nanoparticles addition. There were statistically significant differences between results obtained in the case of mRNA and DNA (p<0.05). Statistically significant positive correlations were found between results obtained with those two approaches. In case of mRNA analysis, positive results were obtained only for hzo, amoA and partly for nirS genes, despite additional purification and removal of inhibitors from samples prior to reaction.
Z uwagi na to, że większości bakterii przemian związków azotowych nie można wyizolować w postaci czystych kultur, do ich zbadania konieczne jest zastosowanie metod biologii molekularnej. Jedną z najczęściej stosowanych w tym celu jest ilościowa reakcja łańcuchowa polimerazy (ang. Quantitative Polimerase Chain Reaction, qPCR). Celem eksperymentu było porównanie wyników analizy wybranych genów funkcyjnych bakterii przemian związków azotowych przy pomocy metody qPCR wykonanej na matrycy DNA i RNA (po odwrotnej transkrypcji). Względna liczebności genów funkcyjnych analizowana była z zastosowaniem metody qPCR (na matrycy DNA) oraz RT-qPCR (ang. Reverse Transcription-qPCR) (na matrycy RNA). Analizę przeprowadzono w oparciu o geny: amoA, nrxA, nirS, nirK i hzo. Próbki osadu czynnego pobrano z czterech sekwencyjnych reaktorów porcjowych, w których proces usuwania azotu i wzrostu bakterii wspomagano za pomocą immobilizacji biomasy i dodatkiem nanocząstek. Wykazano statystycznie istotne różnice między wynikami uzyskanymi w przypadku badań mRNA i badań opartych na DNA (p<0,05). Wyniki uzyskane za pomocą zastosowanych narzędzi biologii molekularnej (qPCR, RT-qPCR) były skorelowane pozytywnie. W przypadku analizy opartej na mRNA pozytywne wyniki uzyskano tylko dla genów hzo, amoA i częściowo dla genów nirS, pomimo dodatkowego oczyszczania i usuwania inhibitorów z próbek przed reakcją. Należy podkreślić, że w zależności od matrycy zastosowanej w qPCR (bakteryjne DNA lub cDNA zsyntetyzowane z bakteryjnego mRNA w procesie odwrotnej transkrypcji) uzyskane wyniki mogą wskazywać na różne informacje naukowe. Pomimo znaczących różnic pomiędzy wynikami otrzymanymi za pomocą dwóch metod, obliczone współczynniki korelacji Spearmana wskazują na wzajemne powiązanie pomiędzy otrzymanymi wynikami oraz powiązania ekologiczne pomiędzy bakteryjnymi genami przemian związków azotowych.
Źródło:
Archives of Environmental Protection; 2021, 47, 1; 19-25
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Start-up, modelling and simulation of the anammox process in a membrane bioreactor
Autorzy:
Cema, G.
Sochacki, A.
Kubiatowicz, J.
Gutwiński, P.
Surmacz-Górska, J.
Powiązania:
https://bibliotekanauki.pl/articles/185149.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
activate sludge model
anammox
computer simulation
modeling
nitrogen removal
aktywowane modelu osadu
symulacja komputerowa
modelowanie
usuwanie azotu
Opis:
There are certain well-known methods of diminishing concentrations of nitrogen compounds, but they are ineffective in case of nitrogen-rich wastewater with a low content of biodegradable carbon. Partial nitritation followed by anaerobic ammonium oxidation (Anammox) process appear to be an excellent alternative for traditional nitrification and denitrification. This paper presents the feasibility of successful start-up of Anammox process in a laboratory-scale membrane bioreactor (MBR). It was shown that the combination of membrane technology and Anammox process allowed to create a new highly efficient and compact system for nitrogen removal. It was possible to achieve average nitrogen removal efficiency equal to 76.7 +/-8.3%. It was shown that the start-up period of 6 months was needed to obtain high nitrogen removal efficiency. The applied biochemical model of the Anammox process was based on the state-of-the-art Activated Sludge Model No.1 (ASM 1) which was modified for accounting activity of autotrophs (nitrite-oxidising bacteria and nitrateoxidising bacteria) and anammox bacteria. In order to increase the predictive power of the simulation selected parameters of the model were adjusted during model calibration. Readjustment of the model parameters based on the critically evaluated data of the reactor resulted in a satisfactory match between the model predictions and the actual observations.
Źródło:
Chemical and Process Engineering; 2012, 33, 4; 639-650
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of electric current density on specific denitrification rate of and nitrogen removal rate in electrochemical and electrobiological rotating contactor
Wpływ gęstości prądu elektrycznego na właściwą szybkość denitryfikacji i na szybkość usuwania azotu w elektrochemicznym i elektrobiologicznym złożu obrotowym
Autorzy:
Rodziewicz, Joanna
Janczukowicz, Wojciech
Mielcarek, Artur
Bryszewski, Kamil
Powiązania:
https://bibliotekanauki.pl/articles/1845362.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electric current density
rotating electrochemical disk contactor
rotating electrobiological disk contactor
specific denitrification rate
nitrogen removal rate
gęstość prądu elektrycznego
obrotowy elektrochemiczny stycznik dyskowy
obrotowy elektrobiologiczny stycznik dyskowy
określony stopień denitryfikacji
szybkość usuwania azotu
Opis:
This study aimed to determine the influence of the electric current density on the rate of nitrogen compounds removal (rN) and the specific rate of denitrification (rD) in a rotating electrochemical disk contractor (RECDC) and a rotating electro-biological disk contactor (REBDC). In REBDC and RECDC, the cathode consisted of disks with immobilized biomass and disk, from which biofilm was periodically removed, respectively. An aluminum anode was mounted in contactor chambers. The study was conducted using synthetic wastewater with characteristics similar to wastewater from soilless cultivation of tomatoes. The first stage of the study determined rN and rD in the RECDC. The second stage determined rN and rD in the REBDC. Four hydraulic retention times (HRT) were tested: 4 h, 8 h, 12 h, and 24 h, with electric current densities of 0.63 A/m2, 1.25 A/m2, 2.50 A/m2, 5.00 A/m2, and 10.00 A/m2. In RECDC, a linear dependency was observed between rN and current density in the examined HRTs, whereas in REBDC, a logarithmic dependency was confirmed between rN and current density. In both contactors, an exponential dependency was observed between rD and current density. The specific rate of denitrification decreased when the current density and HRT were increased. The study showed that, in both contactors, the rate of total nitrogen removal increased when the current density was increased and the HRT was decreased.
Celem pracy było określenie wpływu gęstości prądu na szybkość usuwania związków azotu (rN) i na specyficzną szybkość procesu denitryfikacji (rD) w elektrochemicznym tarczowym złożu obrotowym (RECDC) i elektrobiologicznym tarczowym złożu obrotowym (REBDC). W elektrochemicznym tarczowym złożu obrotowym (RECDC) i elektrobiologicznym tarczowym złożu obrotowym (REBDC) katodę stanowiły odpowiednio tarcze pokryte błoną biologiczną i tarcze z których okresowo usuwano błonę biologiczną. Aluminowa anoda była umieszczona w zbiornikach złoża. Badania przeprowadzono na ściekach o wskaźnikach fizykochemicznych podobnych do ścieków z bezglebowej uprawy pomidorów. W pierwszym etapie badań określono wartości rN and rD w RECDC podczas gdy w drugim w REBDC. Zastosowano cztery wartości hydraulicznego czasu zatrzymania (HRT): 4 h, 8 h, 12 h and 24 h dla następujących gęstości prądu: 0.63 A/m2, 1.25 A/m2, 2.50 A/m2, 5.00 A/m2 and 10.00 A/m2. W elektrochemicznym złożu zaobserwowano liniową zależność pomiędzy rN i gęstością prądu, podczas gdy w złożu elektrobiologicznym zależność logarytmiczną. Dla obu złóż stwierdzono wykładniczą zależność pomiędzy rD i gęstością prądu. Specyficzną szybkość procesu denitryfikacji malała wraz ze wzrostem gęstości prądu i HRT. Badania pokazały, że w obu złożach, elektrochemicznym i elektrobiologicznym szybkość usuwania związków azotu obniżała się wraz ze wzrostem gęstości prądu i obniżaniem HRT.
Źródło:
Archives of Environmental Protection; 2020, 46, 4; 23-32
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies