Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "reliability of networks" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Analysis of sectionalizing switch placement in medium voltage distribution networks in the aspect of improving the continuity of power supply
Autorzy:
Bąchorek, W.
Benesz, M.
Powiązania:
https://bibliotekanauki.pl/articles/201362.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
reliability of distribution networks
sectionalizing switches
SAIDI
Opis:
The paper addresses the problem of placement of sectionalizing switches in medium voltage distribution networks. Proper placement of sectionalizing switches is one of the elements leading to higher power networks reliability. The methods of optimal allocation of such switches in a MV distribution network are presented in the paper. SAIDI was used as a criterion for the sectionalizing switches placement. For selecting optimum placements, three methods were used: brute force method, evolutionary algorithm and heuristic algorithm. The calculations were performed for a real MV network.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 3; 459-466
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reliability improvement of power distribution line exposed to extreme icing in Poland
Autorzy:
Ciesielka, W.
Gołaś, A.
Szopa, K.
Bąchorek, W.
Benesz, M.
Kot, A.
Moskwa, S.
Zydroń, P.
Powiązania:
https://bibliotekanauki.pl/articles/200660.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power distribution networks
overhead lines
finite element method
reliability
icing
rime
prevention of line icing
Opis:
Currently, overhead lines dominate in the Polish medium and low voltage distribution networks. Maintaining their high reliability constitutes a very important challenge, especially under the severely changing climate conditions. An overhead power line exposed to high ice and rime loads has been considered. Using the finite element method (FEM), mechanical reliability of the distribution infrastructure was examined under various atmospheric conditions. Loads under the stressful conditions of rime, ice and wind were determined for the weakest section of the 30 kV overhead line, which consisted of concrete poles and ACSR conductors. SAIDI and SAIFI reliability indices and costs were determined for several variants of object reconstruction. The results allowed for determination of a solution relying on relocating the cables of all lateral branches and main line ice protection, through a system based on a weather-coordinated increase of the electrical load. To verify the solution proposed, a field experiment was conducted. The experiment confirmed the effectiveness of the solution proposed that appears to be universal. The paper is a result of synergic cooperation of two academic teams, i.e. a mechanical and electrical power engineering one, and the Distribution System Operator (DSO).
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 5; 1113-1125
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Main aspects influencing the evaluation of atmospheric overvoltages in high-voltage networks
Autorzy:
Borecki, Michał
Ciuba, Maciej
Kharchenko, Yevhen
Khanas, Yuriy
Powiązania:
https://bibliotekanauki.pl/articles/2173536.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
overvoltage protection
high voltage networks
reliability of power grids
risk analysis
ochrona przed wysokim napięciem
sieć wysokiego napięcia
niezawodność sieci elektroenergetycznych
ocena ryzyka
Opis:
The effectiveness of lightning protection on the power and distribution grid is a significant factor, which influences the power distribution reliability and the failure rate of system elements. As part of this article, a mathematical model will be presented, taking into account selected parameters that affect the assessment of the lightning hazard of an overhead line. The proposed model will consider the location of the object near the line and the adjustment of line conductor overhangs. Moreover, the mentioned mathematical model allows for analyzing the impact of considered parameters on the protection level of the power system, and transient overvoltages that occur in this system. The article contains also a detailed description of an effective and fast method to assess the lightning discharge impact on the power system with insufficient data. The introduced model was tested to verify the correctness of its operation by comparison of calculation results and functional data. High convergence of calculated and functional data and uncomplicated model structure ensure a wide range of applications for the proposed solution to easily prevent emergency situations in the power system. Furthermore, the described model gives the opportunity to assess the reduction of the range of selectivity zone associated with the power line, in conjunction with the impact of constructional peculiarities and a near object.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 1; art. no. e135838
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Main aspects influencing the evaluation of atmospheric overvoltages in high-voltage networks
Autorzy:
Borecki, Michał
Ciuba, Maciej
Kharchenko, Yevhen
Khanas, Yuriy
Powiązania:
https://bibliotekanauki.pl/articles/2090728.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
overvoltage protection
high voltage networks
reliability of power grids
risk analysis
ochrona przed wysokim napięciem
sieć wysokiego napięcia
niezawodność sieci elektroenergetycznych
ocena ryzyka
Opis:
The effectiveness of lightning protection on the power and distribution grid is a significant factor, which influences the power distribution reliability and the failure rate of system elements. As part of this article, a mathematical model will be presented, taking into account selected parameters that affect the assessment of the lightning hazard of an overhead line. The proposed model will consider the location of the object near the line and the adjustment of line conductor overhangs. Moreover, the mentioned mathematical model allows for analyzing the impact of considered parameters on the protection level of the power system, and transient overvoltages that occur in this system. The article contains also a detailed description of an effective and fast method to assess the lightning discharge impact on the power system with insufficient data. The introduced model was tested to verify the correctness of its operation by comparison of calculation results and functional data. High convergence of calculated and functional data and uncomplicated model structure ensure a wide range of applications for the proposed solution to easily prevent emergency situations in the power system. Furthermore, the described model gives the opportunity to assess the reduction of the range of selectivity zone associated with the power line, in conjunction with the impact of constructional peculiarities and a near object.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 1; e135838, 1--8
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies