Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "floor" wg kryterium: Temat


Tytuł:
Parallel computations of the step response of a floor heater with the use of a graphics processing unit. Part 2: results and their evaluation
Autorzy:
Gołębiowski, J.
Forenc, J.
Powiązania:
https://bibliotekanauki.pl/articles/201532.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
air floor heating
step response computation
parallel computations
GPGPU
Opis:
Using models and algorithms presented in the first part of the article, a spatio-temporal distribution of the step response of a floor heater was determined. The results have been presented in the form of heating curves and temperature profiles of the heater in the selected time moments. The computations results were verified through comparing them with the solution obtained with the use of a commercial program - NISA. Additionally, the distribution of the average time constant of thermal processes occurring in the heater was determined. The analysis of the use of a graphics processing unit in numerical computations based on the conjugate gradient method was done. It was proved that the use of a graphics processing unit is profitable in the case of solving linear systems of equations with dense coefficient matrices. In the case of a sparse matrix, the speed-up depends on the number of its non-zero elements.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 4; 949-954
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uncertainty and accuracy of vision-based tracking concerning stereophotogrammetry and noise-floor tests
Autorzy:
Ngeljaratan, Luna
Moustafa, Mohamed A.
Powiązania:
https://bibliotekanauki.pl/articles/2051854.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
stereophotogrammetry
noise-floor
vision-based tracking
displacement
uncertainty
accuracy
Opis:
This work proposes a systematic assessment of stereophotogrammetry and noise-floor tests to characterize and quantify the uncertainty and accuracy of a vision-based tracking system. Two stereophotogrammetry sets with different configurations, i.e., some images are designed and their sensitivity is quantified based on several assessments. The first assessment evaluates the image coordinates, stereo angle and reconstruction errors resulting from the stereophotogrammetry procedure, and the second assessment expresses the uncertainty from the variance and bias errors measured from the noise-floor test. These two assessments quantify the uncertainty, while the accuracy of the vision-based tracking system is assessed from three quasi-static tests on a small-scaled specimen. The difference in each stereophotogrammetry set and configuration, as indicated by the stereophotogrammetry and noise-floor assessment, leads to a significant result hat the first stereophotogrammetry set measures the RMSE of 3.6 mm while the second set identifies only 1.6 mm of RMSE. The results of this work recommend a careful and systematic assessment of stereophotogrammetry and noise-floor test results to quantify the uncertainty before the real test to achieve a high displacement accuracy of the vision-based tracking system.
Źródło:
Metrology and Measurement Systems; 2022, 29, 1; 75-92
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Shop floor-level control of manufacturing companies: an interview study in Finland
Autorzy:
Tokola, H.
Järvenpää, E.
Salonen, T.
Lanz, M.
Koho, M.
Niemi, E.
Powiązania:
https://bibliotekanauki.pl/articles/407355.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
demand forecasting
shop floor control
production flexibility
inventory control
interview
Opis:
This paper publishes the results of interviews regarding shop-floor-level control of 18 Finnish manufacturing companies. The interviews had 17 open questions relating to demand characteristics, shop floor-level control issues, production flexibility, inventory control, and potential development areas. In order to get insights from the interviews, this paper analyses the answers from the interviews and categorises them into typical answers. The companies that were interviewed are also categorised as small companies with their own end products, subcontractors, or large companies with their own end products, and the emphasis of the analysis is on how companies differ in their shop floor-level control. The results show that different types of companies have different characteristics. Small companies are characterised by constant workflow, seasonal trends in demand, and the use of forecasts. Subcontractors have great daily variation in their demand and processing times. Large companies tend to focus on inventory issues.
Źródło:
Management and Production Engineering Review; 2015, 6, 1; 51-58
2080-8208
2082-1344
Pojawia się w:
Management and Production Engineering Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parallel computations of the step response of a floor heater with the use of a graphics processing unit. Part 1: models and algorithms
Autorzy:
Gołębiowski, J.
Forenc, J.
Powiązania:
https://bibliotekanauki.pl/articles/200428.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
air floor heating
step response
implicit finite difference method
parallel computations
GPGPU
Opis:
The article presents a method of computing the step response of an air floor heater. The method implements parallel algorithms on a graphics processing unit. In the analyzed concrete slab heating ducts are placed. Hot air is transferred through them, thanks to which the heat penetrates into the slab. Heat transfer into the environment takes place on the top surface of the floor by natural convection and radiation. The bottom surface of the slab is thermally insulated. A two-dimensional heat equation was discretized with the use of the implicit finite difference method. In order to solve the obtained system of equations, the conjugate gradient method was used. Moreover, in order to examine the possibility of shortening the computations time, the algorithm of this method was implemented on a graphics processing unit. A computer program, using the CUDA parallel computing platform and linear algebra libraries CUBLAS and CUSPARSE, was developed.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 4; 943-948
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of Urethane Foam Cushioning on Structure-Borne Sound Transfer by a Slab with Panel Flooring
Autorzy:
Mu, R.
Toyoda, M.
Takahashi, D.
Powiązania:
https://bibliotekanauki.pl/articles/176817.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
urethane foam
direct pasted flooring
floor impact sound
sound pressure level
sound insulation performance
Opis:
Urethane foam mattresses are commonly used as cushioning when placing panel flooring on the floor slab of a building. Urethane foam consists of elastic fibres with pores. Both elements can affect the performance of the insulation against impact sounds. However, these effects have not yet been detailed, and they may change if the material properties or constitution of the fibres and pores in the cushioning change. In this paper, we propose an analytical model for use in evaluating the performance of insulation against floor impact sound. This model was used to examine the contribution of the pores versus the elastic fibres to wave transmissions from the flooring surface to the slab. The results reveal that the constitution of the foam (either open or closed cells of pores) and the thickness and hardness of the cushion layer strongly affect the sound insulation performance of the floor.
Źródło:
Archives of Acoustics; 2016, 41, 1; 99-106
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental tests of parameters characterizing the cooperation of powered roof support base and floor of low bearing capacity
Dobór parametrów charakteryzujących postać konstrukcyjną sekcji obudowy zmechanizowanej w aspekcie jej współpracy ze spągiem o małej nośności
Autorzy:
Markowicz, J.
Rajwa, S.
Szweda, S.
Powiązania:
https://bibliotekanauki.pl/articles/218802.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
sekcja obudowy zmechanizowanej
nacisk na spąg
modelowanie
pomiary
powered roof support
pressure on the floor
measurements
Opis:
Results of experimental tests aiming at determination of base pressure on the floor, carried out within “Geosoft” project, are presented. The tests included stand tests carried out with use of unique measuring instrumentation and special hydraulic cushion as well as tests of load of roof support set to load in operating longwall panel. The measurement results confirmed the necessity to consider the 3D model of cooperation of base and floor. Factors having impact on distribution of base pressure on the floor and its maximal value were identified, taking into account the test results.
W artykule przedstawiono zagadnienie eksperymentalnego wyznaczania parametrów charakteryzujących współpracę spągnicy sekcji obudowy zmechanizowanej ze spągiem o małej nośności. Doświadczalna analiza współpracy spągnicy typu katamaran ze spągiem była przedmiotem badań zrealizowanych w ramach międzynarodowego projektu badawczego pt.: “Geomechanika słabych spągów i ociosów” o akronimie GEOSOFT (Geosoft, 2013) współfinansowanego przez Fundusz Badawczy dla Węgla i Stali. Przeprowadzono badania laboratoryjne z wykorzystaniem specjalnie do tego celu skonstruowanej i oprzyrządowanej sekcji obudowy zmechanizowanej typu BW 16/34 POz. Oprzyrządowanie sekcji stanowił układ pomiarowy umożliwiający monitorowanie, wizualizację, a także archiwizację ciśnienia w stojakach sekcji i w siłowniku podpory stropnicy (Rys. 3), cech geometrycznych sekcji (Rys. 4) oraz odkształceń w wybranych punktach elementów sekcji (Rys. 5). Badania laboratoryjne sekcji obudowy BW 16/34 POz przeprowadzono na stanowisku badawczym umożliwiającym obciążanie sekcji poprzez aktywny ruch stropu. Celem modelowania nośności spągu sekcję posadowiono na „poduszce hydraulicznej” (Rys. 7)zbudowanej z 24 siłowników o indywidualnie regulowanych nastawach. Wysokość sekcji rozpartej w stanowisku mieściła się w zakresie wysokości stosowania sekcji w ścianach, w których zaplanowano pomiary dołowe. Stwierdzono, że nawet w przypadku symetrycznego podparcia stropnicy (Rys. 8) obciążenie spągnicy jest niesymetryczne. Zarejestrowany niesymetryczny rozkład nacisku spągnicy na spąg nie został spowodowany ani niesymetrycznym obciążeniem stropnicy, ani nierównomiernym rozkładem nastaw bloków zaworowych w siłownikach poduszki hydraulicznej. Lokalizację miejsca badań dołowych przedstawiono na Rys. 9. Na rysunku 10 przedstawiono wykresy zmian ciśnienia w stojaku lewym i prawym sekcji zarejestrowane podczas biegu ściany. Stwierdzono, że chwilowe obciążenie sekcji jest niesymetryczne, a wartości ciśnienia w stojakach podczas poszczególnych cykli różnią się istotnie. Należy zaznaczyć, że podczas normalnego biegu ściany nie zauważono przejawów niszczenia struktury skał spągowych. Analizując procentowy rozkład obszaru kontaktu spągnicy ze spągiem wyznaczony na podstawie pomiarów w wyrobisku (Rys. 11) stwierdzono, że w przypadku niezawodnionego spągu o małej nośności współpraca spągnicy ze spągiem w tych warunkach jest korzystna, zarówno w aspekcie podporności sekcji, jak również wytężenia podstawowych jej elementów. Wyniki pomiarów, wykonanych w wyrobisku ścianowym, jak również na stanowisku badawczym uzasadniają konieczność modelowania współpracy spągnicy ze spągiem z wykorzystaniem modeli przestrzennych. Przeprowadzone badania stanowiskowe i dołowe umożliwiły zidentyfikowanie czynników istotnie wpływających na współpracę spągnicy ze spągiem.
Źródło:
Archives of Mining Sciences; 2016, 61, 4; 937-948
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling of powered roof support cooperation with the floor of low bearing capacity in the aspect of shaping the section design
Modelowanie współpracy obudowy zmechanizowanej ze spągiem o małej nośności w aspekcie kształtowania postaci konstrukcyjnej sekcji
Autorzy:
Markowicz, J.
Rajwa, S.
Szweda, S.
Powiązania:
https://bibliotekanauki.pl/articles/218946.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
sekcja obudowy zmechanizowanej
nacisk na spąg
modelowanie
pomiary
powered roof support
pressure on the floor
modeling
Opis:
The problem of cooperation of powered roof support with the floor in the aspect of shaping its design is presented. From the analysis of the simplifying assumptions considered so far in the methods for determination of roof support’s base pressure on the floor, it results that they are not satisfied in the case of bases of the catamaran type, commonly used in currently manufactured roof supports. Model of cooperation of the base lying on the floor, prepared by the finite elements method is described and the results of computer simulation of the base action on the floor are given. Considering the results of numerical analyses, the factors influencing the pressure distribution of the base on the floor as well as its maximal value, have been identified.
W artykule przedstawiono zagadnienie współpracy sekcji obudowy zmechanizowanej ze spągiem o małej nośności w aspekcie kształtowania jej postaci konstrukcyjnej. Dotychczas stosowane metody analitycznego, bądź doświadczalnego wyznaczania nacisku spągnicy na spąg były adekwatne do postaci konstrukcyjnej sekcji obudowy zmechanizowanej charakteryzującej się spągnicami dzielonymi. Omówiono założenia upraszczające przyjmowane w metodzie Jacksona, traktujące zespół spągnic sekcji jako ciało idealnie sztywne spoczywające na sprężystym podłożu. Opisano również przykłady modelowania współpracy spągnicy sekcji obudowy zmechanizowanej ze spągiem, w których problem interakcji spągnicy i spągu potraktowano jako zadanie płaskie, przyjmując liniowo sprężystą charakterystykę spągu. Na Rys. 1 i 2 przedstawiono odkształcone modele spągnicy spoczywającej na węglowym spągu oraz rozkład nacisku spągnicy na spąg. Modele spągnicy, zbudowane metodą elementów skończonych, złożone były z elementów powłokowych o zmiennej grubości. Jakkolwiek stosowanie płaskich modeli interakcji spągnicy i spągu umożliwiło analizę rozkładu nacisku spągnicy na spąg, to modele te nie są adekwatne w przypadku spągnic typu katamaran, gdyż nie można przyjąć założenia niezależnego schematu obciążenia każdej ze spągnic. Wyniki pomiarów, wykonanych w wyrobisku ścianowym, jak również na stanowisku badawczym uzasadniają konieczność modelowania współpracy spągnicy ze spągiem z wykorzystaniem modeli przestrzennych. Model geometryczny spągnicy sekcji obudowy zmechanizowanej typu BW 16/34 POz i spągu, z podziałem na elementy skończone przedstawiono na Rys. 3. Model spągnicy wiernie odwzorowuje jej postać geometryczną, łącznie z nakładkami wzmacniającymi najbardziej wytężone obszary spągnicy. Przyjęto sprężysto-plastyczną charakterystykę spągu z liniowym umocnieniem (Rys. 4). Przykładowe obciążenie zewnętrzne spągnicy (Tabela 1) przedstawiono na Rys. 5. Wykresy zamieszczone na Rys. 6-10 świadczą o istotnie różnych rozkładach nacisku lewej i prawej części spągnicy na spąg. Przeprowadzone symulacje komputerowe umożliwiły zidentyfikowanie czynników istotnie wpływających na współpracę spągnicy ze spągiem. Spośród czynników zależnych od projektanta sekcji na uwagę zasługuje jej postać konstrukcyjna. Projektując sekcję należy dążyć do uzyskania równomiernego rozkładu nacisku na powierzchni spągnicy, co jest równoznaczne z wymuszeniem zwrotu składowej poziomej obciążenia sekcji w stronę zawału. Zwrot tej siły, zależny między innymi, od względnych przemieszczeń stropnicy i stropu można kształtować poprzez odpowiednie zaprojektowanie toru ruchu stropnicy. W podsumowaniu stwierdzono, że postać konstrukcyjna sekcji powinna podczas konwergencji stropu, wymuszać zwrot siły tarcia w stronę zawału. Ponadto podporność wstępną i roboczą sekcji należy ustalić na możliwie najniższym poziomie, zapewniającym jednakże poprawną współpracę sekcji ze stropem wyrobiska. Należy również dążyć do zaprojektowania spągnicy o możliwie największej powierzchni kontaktu ze spągiem poprzez jej maksymalne wydłużenie w kierunku czoła ściany. W przypadku słabych spągów należy rozważyć możliwość zastosowania sekcji dwuszeregowych z lemniskatowym prowadzeniem stropnicy zamiast sekcji jednoszeregowych z uwagi na korzystniejszy rozkład nacisku na spąg w tych sekcjach.
Źródło:
Archives of Mining Sciences; 2017, 62, 1; 177-188
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Market research concerning functional and material solutions employed in nursery facilities
Badanie rynku w zakresie rozwiązań funkcjonalno-materiałowych obiektów żłobkowych
Autorzy:
Radziszewska-Zielina, E.
Grabowska, W.
Szewczyk, B.
Powiązania:
https://bibliotekanauki.pl/articles/230295.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
badanie rynku
żłobek
rozwiązanie funkcjonalno-materiałowe
materiał wykończeniowy
podłoga
market research
nursery
functional-material solution
finishing material
floor
Opis:
In Poland, nursery capacity does not meet the growing demand, which in practice results in a reduction of technical requirements for such facilities. As a result, many non-functional child care facilities for children up to the age of three have been established. Extreme cases include facilities that do not meet the provisions of the construction law, good design practice, not to mention the expectations of the employees of these institutions and the parents of children attending them. Badly designed nurseries are, primarily, a problem for their youngest users. This state of affairs can be blamed on the low level of knowledge in this area, as well as few available studies on topics associated with nursery facilities that can familiarise readers with legal aspects, administrative procedures, examples of good functional and material solutions of said facilities, in addition to there being little information about the needs and preferences of people directly interested in this topic. The aim of the article was to analyse the expectations and preferences of users of nursery facilities in the field of functional and material solutions. Based on a survey conducted among employees of nurseries and parents enrolling their children to these institutions, guidelines were defined that would allow for the design of an optimal nursery facility meeting market expectations.
W Polsce liczba miejsc w żłobkach nie zaspakaja rosnącego zapotrzebowania, co w praktyce spowodowało zmniejszenie wymagań lokalowych dla tego typu obiektów. W wyniku tego powstało wiele niefunkcjonalnych miejsc opieki nad dziećmi w wieku do lat trzech. Skrajnymi przypadkami są obiekty niespełniające przepisów prawa budowlanego, dobrej praktyki projektowania, nie wspominając o zaspokojeniu oczekiwań pracowników tych instytucji oraz rodziców dzieci do nich uczęszczających. Źle zaprojektowane żłobki są przede wszystkim problemem dla ich najmłodszych użytkowników. Taka sytuacja ma miejsce m.in. ze względu małą wiedzę w tym zakresie, nieliczne dostępne opracowania o tematyce żłobkowej przybliżające zarówno przepisy prawne, procedury administracyjne, przykłady dobrych rozwiązań funkcjonalno-materiałowych obiektów żłobkowych jak i nieliczne informacje o potrzebach i preferencjach osób bezpośrednio zainteresowanych tym tematem. Celem artykułu była analiza oczekiwań i preferencji użytkowników obiektów żłobkowych w zakresie rozwiązań funkcjonalno-materiałowych. Na podstawie przeprowadzonych badań opinii pracowników żłobków i rodziców oddających dzieci pod opiekę tych instytucji określono wytyczne, które pozwolą na zaprojektowanie optymalnego obiektu żłobkowego, odpowiadającego oczekiwaniom rynku.
Źródło:
Archives of Civil Engineering; 2019, 65, 1; 197-212
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental study of the strip coal pillar models failure with different roof and floor conditions
Autorzy:
Qu, Xiao
Chen, Shaojie
Yin, Dawei
Liu, Shiqi
Powiązania:
https://bibliotekanauki.pl/articles/2073871.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kopalnia
filar węglowy
górnictwo odkrywkowe
“roof-strip coal pillar-floor” combined specimen
failure characteristics
acoustic emission
laboratory experiment
Opis:
In order to study the failure mechanism and characteristics for strip coal pillars, a monitoring device for strip coal pillar uniaxial compression testing was developed. Compression tests of simulated strip coal pillars with different roof and floor rock types were conducted. Test results show that, with increasing roof and floor strength, compressive strength and elastic modulus of “roof-strip coal pillar-floor” combined specimens increase gradually. Strip coal pillar sample destruction occurs gradually from edge to the interior. First macroscopic failure occurs at the edge of the middle upper portion of the specimen, and then develops towards the corner. Energy accumulation and release cause discontinuous damage in the heterogeneous coal-mass, and the lateral displacement of strip coal pillar shows step and mutation characters. The brittleness and burst tendency of strip coal pillar under hard surrounding rocks are more obvious, stress growth rate decreases, and the rapid growth acoustic emission (AE) signal period can be regarded as a precursor for instability in the strip coal pillar. The above results have certain theoretical value for understanding the failure law and long-term stability of strip coal pillars.
Źródło:
Archives of Mining Sciences; 2021, 66, 3; 475--490
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A case study of pre-service cracks in the concrete decks of a two-level basement car park
Studium przypadku zarysowania dwupoziomowego parkingu podziemnego
Autorzy:
Kossakowski, P. G.
Ślusarczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/231057.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
beton
zapobieganie uszkodzeniu
strop betonowy
rysa
garaż podziemny
studium przypadku
concrete
failure prevention
concrete floor
crack
basement car park
Opis:
This paper deals with the prevention of failure of structural elements made of reinforced concrete. It discusses preservice cracks in the concrete decks of an underground parking facility. The cracks were assessed by analyzing their morphology. The results were used to determine the crack causes and the mechanisms of their initiation and growth. Some design solutions to prevent or reduce the occurrence of pre-service cracks are also presented.
Przy realizacji budynku na drogim gruncie standardem jest wykonywanie kondygnacji podziemnych. Są one niezbędne chociażby ze względu na zapewnienie odpowiedniej liczby miejsc parkingowych. Niejednokrotnie zdarza się, że poziomy podziemne dochodzą do granic działki. Wymaga to zastosowania odpowiedniej technologii realizacji. Najczęściej w tym celu jest wykorzystywany zamknięty układ ścian szczelinowych. Przedsięwzięcia tego typu wymagają zarówno dobrych projektów jak i starannego wykonawstwa. Ich złożoność sprzyja powstawaniu różnego typu usterek. W artykule na stosownym przykładzie opisano jedną z możliwych. Dotyczy ona niepożądanego zarysowania podziemnych stropów parkingu ujawnionego tuż przed rozpoczęciem eksploatacji.
Źródło:
Archives of Civil Engineering; 2017, 63, 2; 79-97
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of the derailment safety index Y/Q of the low-floor tram bogies with different types of guidance of independently rotating wheels
Autorzy:
Opala, M.
Powiązania:
https://bibliotekanauki.pl/articles/223583.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
derailment safety
safety
simulation
independently rotating wheels
low-floor tram
wykolejenie
bezpieczeństwo
symulacja
niezależnie obracające się koła
tramwaj niskopodłogowy
Opis:
Modern tram designs use different conceptions of how to implement the low-floor functionality. The key construction part is the bogie running gear which has to accommodate the lower part of the tram body. To adjust the low-floor level, many low-floor tram bogies have different types of guidance of independently rotating wheels with no central axle between the two wheels. Lack of self-steering mechanism in the form of central axle coupling or an external guiding device creates several inherent problems, such as insufficient guiding and excessive wear. Another important context is the safety against derailment when the vehicle negotiates a curved track. In this study the dynamic behaviour of non-powered bogies with different types of guidance of independently rotating wheels are presented using computer simulation models. The simulation results of the Y/Q index are compared for the two track configurations (curved and tangent sections) and four different kinds of bogie running gear.
Źródło:
Archives of Transport; 2016, 38, 2; 39-47
0866-9546
2300-8830
Pojawia się w:
Archives of Transport
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Integrated monitoring system of production processes
Autorzy:
Oborski, P.
Powiązania:
https://bibliotekanauki.pl/articles/407303.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
production process
integrated monitoring system
Cyber-Physical-Systems
management systems
process monitoring
shop floor control
company IT systems
multiagent systems
Opis:
Integrated monitoring system for discrete manufacturing processes is presented in the paper. The multilayer hardware and software reference model was developed. Original research are an answer for industry needs of the integration of information flow in production process. Reference model corresponds with proposed data model based on multilayer data tree allowing to describe orders, products, processes and save monitoring data. Elaborated models were implemented in the integrated monitoring system demonstrator developed in the project. It was built on the base of multiagent technology to assure high flexibility and openness on applying intelligent algorithms for data processing. Currently on the base of achieved experience an application integrated monitoring system for real production system is developed. In the article the main problems of monitoring integration are presented, including specificity of discrete production, data processing and future application of Cyber-Physical-Systems. Development of manufacturing systems is based more and more on taking an advantage of applying intelligent solutions into machine and production process control and monitoring. Connection of technical systems, machine tools and manufacturing processes monitoring with advanced information processing seems to be one of the most important areas of near future development. It will play important role in efficient operation and competitiveness of the whole production system. It is also important area of applying in the future CyberPhysical-Systems that can radically improve functionally of monitoring systems and reduce the cost of its implementation.
Źródło:
Management and Production Engineering Review; 2016, 7, 4; 86-96
2080-8208
2082-1344
Pojawia się w:
Management and Production Engineering Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical analysis for frequency and displacement improvement of a long span floor building
Autorzy:
Supriyadi, Bambang
Powiązania:
https://bibliotekanauki.pl/articles/1849764.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
częstotliwość podstawowa
przemieszczenie
obciążenie dynamiczne
podłoga
rozpiętość duża
analiza numeryczna
fundamental frequency
displacement
dynamic load
long-span
floor
numerical analysis
Opis:
In the last decade many buildings such as multipurpose buildings, malls, auditoriums, sports halls which have long-span building floor structure. Various research results indicate that in general long-span concrete floor structures have a fundamental frequency of less than 7 Hz. This will risk a resonance if this floor receives dynamic loads of people jogging to follow the song with a frequency of 2-3 Hz. This research was conducted to numerically analyze the long-span building floor model using SAP2000, to determine the fundamental frequency and maximum displacement of the floor structure model. It was also investigated how to increase its fundamental frequency and reduce the maximum displacement. The results have shown that the numerical analysis of the plate model long-span floor building using SAP2000 produces a fundamental frequency of 5.19 Hz. Model III with Reinforcing double equal angles (84x37x10x2.5) steel truss provides the best results, increases the fundamental frequency to be 7.93 Hz, and with a variety of static and dynamic loads, decreases the value of the displacement and far from the allowable displacement.
Źródło:
Archives of Civil Engineering; 2020, 66, 4; 651-660
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on mine seal stability under explosion load and ground pressure in underground coal mines
Autorzy:
Cheng, Jianwei
Song, Wanting
Jing, Yi
Zhang, Xixi
Korzec, Marek
Borowski, Marek
Wang, Yue
Powiązania:
https://bibliotekanauki.pl/articles/218944.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kopalnia węgla
symulacja numeryczna
dłutowanie
seals in underground coal mines
numerical simulation
slotting
ground pressure
roof to floor moving convergence
damage level
Opis:
The mine seals in coal mines with a good impact resistance and air tightness are mainly used to isolate abandoned mining areas from active workings. For one thing, it can prevent the leakage of harmful gases, such as toxic gas from abandoned areas. For another, once an underground mine explosion happens, it can effectively block the spread of the explosion between the abandoned mining areas and the active workings. Hence, it is of great significance to study the explosion-proof performance and mechanical properties of the mine seals. First of all, the effect of slotting on the stability of the seals in coal mines under explosion load was explored in this study. By numerical simulations, the mechanical response characteristics of the seals with or without cutting a slot under the explosion load were compared in detail. The results show that slotting improved the stress concentration at the contact surface of surrounding rock by transferring partial impact received by mine seals to the surrounding rocks, thus, to achieve the effect of buffering explosion impact. Besides, such effect will be enhanced with increasing cutting depth into rock, and will stabilize when the depth is 20 cm. On this basis, the mechanical properties and damage of the seals constructed by different materials (standard brick and #C40 concrete) under the explosion load were compared. It was found that once a slot was set, the maximum deformation of the concrete seal was reduced, while the maximum deformation of the brick seal increased. Since the non-deformability of the concrete seal is obviously stronger than that of the brick seal, with the impact resistance stronger than that of the brick seal, the concrete seal is more suitable for slotting. Moreover, the damage of the seals in underground coal mines under the strata ground pressure was studied; the results of which show that the damage state under the ground pressure can be divided into 3 levels, i.e. no damage, minor damage and rapid development of damage. Meanwhile, it was found that the prestressed structure fordem by the ground pressure at the level of no damage can enhance the protective effect of the seals in coal mines. However, when the ground pressure was further developed, the seal itself was destroyed and the protective effect was lost. In addition, the influence of roof to floor moving convergence, a deformation parameter of the roadway, on the seals was also investigated. The results show that the ground pressure and roof-to-floor convergence act on the seals in coal mines in the same way, thus roof to floor moving convergence can replace the ground pressure to analyze other related mechanical properties of the seals in coal mines in the future researches.
Źródło:
Archives of Mining Sciences; 2020, 65, 1; 71-87
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of the tie reinforcement on the development of a collapse caused by the failure of an edge column in RC flat slab system
Wpływ zbrojenia wieńcowego na rozwój katastrofy spowodowanej awarią słupa krawędziowego w ustroju płytowo - słupowym
Autorzy:
Buda-Ożóg, Lidia
Zięba, Joanna
Sieńkowska, Katarzyna
Nykiel, Damian
Powiązania:
https://bibliotekanauki.pl/articles/2203446.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
zbrojenie
zbrojenie wieńcowe
katastrofa postępująca
słup krawędziowy
strop słupowo-płytowy
odkształcenie
reinforcement
tie reinforcement
progressive failure
edge column
slab-column floor
deformation
Opis:
RC flat slabs are one of the most popular and effective methods of shaping plates in buildings. Although failures of entire structures are relatively rare, they cannot be excluded from the occupancy cycle of the facility. The research analysis presented in this paper is an attempt to understand more precisely the phenomena that occur in the RC flat slab system and to assess the influence of the additional protection of the flat slabs against progressive collapse in the case of failure of one of the supports. The results were obtained from destructive experimental investigations of a flat reinforced concrete slab made in scale 1:3. The collapse in the analysed model was simulated by removing three edge columns and additional loading by means of hydraulic actuator. In place of the columns removed, differential tie reinforcement was applied. The results obtained confirm that the structure achieved a much higher ultimate load than the one resulting from the design calculations.
Układy słupowo - płytowe są jedną z najbardziej popularnych i efektywnych metod kształtowania płyt w budynkach. Mimo że awarie całych konstrukcji zdarzają się stosunkowo rzadko, nie można ich wykluczyć z cyklu użytkowania obiektu. Przedstawione w niniejszej pracy analizy badawcze są próbą dokładniejszego zrozumienia zjawisk zachodzących w układzie płaskich płyt żelbetowych oraz oceny wpływu zastosowanego dodatkowego zbrojenia płyt przed postępującym zawaleniem w przypadku zniszczenia jednej z podpór. Wyniki uzyskano na podstawie niszczących badań doświadczalnych stropu żelbetowego wykonanego w skali 1:3. W analizowanym modelu symulowano zawalenie się stropu poprzez usunięcie trzech słupów krawędziowych i dodatkowe obciążenie siłownikiem hydraulicznym. W miejsce usuniętych słupów zastosowano zróżnicowane zbrojenie cięgnowe. Uzyskane wyniki potwierdzają, że konstrukcja osiągnęła znacznie większe obciążenie granicznie nośne niż to, które wynikało z obliczeń projektowych.
Źródło:
Archives of Civil Engineering; 2023, 69, 1; 39--54
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies