Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "fast Fourier transform" wg kryterium: Temat


Wyświetlanie 1-8 z 8
Tytuł:
High Performance DIF-FFT Using Dissimilar Partitioned LUT Based Distributed Arithmetic
Autorzy:
Cheepurupalli, Kusma Kumari
Charan, Muntha
Rao, Jammu Bhaskara
Noor, Mahammad S.
Powiązania:
https://bibliotekanauki.pl/articles/2055270.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
fast Fourier transform
adders
distributed arithmetic
DSP
Opis:
Real-time data processing systems utilize Digital Signal Processing (DSP) functions as the base modules. Most of the DSP functions involve the implementation of Fast Fourier Transform (FFT) to convert the signals from one domain to another domain. The major bottleneck of Decimation in frequency - Fast Fourier Transform (DIF-FFT) implementation lies in using a number of Multipliers. Distributed arithmetic (DA) is considered as one of the efficient techniques to implement DIF-FFT. In this approach, the multipliers are not used. The proposed technique exploits the very advantage of the look-up table by storing the Twiddle factors, thereby avoiding the multipliers required in the butterfly structure. DIF-FFT using Distributed Arithmetic (DIF-FFT DA) models, with different adders such as Ripple carry adder (RCA), Carry-lookahead adder (CLA), and Sklansky prefix graph adder, are proposed in this paper. The three proposed models are synthesized using Cadence 6.1 EDA tools with a 45nm CMOS technology. Compared to the traditional method, it is observed that the area is improved by 53.11%, 53.35%, and 50.15%, power is improved by 42.31%, 42.52%, and 40.39%, and delay is improved by 45.26%, 45.42%, 41.80%, respectively.
Źródło:
International Journal of Electronics and Telecommunications; 2021, 67, 4; 631--637
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of Surface Profile and Surface Roughness of Fibre-Optic Interconnect by Fast Fourier Transform
Autorzy:
Lin, C. S.
Yang, S. W.
Lin, H. L.
Li, J. W.
Powiązania:
https://bibliotekanauki.pl/articles/221117.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
surface profile
surface roughness
fibre end-face
fast Fourier transform
Opis:
This study proposes a surface profile and roughness measurement system for a fibre-optic interconnect based on optical interferometry. On the principle of Fizeau interferometer, an interference fringe is formed on the fibre end-face of the fibre-optic interconnect, and the fringe pattern is analysed using the Fast Fourier transform method to reconstruct the surface profile. However, as the obtained surface profile contains some amount of tilt, a rule for estimating this tilt value is developed in this paper. The actual fibre end-face surface profile is obtained by subtracting the estimated tilt amount from the surface profile, as calculated by the Fast Fourier transform method, and the corresponding surface roughness can be determined. The proposed system is characterized by non-contact measurement, and the sample is not coated with a reflector during measurement. According to the experimental results, the difference between the roughness measurement result of an Atomic Force Microscope (AFM) and the measurement result of this system is less than 3 nm.
Źródło:
Metrology and Measurement Systems; 2017, 24, 2; 381-390
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Comparative Analysis of Evolutionary Algorithms for Synthesis of Scanned Linear Array of Mutually Coupled Parallel Dipole Antennas
Autorzy:
Patidar, H.
Mahanti, G. K.
Muralidharan, R.
Powiązania:
https://bibliotekanauki.pl/articles/227212.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
antenna array
comparative analysis
evolutionary algorithms
inverse fast Fourier transform
scanning
Opis:
This paper presents a comparative analysis of three evolutionary algorithms, namely, Backtracking Search Algorithm, Cuckoo Search Algorithm and Artificial Bee Colony Algorithms for synthesis of a scanned linear array of uniformly spaced parallel half wavelength dipole antennas. Here, antenna parameters, namely Side Lobe Level, reflection coefficient and wide null depth are taken into consideration for comparison between algorithms. In addition to it, statistical parameters, namely best fitness value, mean and standard deviation of the fitness values obtained from algorithms are compared. Mutual coupling that exists among the antenna elements is included in obtaining radiation patterns and the self-impedances along with the mutual impedances are calculated by induced Electro-Motive Force method. Two different examples are shown in this paper to validate the effectiveness of the utilized approach. Although, this approach is applied to a linear array of dipole antennas; this can be utilized for other array geometries as well.
Źródło:
International Journal of Electronics and Telecommunications; 2017, 63, 2; 151-157
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fault diagnosis method for an aerospace generator rotating rectifier based on dynamic FFT technology
Autorzy:
Feng, Sai
Cui, Jiang
Zhang, Zhuoran
Powiązania:
https://bibliotekanauki.pl/articles/1849142.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
aerospace generator
rotating rectifier
fault diagnosis
dynamic Fast Fourier Transform
feature extraction
Opis:
A fault diagnosis method for the rotating rectifier of a brushless three-phase synchronous aerospace generator is proposed in this article. The proposed diagnostic system includes three steps: data acquisition, feature extraction and fault diagnosis. Based on a dynamic Fast Fourier Transform (FFT), this method processes the output voltages of aerospace generator continuously and monitors the continuous change trend of the main frequency in the spectrum before and after the fault. The trend can be used to perform fault diagnosis task. The fault features of the rotating rectifier proposed in this paper can quickly and effectively distinguish single and double faulty diodes. In order to verify the proposed diagnosis system, simulation and practical experiments are carried out in this paper, and good results can be achieved.
Źródło:
Metrology and Measurement Systems; 2021, 28, 2; 269-288
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The heat transfer and flow structure analyses of low concentration copper nanofluids in a strong magnetic field
Autorzy:
Roszko, A.
Fornalik-Wajs, E.
Powiązania:
https://bibliotekanauki.pl/articles/175547.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
nanofluids
heat transfer
flow structure
fast Fourier transform
Nusselt number ratio
thermomagnetic Rayleigh number
Opis:
Main aim of this paper was to analyze the influence of strong magnetic field on the enhancement or suppression of nanofluids transport processes. The second objective was to determine how the flow structure changed under the influence of a magnetic field. Analyzed diamagnetic nanofluids composed of distilled water and the copper nanoparticles of 40–60 nm size in three different concentrations (50, 500, and 1000 ppm). The experimental enclosure position in the magnet test section caused the most intricate interaction of the acting forces: the gravitational and magnetic buoyancy ones, and made the interpretation of results very difficult. The Nusselt number ratio and the thermomagnetic Rayleigh number were determined for heat transfer analysis, while the fast Fourier transform was performed for the nanofluid flow structure analysis. Spectral analysis for all examined nanofluids was presented. Influence of nanoparticles concentration was clearly visible, while the direct impact of magnetic field on the heat transfer and flow structure should be still investigated.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2015, 128; 29-42
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of ADC Resolution on Low-Frequency Electrical Time-Domain Impedance Spectroscopy
Autorzy:
Namin, R. L.
Ashtiani, S. J.
Powiązania:
https://bibliotekanauki.pl/articles/221144.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electrical impedance spectroscopy
analogue-to-digital converter
Ramp signal
fast Fourier transform
Nyquist plot
Opis:
In this paper, the effect of the resolution of an analogue-to-digital converter (ADC) on the accuracy of timedomain low-frequency electrical impedance spectroscopy is examined. For the first time, we demonstrated that different wideband stimuli signals used for impedance spectroscopy have different sensitivities to the resolution of ADC used in impedance spectroscopy systems. We also proposed Ramp and Half-Gaussian signals as new wideband stimulating signals for EIS. The effect of ADC resolution was studied for Sinc, Gaussian, Half-Gaussian, and Ramp excitation signals using both simulation and experiments. We found that Ramp and Half-Gaussian signals have the best performance, especially at low frequencies. Based on the results, a wideband electrical impedance spectroscopy circuit was implemented with a high accuracy at frequencies bellow 10 Hz.
Źródło:
Metrology and Measurement Systems; 2017, 24, 2; 425-436
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design and computation of a lightning protection system in an urban 110 kV substation
Autorzy:
Taha, Mohammed Ibrahim
Li, Lin
Wang, Ping
Powiązania:
https://bibliotekanauki.pl/articles/140973.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
CDEGS software
fast Fourier transform (FFT)
IEC 62305-3
lightning protection system (LPS)
NFPA 780 level 1
Opis:
A lightning protection system (LPS) of an urban 110 kV substation is designed and analysed according to NFPA 780 and IEC 62305-3 standards. The analysis of the LPS is established on the value of risk assessment. The total area of the plant is described by one soil layer with uniform resistivity. This study aims to improve the understanding of an unexpected manner of the grounding system beneath lightning currents by clarifying the basic concepts of the lightning protection level and the new design procedure in this paper was clarified according to NFPA-780 level 1 for a lightning protection system. The program is integrated with the CDEGS software, which provides effective geometrical modeling with object and result visualization. Furthermore, module and automated fast Fourier transform (FFT) is implemented in this study to simulate electromagnetic fields in the time and frequency domains. These current values are compared to the desired protection levels within the standards. The study results show that for the improved protection of the system against lightning, the total power grid must be considered as a source of improvement for studying shielding influence and the protection levels provided inside this substation.
Źródło:
Archives of Electrical Engineering; 2020, 69, 3; 723-738
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stator winding fault detection of permanent magnet synchronous motors based on the bispectrum analysis
Autorzy:
Pietrzak, Przemysław
Wolkiewicz, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/2173641.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
fault diagnosis
condition monitoring
inter-turn short circuits
permanent magnet synchronous motor
bispectrum
fast Fourier transform
błędna diagnoza
monitorowanie stanu
zwarcia międzyzwojowe
silnik synchroniczny z magnesami trwałymi
bispektrum
szybka transformata Fouriera
Opis:
The popularity of high-efficiency permanent magnet synchronous motors in drive systems has continued to grow in recent years. Therefore, also the detection of their faults is becoming a very important issue. The most common fault of this type of motor is the stator winding fault. Due to the destructive character of this failure, it is necessary to use fault diagnostic methods that facilitate damage detection in its early stages. This paper presents the effectiveness of spectral and bispectrum analysis application for the detection of stator winding faults in permanent magnet synchronous motors. The analyzed diagnostic signals are stator phase current, stator phase current envelope, and stator phase current space vector module. The proposed solution is experimentally verified during various motor operating conditions. The object of the experimental verification was a 2.5 kW permanent magnet synchronous motor, the construction of which was specially prepared to facilitate inter-turn short circuits modelling. The application of bispectrum analysis discussed so far in the literature has been limited to vibration signals and detecting mechanical damages. There are no papers in the field of motor diagnostic dealing with the bispectrum analysis for stator winding fault detection, especially based on stator phase current signal.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2022, 70, 2; art. no. e140556
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies