Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "flowmeter" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Analysis of Applicability of Flow Averaging Pitot Tubes in the Areas of Flow Disturbance
Autorzy:
Pochwała, S.
Pospolita, J.
Powiązania:
https://bibliotekanauki.pl/articles/221838.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
averaging Pitot tubes
flowmeter
measurement uncertainty
Opis:
The issues connected with the complex design of various facilities, including up-to-date boiler equipment as well as the ways of organizing the space around them, are the reasons why there is often a lack of room for mounting a flowmeter in accordance with the recommendations of manufacturers. In most cases the problem is associated with ensuring sufficient lengths of straight pipe leading into and out of a flowmeter. When this condition cannot be fulfilled, the uncertainty of measurement increases above the value guaranteed by the manufacturer of the flowmeter. This sort of operation problem has encouraged the authors of this paper to undertake research aimed at the analysis of applicability of averaging Pitot tubes in the areas of flow disturbance.
Źródło:
Metrology and Measurement Systems; 2016, 23, 1; 71-84
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrasonic flow measurement with high resolution
Autorzy:
Grzelak, S.
Czoków, J.
Kowalski, M.
Zieliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/221448.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasonic flowmeter
time-to-digital converter
programmable logic device
time measurement
Opis:
The ultrasonic flowmeter which is described in this paper, measures the transit of time of an ultrasonic pulse. This device consists of two ultrasonic transducers and a high resolution time interval measurement module. An ultrasonic transducer emits a characteristic wave packet (transmit mode). When the transducer is in receive mode, a characteristic wave packet is formed and it is connected to the time interval measurement module inputs. The time interval measurement module allows registration of transit time differences of a few pulses in the packet. In practice, during a single measuring cycle a few time-stamps are registered. Moreover, the measurement process is also synchronous and, by applying the statistics, the time interval measurement uncertainty improves even in a single measurement. In this article, besides a detailed discussion on the principle of operation of the ultrasonic flowmeter implemented in the FPGA structure, also the test results are presented and discussed.
Źródło:
Metrology and Measurement Systems; 2014, 21, 2; 305-316
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design and performance of the converging-diverging vortex flowmeter
Autorzy:
Sun, Z.
Powiązania:
https://bibliotekanauki.pl/articles/221011.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
vortex flowmeter
converging-diverging structure
lower limit of measurement
Strouhal number
drag coefficient
Opis:
The converging-diverging structure is introduced to extend the lower limit of measurement of vortex flowmeters. As a compact device, the converging-diverging vortex flowmeter is proposed and designed, and its performance is studied experimentally. It is found that, first of all, an up to 51% extension of the lower measurement limit can be realized through the converging-diverging structure, compared with conventional vortex flowmeters; second, the converging-diverging vortex flowmeter with a trapezoidal bluff body has a larger Strouhal number and smaller pressure loss. The results suggest that the converging-diverging vortex flowmeter provides an alternative device especially suitable for the measurement of low-velocity fluids.
Źródło:
Metrology and Measurement Systems; 2011, 18, 1; 129-136
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental and numerical investigation of thermal flow meter
Autorzy:
Cebula, A.
Powiązania:
https://bibliotekanauki.pl/articles/240345.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
mass flowmeter
heat transfer
uniform heat flux
thermal model
miernik przepływu
wymiana ciepła
model termiczny
Opis:
The paper presents analytical and numerical model calculation results of the temperature distribution along the thermal flow meter. Results show a very good conformity between numerical and analytical model. Apart from the calculation results the experimental investigations are presented. The author performed the test where a temperature of duct wall surface was measured. Therelation between mass flow rate in terms of the duct surface temperature difference was developed.
Źródło:
Archives of Thermodynamics; 2015, 36, 3; 149-160
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Period verification device for ventilation rate standard rods based on a digital thermal flowmeter
Autorzy:
Hu, Jiacheng
Sha, Ying
Cai, Jinhui
Liu, Ying
Liu, Suijun
Powiązania:
https://bibliotekanauki.pl/articles/2052108.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ventilation rate standard rod
period verification
numerical simulation
digital thermal flowmeter
micro-pressure difference adjustment
Opis:
Ventilation rate is a physical index that is strictly controlled during cigarette manufacturing because an abnormal ventilation rate can affect the release of mainstream smoke, tar, and other components harmful to human health. Therefore, the standard rod is used for measuring the ventilation rate, which necessitates accurate and effective periodic inspections. In this study, we designed and built a set of special tobacco ventilation rate standard rods to assess the standard device during its verification period and used a digital thermal flowmeter as the flow standard.We determined the micro-pressure adjustment interval through fluid simulation, and conducted an experimental verification based on the simulation results. At the adjustment point where the differential pressure value was 0 Pa, the period verification device was tested under the standard values of 27.38%, 58.83%, and 71.95%. The results show that the measurement errors of the device are -0.42%, 0.55%, and -0.13% respectively, which all meet the verification regulation requirements and indicate that the device is applicable in practical situations.
Źródło:
Metrology and Measurement Systems; 2022, 29, 1; 231-244
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fully Automated System for Air Velocity Profile Measurement
Automatyczny system do wyznaczania profilu prędkości dla strumienia powietrza
Autorzy:
Kabaciński, M.
Pawliczek, R.
Powiązania:
https://bibliotekanauki.pl/articles/139559.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
air flux measurement
flowmeter
stepper engine drive
virtual instruments
pomiar przepływu powietrza
miernik przepływu
napęd silnika krokowego
przyrządy wirtualne
Opis:
The paper presents the idea of a system for controlling the movement of a flowmeter for air velocity profile measurement. In such a system, due to massive amount of data and limitations of the Data Acquisition Equipment, it is necessary to use moveable sensors. The flowmeter sensor is moved with the use of a linear module with a stepper motor and a tooth-belt drive. The location and speed of the sensor are controlled by a program based on the idea of virtual instrument. The proposed structure allows the user to control operation of the stand and provides automatic measurement. A wide range of velocity and step increments of the stepper motor drive, and flexibility of the virtual instrument software, allow one to create effective measurement systems ensuring sufficiently precise location with optimal time duration of measurement. It is shown that the linear module with tooth-belt is an effective alternative for similar modules with micro-screw drives.
W artykule zaprezentowano system kontroli przemieszczenia przyrządu do pomiaru profilu prędkości strumienia powietrza. W takich systemach z powodu dużej liczby punktów pomiarowych oraz ograniczeń wynikających z urządzeń do akwizycji danych konieczne jest przemieszczanie elementu pomiarowego. Czujnik przepływu jest przesuwany za pomocą modułu liniowego z napędem w postaci paska zębatego i silnika krokowego. Położenie i prędkość czujnika jest kontrolowane za pomocą autorskiego oprogramowania bazującego na idei tzw. „przyrządów wirtualnych”. Układ kontolno-pomiarowy pozwala operatorowi na obsługę stanowiska oraz automatyczne przeprowadzenie pomiarów. Szeroki zakres prędkości obrotowej i dużej rozdzielczości napędu w postaci silnika krokowego oraz elastyczność oprogramowania pozwala tworzyć efektywny system pomiarowy zapewniający dostatecznie dokładną lokalizację punktów pomiarowych przy optymalnym czasie pomiarów. Wykazano, ze napęd liniowy z zastosowaniem paska zębatego i silnika krokowego może być efektywną alternatywą dla podobnych urządzeń ze śruba napędową.
Źródło:
Archive of Mechanical Engineering; 2012, LIX, 4; 435-451
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical analysis of flow averaging tubes in the vortex-shredding regime
Numeryczna analiza drgań czujników uśredniających ciśnienie dynamiczne
Autorzy:
Kabaciński, M.
Lachowicz, C. T.
Pospolita, J.
Powiązania:
https://bibliotekanauki.pl/articles/139634.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
computational fluid dynamics (CFD)
numerical analysis of vibration
averaging Pitot tubes
flowmeter
obliczeniowa dynamika płynów
analiza numeryczna wibracji
rurki uśredniające Pitota
przepływomierz
Opis:
This paper presents a study on flowmeters oscillatory motion when subjected to periodical, enforced vibrations induced by vortex-shedding. The proposed mathematical modelling of flow was compared to corresponding numerical simulation, in form of modal analysis. The frequencies of vortices generation and detachment were calculated for a number of flow velocities in two different flowmeter profile variants. The performed modal evaluation enabled estimating their natural frequencies, and in consequence the acquired data helped us to determine flow velocity for which the analyzed structures were prone to resonant vibrations.
W artykule zaprezentowano proces oddziaływania wymuszonych przepływem płynu wirów na drgania przepływomierzy spiętrzających. Zaproponowany model matematyczny przepływu porównano z wynikami symulacji numerycznych w formie analizy modalnej. Częstotliwość generowania i odrywania się wirów policzono dla różnych predkości przepływu dla czujnika jedno- i dwuprofilowego. Przeprowadzone analizy modalne umożliwiły wyznaczenie ich częstotliwości, a w rezultacie pomogły w wyznaczeniu prędkości przepływu, dla których analizowany czujnik podatny jest na zjawisko rezonansu.
Źródło:
Archive of Mechanical Engineering; 2013, LX, 2; 283-297
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies