Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "local power" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Multi-harmonic approach to determine load dependent local flux variations in power transformer cores
Autorzy:
Riemer, B.
Hameyer, K.
Powiązania:
https://bibliotekanauki.pl/articles/141250.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
flux distribution
local flux variations
multi-harmonic FEM
nonlinear FEM
power transformer
Opis:
This paper presents a methodology for the calculation of the flux distribution in power transformer cores considering nonlinear material, with reduced computational effort. The calculation is based on a weak coupled multi-harmonic approach. The methodology can be applied to 2D and 3D Finite Element models. The decrease of the computational effort for the proposed approach is >90% compared to a time-stepping method at comparable accuracy. Furthermore, the approach offers a possibility for parallelisation to reduce the overall simulation time. The speed up of the parallelised simulations is nearly linear. The methodology is applied to a single-phase and a three-phase power transformer. Exemplary, the flux distribution for a capacitive load case is determined and the differences in the flux distribution obtained by a 2D and 3D FE model are pointed out. Deviations are significant, due to the fact, that the 2D FE model underestimates the stray fluxes. It is shown, that a 3D FE model of the transformer is required, if the nonlinearity of the core material has to be taken into account.
Źródło:
Archives of Electrical Engineering; 2015, 64, 1; 129-138
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Distributed generation as efficient measure to improve power generation adequacy
Autorzy:
Andruszkiewicz, Jerzy
Lorenc, Józef
Weychan, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/140385.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
distributed generation
distribution system reliability
generation adequacy
local energy cluster
power supply safety
Opis:
The article concerns safety of power supply for the final consumers, especially its two comprising elements, which are generation adequacy and distribution system re- liability. Generation adequacy has been defined with Loss of Load Probability (LOLP), Loss of Load Expectation (LOLE) and Energy Not Supplied (ENS) indices. Conclusions from generation adequacy forecast prepared by ENSTO-E for Poland compared with other European countries for the years 2020 and 2025 have been discussed along with the resulting threats. Interruptions in energy supply have been characterised by power discontinuity indicator SAIDI. Finally, a reliability and adequacy analysis have been performed for different scenarios of the Polish power system operation in order to assess possibilities of using distributed generation as a backup power source. Based on a simulation model created using the DIgSILENT Power Factory software, the reliability and adequacy calculations have been performed with the probabilistic non-sequential Monte Carlo method and they are followed by a discussion of the obtained results.
Źródło:
Archives of Electrical Engineering; 2019, 68, 2; 373-385
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Architektoniczny projekt turbiny wiatrowej dla lepszej akceptacji społecznej
Architectural wind turbine design for improved social acceptance
Autorzy:
Gawlikowska, A. P.
Moy de Vitry, M.
Chokani, N.
Abhari, R. S.
Powiązania:
https://bibliotekanauki.pl/articles/145807.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
energetyka wiatrowa
akceptacja społeczności lokalnej
partycypacja
architektura
analiza inżynieryjna
psychologia formy
sprawiedliwość proceduralna
wind power
acceptance of local community
participation
architecture
engineering analysis
psychology of form
procedural justice
Opis:
Obecny trend w sektorze energii minimalizacji zależności od paliw kopalnych opiera się na stopniowym rozwoju odnawialnych źródeł energii. W celu utrzymania ekonomicznie wydajnego tempa rozwoju energetyki wiatrowej, w krajach północnej Europy i która jest technologicznie zaawansowana, należy znaleźć rozwiązania dla powiększającej się bariery społecznej. Proponowane jest w tym celu zastosowanie Architektonicznego Projektu Turbiny Wiatrowej. Sugerowane podejście dostosowuje rozwiązania z innych obszarów ludzkiego doświadczenia, które tradycyjnie stosują rozwiązania dla sytuacji, w których następuje interakcja społeczeństwa ze sztucznymi wyrobami i konstrukcjami. Proponowane podejście wykorzystuje doświadczenia z zakresu architektury, urbanistyki i marketingu, uwzględniając jednocześnie kryteria inżynieryjne i możliwości produkcji. Biorąc pod uwagę psychologię formy, został zaproponowany nowy Architektoniczny Projekt Turbiny Wiatrowej. Projekt uwzględnia estetyczne wytyczne dotyczące proporcji oraz bierze pod uwagę elementy psychologiczne np. poczucie bezpieczeństwa i wprowadzenia strefy buforowej między skalą turbiny a skalą otaczającego krajobrazu. W innowacyjny sposób nadaje tożsamość, proponując wprowadzenie dodatkowych funkcji przestrzennych i partycypacyjnego procesu projektowania. Integralność strukturalna nowatorskiej turbiny wiatrowej jest lepsza od tradycyjnej konstrukcji w warunkach obniżonego naprężenia, odkształcenia i wyboczenia oraz posiada większą obciążalność. Dzieje się to kosztem dodatkowej wagi i złożoności elementów strukturalnych, prowadząc również do możliwej nieznacznej poprawy wydajności rocznej produkcji elektryczności i przedłużenia strukturalnej i mechanicznej długości życia turbiny.
The current trend in the energy sector to minimize fossil fuel dependency relies on the gradual growth of renewable energy sources. In order to ensure the further development of wind energy, which is economically efficient and technologically advanced, barriers to social acceptance must be mitigated. The use of Architecturally Designed Wind Turbines is proposed as a novel approach to this challenge. By adapting solutions from other fields of human activity, which traditionally address social interaction with man-made products and structures, the proposed approach uses experiences from architecture, urban planning and marketing, and incorporates them into a well-engineered wind turbine mechanical design and manufacturability. Taking account of the psychology of form, a novel architectural design for wind turbines is proposed, which respects aesthetical guidelines for proportions and gives sense of security and gradual scale buffer zone issues. The innovation in addressing the phenomenon of identity is based on additional social functionalities and a participatory design process. The structural integrity of the novel wind turbine design is superior to the traditional one in terms of decreased stresses, deflection and buckling, and increased load capacity. At the cost of additional weight and complexity, the new design allows for a slight improvement of the annual energy yield and increases the structural and mechanical life expectancy of the turbine.
Źródło:
Kwartalnik Architektury i Urbanistyki; 2016, 61, 4; 65-88
0023-5865
Pojawia się w:
Kwartalnik Architektury i Urbanistyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal power of the TS-300B refrigerator in the aspects of statistical research
Moc cieplna chłodziarki TS-300B w aspekcie badań statystycznych
Autorzy:
Nowak, B.
Łuczak, R.
Powiązania:
https://bibliotekanauki.pl/articles/219985.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
local cooling systems
direct action refrigerator
air conditioning in mines
evaporator thermal power
multiple regression
lokalne systemy chłodnicze
chłodziarka bezpośredniego działania
klimatyzacja kopalń
moc cieplna parownika
regresja wieloraka
Opis:
The article discusses the improvement of thermal working conditions in underground mine workings, using local refrigeration systems. It considers the efficiency of air cooling with direct action air compression refrigerator of the TS-300B type. As a result of a failure to meet the required operating conditions of the aforementioned air cooling system, frequently there are discrepancies between the predicted (and thus the expected) effects of its work and the reality. Therefore, to improve the operating efficiency of this system, in terms of effective use of the evaporator cooling capacity, quality criteria were developed, which are easy in practical application. They were obtained in the form of statistical models, describing the effect of independent variables, i.e. the parameters of the inlet air to the evaporator (temperature, humidity and volumetric flow rate), as well as the parameters of the water cooling the condenser (temperature and volumetric flow rate), on the thermal power of air cooler, treated as the dependent variable. Statistical equations describing the performance of the analyzed air cooling system were determined, based on the linear and nonlinear multiple regression. The obtained functions were modified by changing the values of the coefficients in the case of linear regression, and of the coefficients and exponents in the case of non-linear regression, with the independent variables. As a result, functions were obtained, which were more convenient in practical applications. Using classical statistics methods, the quality of fitting the regression function to the experimental data was evaluated. Also, the values of the evaporator thermal power of the refrigerator, which were obtained on the basis of the measured air parameters, were compared with the calculated ones, by using the obtained regression functions. These statistical models were built on the basis of the results of measurements in different operating conditions of the TS-300B refrigerator, both on the test stand in the manufacturer’s laboratory and in the workings of underground mines. The evaluation of the measurement data distributions, as well as an analysis of the basic descriptive statistics of the mentioned variables were carried out, determining their measures of central tendency, location, dispersion and asymmetry.
Artykuł dotyczy poprawy cieplnych warunków pracy w wyrobiskach górniczych kopalń podziemnych stosujących lokalne systemy chłodnicze. Rozważa się w nim skuteczność schładzania powietrza chłodziarką sprężarkową bezpośredniego działania typu TS-300B. Bardzo często, w wyniku niedotrzymania wymaganych warunków pracy wymienionego systemu chłodzenia powietrza, występują rozbieżności między prognozowanymi, a więc oczekiwanymi efektami jego pracy a rzeczywistością. Dlatego, dla poprawy skuteczności pracy tego systemu, opracowano, pod kątem efektywnego wykorzystania mocy chłodniczej parownika takiej chłodziarki, łatwe w zastosowaniu praktycznym kryteria jakości. Otrzymano je w postaci modeli statystycznych określających wpływ zmiennych niezależnych, tj. parametrów powietrza wlotowego do parownika (temperatury, wilgotności i wydatku objętościowego) oraz parametrów wody chłodzącej skraplacz (temperatury i wydatku objętościowego) na moc cieplną chłodnicy powietrza traktowaną jako zmienna zależna. Równania statystyczne opisujące pracę rozważanego systemu chłodzenia powietrza wyznaczono na podstawie wielorakiej regresji liniowej i nieliniowej. Utworzone funkcje zmodyfikowano poprzez zmianę wartości współczynników w przypadku regresji liniowej oraz współczynników i wykładników w przypadku regresji nieliniowej, przy zmiennych niezależnych. Otrzymano w ten sposób funkcje dogodniejsze w praktycznych wykorzystaniach. Korzystając z metod statystyki klasycznej oceniono jakość dopasowania funkcji regresji do danych eksperymentalnych. Porównano także wartości mocy cieplnych parownika chłodziarki otrzymane na podstawie pomierzonych parametrów powietrza z obliczonymi przy wykorzystaniu utworzonych funkcji regresji. Powyższe modele statystyczne utworzono na podstawie wyników pomiarów w różnych warunków pracy chłodziarki TS-300B, zarówno na stanowisku badawczym w laboratorium jej producenta jak i w wyrobiskach górniczych kopalń podziemnych. Dokonano oceny rozkładów danych pomiarowych oraz przeprowadzono analizę podstawowych statystyk opisowych wymienionych zmiennych określając ich miary przeciętne, pozycyjne, rozrzutu i asymetrii.
Źródło:
Archives of Mining Sciences; 2015, 60, 3; 715-728
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies