Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "pomiar" wg kryterium: Temat


Tytuł:
Influence of time delays of robotic total stations with high sampling frequency on accuracy of measurements to moving prisms
Wpływ opóźnień czasowych tachimetrów zrobotyzowanych o dużej częstotliwości rejestracji na dokładność pomiarów do ruchomych pryzmatów
Autorzy:
Lenda, G.
Uznański, A.
Strach, M.
Powiązania:
https://bibliotekanauki.pl/articles/231163.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pomiar w ruchu
pomiar pozycji
pomiar kinematyczny
technika pomiarowa
tachimetr zrobotyzowany
measurement
mobile target
position measurement
kinematic measurement
measurement technique
robotic total stations
Opis:
Robotic total stations are a group of surveying instruments that can be used to measure moving prisms. These devices can generate significant errors during kinematic surveys. This is due to the different speeds of the total station’s measurement subsystems, which results in the observations of the point location being performed in different places of the space. Total stations which are several years old may generate errors of up to a few dozen centimeters. More modern designs, with much lower delays of the mechanical and electronic subsystems, theoretically allow to significantly reduce the values of the errors. This study involved the performance of kinematic tests on the modern robotic total station Leica MS50 in order to determine the values of measurement errors, and also to define the possibility of using them for the above-mentioned applications.
W opracowaniu przeprowadzono kinematyczne testy współczesnego tachimetru zrobotyzowanego Leica MS50 pod kątem oceny wartości błędów pomiarowych, a tym samym możliwości użycia do wyżej wymienionych zastosowań. Określanie pozycji ruchomego pryzmatu odbywa się w analogiczny sposób jak celów nieruchomych, poprzez pomiar odległości oraz kąta pionowego i poziomego. Te trzy wielkości, ze względów technicznych, nie mogą być jednak rejestrowane dokładnie w tym samym czasie. Dla pomiarów statycznych nie ma to znaczenia, ponieważ punkt pozostaje w spoczynku. Podczas pomiarów zrobotyzowanych, w trakcie ciągłego ruchu pryzmatu, wzajemne opóźnienia czasowe rejestracji długości i kątów mogą negatywnie wpływać na dokładność, ponieważ na pozycję punktu składają się obserwacje wykonane w różnych miejscach przestrzeni. Aby wyznaczyć wartości tak powstałych błędów, przeprowadzono badania na prostoliniowym torze w laboratorium metrologicznym AGH w Krakowie. Do analiz przyjęto, że oś toru, po którym poruszał się obserwowany pryzmat pokrywa się z osią Y prostokątnego układu współrzędnych. Poprzeczne odchyłki od tego toru w płaszczyźnie poziomej wynikają z opóźnień kątów poziomych względem długości (odchyłki mx), w pionowej, z opóźnień kątów pionowych (odchyłki mz). Tor testowy do pomiarów stanowiła baza komparacyjna dalmierzy tachimetrów elektronicznych, której odchyłki od linii prostej zostały skatalogowane na podstawie pomiarów wykonanych tachimetrem precyzyjnym TC2002. Kształt toru został następnie opisany za pomocą interpolacyjnej funkcji sklejanej, uwzględniającej jego lokalne nierówności, dając model toru. Odchyłki wynikające z analizowanych opóźnień czasowych od tak określonego toru, wyznaczono jako różnicę rzędnych punktu - wyznaczonej i modelowej dla tej samej wartości odciętych. Po torze tym poruszał się ze stałą prędkością wózek napędzany silnikiem krokowym. Badania przeprowadzono dla prędkości 1 m/s (przeciętna prędkość piechura) i 3 m/s.
Źródło:
Archives of Civil Engineering; 2019, 65, 1; 31-48
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Orientacja pozytywna i jej pomiar: polska adaptacja skali orientacji pozytywnej
Autorzy:
Łaguna, Mariola
Oleś, Piotr
Filipiuk, Dorota
Powiązania:
https://bibliotekanauki.pl/articles/951724.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pozytywna orientacja
samoocena
optymizm
satysfakcja z życia
pomiar psychologiczny
Opis:
Pozytywna orientacja jest to podstawowa tendencja do zauważania i przywiązywania wagi do pozytywnych aspektów życia, doświadczeń i samego siebie (Caprara, 2009). Stanowi ona zmienną latentną wyższego rzędu łączącą w sobie trzy komponenty: samoocenę, optymizm i satysfakcję z życia. Dotychczas badana była za pomocą trzech skal mierzących osobno każdy z tych komponentów. Artykuł prezentuje polską wersję nowej krótkiej Skali Orientacji Pozytywnej, która znacznie skraca i upraszcza badanie. Właściwości psychometryczne skali zostały opracowane na próbie 905 osób. Metoda posiada jednoczynnikową strukturę, wykazuje wystarczającą spójność wewnętrzną (α = 0,77-0,84), stałość (rtt=0,84) oraz potwierdzoną trafność zbieżną.
Źródło:
Studia Psychologiczne (Psychological Studies); 2011, 49, 4; 47-54
0081-685X
Pojawia się w:
Studia Psychologiczne (Psychological Studies)
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanika kwantowa a problem obiektywności
Quantum Mechanics and Objectivity Problem
Autorzy:
Łukasik, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/577744.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
mechanika kwantowa
obiektywność
pomiar
quantum mechanics
objectivity
measurement
Opis:
W artykule argumentuję, że odróżnienie epistemologicznego i ontologicznego pojęcia obiektywności, oraz radykalnej obiektywności ontologicznej od obiektywności ontologicznej zrelatywizowanej do przyrządu pomiarowego pozwala na adekwatną analizę sytuacji poznawczej w mechanice kwantowej i przeciwstawienie się subiektywistycznym interpretacjom mechaniki kwantowej.
In the article I argue that distinction between the epistemological notion and objectivity from ontological notion of objectivity, as well as radical ontological objectivity and ontological objectivity relative to the measuring instrument allows us for an adequate analysis of the cognitive situation in quantum mechanics and undermines the subjectivist interpretations of it.
Źródło:
Zagadnienia Naukoznawstwa; 2015, 51, 2(204); 137-146
0044-1619
Pojawia się w:
Zagadnienia Naukoznawstwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Konstruowanie typologii i klasyfi kacji wielowymiarowych dla potrzeb diagnostyki medycznej
Constructing Multidimensional Typologies and Classifi cations for Medical Diagnosis
Autorzy:
Rzepiński, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/577486.pdf
Data publikacji:
2016-04
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pomiar
klasyfikacja
typologia wielowymiarowa
diagnoza
measurement
classification
multidimensional typology
diagnosis
Opis:
Procedura typologii charakteryzowana jest w literaturze z zakresu metodologii w bardzo różny sposób. Zasadnicze różnice dotyczą warunków formalnych, jakie powinna spełniać typologia oraz związków tej procedury z klasyfi kacją wielowymiarową. Ustalenia dokonane w niniejszym artykule pozwalają omówić funkcje, jakie procedury typologii i klasyfi kacji wielowymiarowej pełnią w diagnostyce medycznej. Dokonane rozstrzygnięcia zilustrowane są przykładami typologii dwuwymiarowej stosowanej w diagnostyce nadciśnienia tętniczego oraz klasyfi kacji wielowymiarowej Forrestera przeprowadzonej w zakresie kardiologii inwazyjnej. Omówione przykłady pozwalają ukazać funkcję prognostyczną obu tych procedur oraz ich znaczenie dla procesu podejmowania decyzji medycznych.
The typology process is described in the methodology literature using various methods. The core differences consist in the formal conditions which the typology is required to meet and the process’s relations with multi-dimensional classifi cation. With the fi ndings established in this article, it is possible to describe the functions which typology and multi-dimensional classifi cation processes perform in medical diagnostics. The conclusions reached in this article have been illustrated with examples of the multi-dimensional typology which is applied in arterial hypertension diagnostics and Forrester’s multi-dimensional classifi cation for invasive cardiology. The examples discussed demonstrate the prognostic function of both procedures and their signifi cance for medical decision making.
Źródło:
Zagadnienia Naukoznawstwa; 2016, 52, 2(208); 199-218
0044-1619
Pojawia się w:
Zagadnienia Naukoznawstwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermovision determination of the furnace chamber environment temperature using the technical black-body model
Autorzy:
Musiał, D.
Wyczółkowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/239977.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ciało czarne
pomiar temperatury
termowizja
black body
temperature measurements
thermovision
Opis:
The article describes the methodology for the determination of ambient temperature for thermovision measurements. The adopted methodology consists in the use of the technical blackbody model. Determining the value of the ambient temperature parameter makes it possible to enhance the accuracy of temperature measurement of objects exposed to strong irradiation using a thermovision camera.
Źródło:
Archives of Thermodynamics; 2010, 31, 4; 25-35
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calibration and verification of an original module measuring turbojet engine blades geometric parameters
Autorzy:
Szybicki, Dariusz
Burghardt, Andrzej
Kurc, Krzysztof
Pietruś, Paulina
Powiązania:
https://bibliotekanauki.pl/articles/139580.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
industrial robot
blade measurement
robotic machining
robot przemysłowy
pomiar łopatki
obróbka zrobotyzowana
Opis:
The article presents the issue of calibration and verification of an original module, which is a part of the robotic turbojet engines elements processing station. The task of the module is to measure turbojet engine compressor blades geometric parameters. These type of devices are used in the automotive and the machine industry, but here we present their application in the aviation industry. The article presents the idea of the module, operation algorithm and communication structure with elements of a robot station. The module uses Keyence GT2-A32 contact sensors. The presented information has an application nature. Functioning of the module and the developed algorithm has been tested, the obtained results are satisfactory and ensure sufficient process accuracy. Other station elements include a robot with force control, elements connected to grinding such as electrospindles, and security systems.
Źródło:
Archive of Mechanical Engineering; 2019, LXVI, 1; 97-109
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of the electrical conductivity and humidity sensitivity characteristics of BaTiO3 ceramics with PMMA additive
Badanie przewodności elektrycznej i charakterystyka czułości na wilgotność ceramiki BaTiO3 z dodatkiem PMMA
Autorzy:
Ertug, B.
Boyraz, T.
Addemir, O.
Powiązania:
https://bibliotekanauki.pl/articles/355088.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pomiar wilgotności
czujnik protonic
PMMA
barium titanate
microstructure
electrical conductivity
humidity sensitivity
Opis:
Humidity sensing is a requirement for human comfort and several industrial processes. There are two main types of humidity-sensing mechanisms. One of them is the protonic sensor which utilizes ionic conductivity due to water physisorption or capillary condensation in micropores. The semiconductor sensors use the changes in electronic conductivity due to water chemisorption. In this study, an ionic type of sensor was fabricated. Barium titanate based ceramic humidity sensors made with PMMA(Polymethyl metacrylate) as the PFA (Pore-forming agent) were investigated. All compositions included 0.18 wt. % of La2O3 and three different PMMA contents. The green compacts were heated at 1200-1500 º C for 2-6 h. in air and then furnace cooled. The fundamental characteristics of ceramic humidity sensors, electrical conductivity and humidity sensitivity were determined and discussed in relation to microstructural features, porosity, phase analysis and grain size data. The experimental results of conductivity measurements were evaluated in terms of practical sensor applications.
Pomiar wilgotności jest istotny dla ludzkiej wygody i wielu procesów przemysłowych. Istnieją dwa główne typy mechanizmów wykrywania wilgoci. Jednym z nich jest czujnik protonic, który wykorzystuje przewodnictwo jonowe dzięki fizyko sorpcji wody lub kondensacji kapilarnej w mikroporach. Czujniki półprzewodnikowe wykorzystują zmiany przewodnictwa elektrycznego ze względu na chemisorpcje wody. W ramach niniejszej pracy, zbudowany został czujnik jonowy. Badane były ceramiczne czujniki wilgotności oparte o tytanian baru z dodatkiem PMMA (polimetakrylan metakrylanu) jako czynnika tworzenia porów. Wszystkie badane składy zawierały 0,18%.wag La2O3 i trzy różne zawartości PMMA. Zielone pakiety ogrzewano w temperaturze 1200-1500 º C przez 2-6 godzin w powietrzu, a następnie studzono razem z piecem. Podstawowe cechy ceramicznych czujników wilgotności, przewodność elektryczną i wrażliwość na wilgotność zostały określone i omówione w odniesieniu do cech mikrostruktury, porowatości, analizy fazowej i danych o wielkości ziarna. Eksperymentalne wyniki pomiarów przewodności były oceniane w kategoriach praktycznych zastosowań czujników.
Źródło:
Archives of Metallurgy and Materials; 2012, 57, 2; 437-442
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of transient fluid temperature using the inverse method
Autorzy:
Jaremkiewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/240590.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
temperature measurement
transient conditions
uncertainty analysis
pomiar temperatury
warunki przejściowe
analiza niepewności
Opis:
This paper proposes an inverse method to obtain accurate measurements of the transient temperature of fluid. A method for unit step and linear rise of temperature is presented. For this purpose, the thermometer housing is modelled as a full cylindrical element (with no inner hole), divided into four control volumes. Using the control volume method, the heat balance equations can be written for each of the nodes for each of the control volumes. Thus, for a known temperature in the middle of the cylindrical element, the distribution of temperature in three nodes and heat flux at the outer surface were obtained. For a known value of the heat transfer coefficient the temperature of the fluid can be calculated using the boundary condition. Additionally, results of experimental research are presented. The research was carried out during the start-up of an experimental installation, which comprises: a steam generator unit, an installation for boiler feed water treatment, a tray-type deaerator, a blow down flashvessel for heat recovery, a steam pressure reduction station, a boiler control system and a steam header made of martensitic high alloy P91 steel. Based on temperature measurements made in the steam header using the inverse method, accurate measurements of the transient temperature of the steam were obtained. The results of the calculations are compared with the real temperature of the steam, which can be determined for a known pressure and enthalpy.
Źródło:
Archives of Thermodynamics; 2014, 35, 1; 61-76
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The accuracy assessment of determining the axis of railway track basing on the satellite surveying
Ocena dokładności określania osi toru kolejowego na drodze pomiarów satelitarnych
Autorzy:
Koc, W.
Specht, C.
Chrostowski, P.
Palikowska, K.
Powiązania:
https://bibliotekanauki.pl/articles/224154.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
trasa kolejowa
pomiar przebiegu trasy
pomiary satelitarne
NAVGEO
sieć geodezyjna ASG-EUPOS
Opis:
In 2009, at the Gdansk University of Technology there have been carried out, for the first time, continuous satellite surveying of railway track by the use of the relative phase method based on geodesic active network ASG-EUPOS and NAVGEO service. Still continuing research works focused on the GNSS multi-receivers platform evaluation for projecting and stock-taking. In order to assess the accuracy of the railway track axis position, the values of deviations of transverse position XTE (Cross Track Error) were evaluated. In order to eliminate the influence of random measurement errors and to obtain the coordinates representing the actual shape of the track, the XTE variable was analyzed by signal analysis methods (Chebyshev low-pass filtering and fast Fourier transform). At the end the paper presents the module of the computer software SATTRACK which currently has been developing at the Gdansk University of Technology. The program serves visualization, assessment and design process of railway track, adapted to the technique of continuous satellite surveying. The module called TRACK STRAIGHT is designed to assess the straight sections. A description of its operation as well as examples of its functions has been presented.
W 2009 roku na Politechnice Gdańskiej rozpoczęto badania nad wykorzystaniem serwisu pomiarów fazowych NA VGEO aktywnej sieci geodezyjnej ASG-EUPOS dla przeprowadzania ciągłych pomiarów przebiegu trasy kolejowej. Celem kontynuowanych badań jest próba oceny możliwości zastosowania pomiarów fazowych GNSS, realizowanych przez kilka odbiorników, dla projektowania oraz inwentaryzacji toru kolejowego. Do oceny dokładności określenia osi toru wyznaczono wartości odchyleń poprzecznych pozycji (ang.: XTE - cross track error) od kierunku zasadniczego. Zmienną XTE poddano metodom analizy sygnałów (filtracji dolnoprzepustowej Czebyszewa i szybkiej transformacji Fouriera) w celu wyeliminowania wpływu przypadkowych błędów pomiarowych i uzyskania współrzędnych reprezentujących rzeczywisty kształt toru. Na końcu pracy przedstawiono moduł opracowywanego w Politechnice Gdańskiej programu komputerowego SATTRACK do wizualizacji, oceny i projektowania trasy kolejowej, dostosowanego do techniki ciągłych pomiarów satelitarnych. Jest to moduł TRACK_STRAIGHT, służący do oceny odcinków prostych. Pokazano opis jego funkcjonowania oraz przykłady zastosowania odpowiednich funkcji.
Źródło:
Archives of Transport; 2012, 24, 3; 307-320
0866-9546
2300-8830
Pojawia się w:
Archives of Transport
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Vehicles in motion parameters measurement pre-selection system
System preselekcyjnego pomiaru parametrów pojazdów samochodowych w ruchu
Autorzy:
Mitas, A. W.
Konior, W.
Powiązania:
https://bibliotekanauki.pl/articles/224253.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
samochody ciężarowe
ważenie preselekcyjne samochodów
pomiar preselekcyjny
pre-selection measurement
heavy vehicles
Opis:
Heavy goods vehicles moving on public roads are driven by people belonging to all walks of society, including those, who for the price paid by others are ready to multiply their own profits. This problem is discussed in the article, in particular in terms of overloading car's. There is pointed out on the technical implications of such actions. Later in the paper are presented the basic assumptions of lorries pre-selection weighting, which could be treated as a potential reason to the implementation of time-consuming exact weighting procedure. The discussion of hardware-software solution of pre-selection weighing systems was related to practical applications in national conditions. The article highlighted the problem of dynamic effects, significantly influencing the process of weighting in motion.
Pojazdy ciężarowe poruszające się po drogach publicznych kierowane są przez ludzi należących do pełnego przekroju społecznego, w tym także takich, którzy za cenę płaconą przez innych są gotowi do pomnażania własnych zysków. Problem ten poruszono w artykule, w szczególności w aspekcie przeciążenia samochodu. Wskazano na skutki techniczne takiego działania. W dalszej części opracowania przedstawiono podstawowe założenia preselekcyjnego ważenia samochodów ciężarowych, stanowiącego przyczynek do wykonania czasochłonnej procedury ważenia dokładnego. Dyskusję rozwiązania sprzętowo-programowego systemów ważenia preselekcyjnego odniesiono do praktycznych aplikacji w warunkach krajowych. W artykule zwrócono uwagę na problematykę dynamicznych efektów, istotnie wpływających na proces ważenia w czasie ruchu pojazdu.
Źródło:
Archives of Transport; 2012, 24, 1; 43-61
0866-9546
2300-8830
Pojawia się w:
Archives of Transport
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of exhaust gas temperature distribution within a furnace of a stoker fired boiler as a function of its operating parameters
Autorzy:
Krawczyk, P.
Badyda, K.
Szczygieł, J.
Młynarz, S.
Powiązania:
https://bibliotekanauki.pl/articles/240827.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
exhaust gas temperature measurement
grate boiler
aspirated thermocouple
spaliny
pomiar
kocioł rusztowy
Opis:
Distribution of the exhaust gas temperature within the furnace of a grate boiler greatly depends on its operating parameters such as output. It has a considerably different character than temperature distributions in other types of boilers (with pulverised or fluidised bed), as it varies considerably across the chamber. Results presented in this paper have been obtained through research of a grate-fired hot water boiler with a nominal rating of some 30 MW. Measurements have been taken by introducing temperature sensors into prearranged openings placed in the boiler side walls. Investigation has been carried out for different output levels. Tests involved thermocouples in ceramic coating and aspirated thermocouples. The latter were used to eliminate influence of radiative heat transfer on measured results. Values obtained with both methods have been cross-checked.
Źródło:
Archives of Thermodynamics; 2015, 36, 3; 3-14
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of power measurement results in the testing of sand mixers
Autorzy:
Smyksy, K.
Wrona, R.
Ziółkowski, E.
Powiązania:
https://bibliotekanauki.pl/articles/382927.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
sand preparation
power measurement
mixer
przerób masy formierskiej
pomiar mocy
mieszalnik
Opis:
Investigations of operating parameters of widely used sand mixers reveal a wide variability range in the values of parameters associated with their power demand. Power efficiency of manufacturing processes has received a great deal of attention lately, which encourages the research efforts to optimise this aspects of operation of machines and installations as well. In the first place these machines and installations have to work properly as a part of the process line- which applies also to moulding sand mixers. Experiments conducted by the authors suggest that the same goal can be achieved at variable energy input levels. To obtain information about the power demands of sand mixers requires the use of highly specialised equipment, methodology and result processing procedures. This study provides a brief characteristic of measurement equipment and results of measurements taken on a unit AG-015 (based on a roller mixer) and a laboratory rotor mixer.
Źródło:
Archives of Foundry Engineering; 2013, 13, 3; 119-122
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Possibility to Improve Resistance of Cast-iron Wood Chip Fine Grinder Liners to Abrasive Wear
Autorzy:
Orłowicz, A. W.
Mróz, M.
Tupaj, M.
Kupiec, B.
Jacek, M.
Radoń, M.
Powiązania:
https://bibliotekanauki.pl/articles/380991.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ductile cast iron
WCCoCr coating
scratch test
żeliwo sferoidalne
powłoka WCCoCr
pomiar zarysowania
Opis:
The paper deals with the issue of potential for improvement of resistance of wood chip fine grinders to abrasive wear by providing them with WCCoCr coating applied with the use of atmospheric plasma spraying (APS). The study focused on establishing parameters of the technological process of spraying a 250–270 μm thick coating onto surface of ductile cast iron castings used to date as grinder linings. The presented data include results of microstructure examination, chemical composition analysis, HV hardness measurements, and scratch tests for both previous and new variant of linings. The obtained scratch test results indicate that the material of the coating is characterized with definitely lower susceptibility to scratching. The scratch made on coating was 75–84 μm wide and 7.2–8.2 μm deep, while the scratch on cast iron was distinctly wider (200–220 μm) and deeper (8.5–12.8 μm). In case of cast iron, the range of variability in scratch width and depth was definitely larger. This can be explained with large difference in hardness of individual components of microstructure of cast iron and significantly larger plastic deformation of cast iron compared to the coating revealed in the course of indenter motion over surfaces of the two materials. It has been found that application of WCCoCr coating offered better resistance of lining surfaces to scratching which can be considered a rationale for undertaking in-service tests.
Źródło:
Archives of Foundry Engineering; 2018, 18, 4; 35-38
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metrological analysis of additively manufactured copies of a fossil skull
Autorzy:
Rucki, Mirosław
Garashchenko, Yaroslav
Kogan, Ilja
Ryba, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2173724.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
additive manufacturing
Madygenerpeton
optical measurement
statistical analysis
produkcja dodatkowa
pomiar optyczny
analiza statystyczna
Opis:
This paper presents the results of a metrological analysis of the additively manufactured (AM) copies of a complex geometrical object, namely the fossil skull of Madygenerpeton pustulatum. This fossil represents the unique remains of an extinct “reptiliomorph amphibian” of high importance for palaeontological science. For this research, the surface was scanned and twelve different copies were 3D-printed using various devices, materials, and AM techniques. The same digitized model was used as a reference to compare with the surfaces obtained by Mitutoyo Coordinate Measuring Machine (CMM) CRYSTA-Apex S 9166 for each copy. The fidelity of the copies was assessed through statistical analysis of the distances between compared surfaces. The methodology provided a good background for the choice of the most accurate copies and the elimination of the less accurate ones. The proposed approach can be applied to any object of complex geometry when reproduction accuracy is to be assessed.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2022, 70, 6; art. no. e143827
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of selected theoretical models of bubble formation and experimental results
Autorzy:
Rząsa, M. R.
Powiązania:
https://bibliotekanauki.pl/articles/240032.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bubble formation
optical tomography
bubble flow measurement
tworzenie pęcherzy
tomografia optyczna
pomiar przepływu
Opis:
Designers of all types of equipment applied in oxygenation and aeration need to get to know the mechanism behind the gas bubble formation. This paper presents a measurement method used for determination of parameters of bubbles forming at jet attachment from which the bubles are displaced upward. The measuring system is based on an optical tomograph containing five projections. An image from the tomograph contains shapes of the forming bubbles and determine their volumes and formation rate. Additionally, this paper presents selected theoretical models known from literature. The measurement results have been compared with simple theoretical models predictions. The paper also contains a study of the potential to apply the presented method for determination of bubble structures and observation of intermediate states.
Źródło:
Archives of Thermodynamics; 2014, 35, 2; 21-36
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies