Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "critical speed" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Collosion and Absorption Behaviors of Inclusions on Refractory
Autorzy:
Ding-Guo, Z.
Ming, G.
Xin, L.
Shu-Huan, W.
Powiązania:
https://bibliotekanauki.pl/articles/352357.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
inclusion
refractory wall surface
collision and absorption
critical stay speed
Opis:
The paper is dedicated to analysis the inclusion behavior in steel using theoretical calculation and simulation of water. The aim is to establish collision and absorption model of inclusions on refractory. The article discusses the variation of critical stay speed and critical shear with the radius of inclusions in the process of colliding, rebounding and absorbing. The results show the critical stay speed and critical shear of alumina respectively surpasses 1 cm·s-1 and 1 N·m-2, while titanium dioxide separately exceeds 4 cm·s-1 and 10 N·m-2 for the inclusions that radius is less than 2.5 μm. If the inclusions occur rebound after colliding, the inclusions that radius is less than 7 μm will still be absorbed by the surface, while the inclusions that radius is more than 10 μm can easily reenter the steel. The model coincides with the water simulation results and it is of good adaptability.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 2A; 857-863
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of critical wind speed on the basis of roof blow-off
Oszacowanie krytycznej prędkości wiatru na podstawie zerwanego dachu
Autorzy:
Chmielewski, T.
Kaleta, B.
Nowak, H.
Powiązania:
https://bibliotekanauki.pl/articles/230821.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
burza wiatrowa
derecho
uszkodzenie budynku
zdmuchnięcie dachu
współczynnik aerodynamiczny
prędkość krytyczna
prędkość wiatru
wind storm
building damage
roof blow-off
aerodynamic coefficient
critical speed
wind speed
Opis:
W dniach 11-12 sierpnia 2017 r. nad Polską przeszła rozległa burza wiatrowa. Cała burza obejmowała obszar około 540 km od Wrocławia, przez Poznań, Bydgoszcz, wzdłuż Gdyni i Gdańska oraz część Wybrzeża. Z dużą siłą wiatru przeszła przez trzy województwa: Wielkopolskie, Kujawsko-Pomorskie i Pomorskie. Pomierzone prędkości wiatru osiągnęły 130 km/h, powodując duże zniszczenia na swojej drodze, a w jednej stacji synoptycznej, tj. w Elblągu prędkość wiatru przekroczyła 150 km/h. Maksymalne prędkości wiatru zostały pomierzone w następujących miejscowościach: Chojnice: 31.2 m/s (112 km/h), Gniezno: 34.8 m/s (125 km/h), Chrząstowo/Noteć: 36.0 m/s (130 km/h), Elbląg: 42,0 m/s (151 km/h). Ścieżka przejścia burzy była w przybliżeniu liną prostą, miała ponad 400 km długości i w trzech miejscach oddalonych około 70 km wiatr wiał z prędkością 100 km/, czyli burza spełniała kryteria burzy „derecho”. Burza wiatrowa spowodowała ofiary ludzkie i ogromne straty materialne opisane w pracy [8]. Celem artykułu jest oszacowanie krytycznej prędkości wiatru w zdarzeniu zerwania dachu jednopiętrowego ceglanego budynku podczas burzy wiatrowej w dniu 11 sierpnia 2017 r. W tym celu obliczono ciężar konstrukcji i pokrycia dachu oraz oszacowano siłę połączenia między murłatami i ściankami kolankowymi. Wzajemne porównanie obu tych sił umożliwiło obliczenie krytycznej prędkości wiatru, która okazała się znacznie większa od wartości pomierzonych na stacjach meteorologicznych.
Types of wind storms in Poland and examples of economic damage, threats to human life and health caused by two extreme wind events are presented. Then, a house with the roof blown-off during the derecho wind storm in Poland on August 11-12, 2017, is considered. Based on the rafter framing of the house, i.e. wooden roof structure elements and roof covered, the weight of the roof is calculated. Two cases of the strong connection between rafter plates and knee walls are estimated. With the estimation of connection strength between rafter plates and knee walls, it was possible to calculate the total force required to blow-off the roof of the house. Next, an aerodynamic force acting on the house is calculated using pressure coefficients for a low-rise house with a gable roof. The pressure coefficients were taken from the Tokyo Polytechnic University aerodynamic database. The aerodynamic force acting on the roof blown-off was calculated for a low-rise building with a gable roof for similar ratios for length, width, and height. Three wind directions, for the unknown orientation of the building, were considered, i.e. the wind direction perpendicular, parallel, and oblique to the gable wall. By comparison, the aerodynamic force with the total force required to blow-off the roof of the house, it was possible to calculate the critical wind speed needed for the roof blown-off. This wind speed is much bigger than measured by meteorological stations on the path of the derecho.
Źródło:
Archives of Civil Engineering; 2020, 66, 3; 391-405
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of different factors on momentum transfer in mechanically agitated multiphase systems
Autorzy:
Cudak, M.
Kiełbus-Rąpała, A.
Major-Godlewska, M.
Karcz, J.
Powiązania:
https://bibliotekanauki.pl/articles/185715.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multiphase system
agitated vessel
critical impeller speed
gas hold-up power
consumption
układ wielofazowy mieszalnika
krytyczne prędkości wirnika
konsumpcja
Opis:
A comparative analysis concerning the influence of different factors on momentum transfer in mechanically agitated systems was carried out on the basis of experimental results for solid-liquid, gas-liquid and gas-solid-liquid systems. The effects of the impeller - baffles system geometry, scale of the agitated vessel, type and number of impellers and their off-bottom clearance, as well as physical properties of the multiphase systems on the critical impeller speeds needed to produce suspension or dispersion, power consumption and gas hold-up were analysed and evaluated.
Źródło:
Chemical and Process Engineering; 2016, 37, 1; 41-53
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies