Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "concrete strength" wg kryterium: Temat


Tytuł:
Quasi-static failure criteria for concrete
Quasi-statyczne kryteria zniszczenia betonu
Autorzy:
Jankowiak, T.
Łodygowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/230145.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
beton
wytrzymałość betonu
parametr konstytutywny
identyfikacja
interpretacja energetyczna
kryterium zniszczenia
kryterium quasi-statyczne
concrete
concrete strength
constitutive parameters
identification
energetic interpretation
failure criterion
quasi-static criterion
Opis:
The behaviour of concrete under quasi-static loadings for uniaxial compression, tension and plane stress conditions is studied. The failure criteria of concrete are discussed as well as the methods of constitutive parameters identification are elaborated. The attention is focused on an energetic interpretation of selected failure criteria. The numerical example with concrete damage plasticity material model is shown.
W pracy prezentuje się zachowanie betonu przy obciążeniach quasi-statycznych przy jednoosiowym ściskaniu i rozciąganiu oraz w płaskim stanie naprężenia. Dyskutowane są kryteria zniszczenia betonu oraz metody identyfikacji parametrów konstytutywnych. Istotnym elementem jest również energetyczna interpretacja omawianych kryteriów. Zawarto przykład numeryczny wykorzystujący model materiału betonu plastycznego ze zniszczeniem, który dowodzi prawdziwości opisu konstytutywnego na podstawie wyników eksperymentalnych.
Źródło:
Archives of Civil Engineering; 2010, 56, 2; 123-154
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of hybrid fibers on toughness behavior of high strength flowing concrete
Autorzy:
Dawood, E. T.
Ramli, M.
Powiązania:
https://bibliotekanauki.pl/articles/231175.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
włókno hybrydowe
ciągliwość
beton wysokiej wytrzymałości
beton płynny
hybrid fiber
toughness
high strength concrete
flowing concrete
Opis:
This study investigates the use of steel fibers and hybrid composite with a total fibers content of 2% on the high strength flowing concrete and determines the density, compressive strength, static modulus of elasticity, flexural strength and toughness indices for the mixes. The results show that the inclusion of more than 0.5% of palm fibers in hybrid fibers mixes reduces the compressive strength. The hybrid fibers can be considered as a promising concept and the replacement of a portion of steel fibers with palm fibers can significantly reduce the density, enhance the flexural strength and toughness. The results also indicates that the use of hybrid fibers (1.5 steel fibers + 0.5% palm fibers) in specimens increases significantly the toughness indices and thus the use of hybrid fibers combinations in reinforced concrete would enhance their flexural toughness & rigidity and enhance their overall performances.
Źródło:
Archives of Civil Engineering; 2011, 57, 3; 249-260
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synergistic interaction of polypropylene fibres in latex modified high strength concrete
Autorzy:
Thirumurugan, S.
Sivakumar, A.
Powiązania:
https://bibliotekanauki.pl/articles/230938.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wytrzymałość na ściskanie
polimerobeton
włókna polipropylenowe
popiół lotny
impuls ultradźwiękowy
prędkość
beton wysokiej wytrzymałości
compressive strength
polymer concrete
polypropylene fibre
fly ash
ultrasonic pulse
velocity
high strength concrete
Opis:
Synthetic polymer latexes, such as styrene–butadiene rubber (SBR) latex addition in Portland cement has gained wider acceptance in many applications in the construction industry. Polymer-modified cementitious systems seals the pores and micro cracks developed during hardening of the cement matrix, by dispersing a film of polymer phase throughout the concrete. A comprehensive set of experimental test were conducted for studying the compressive properties of SBR latex polymer with crimped polypropylene fibres at relative volume fractions of 0.1 and 0.3%. The results indicated that the addition of polypropylene fibre has little effect on the reduction in the workability of concrete composite containing fly ash and SBR Latex. Increase in polypropylene fibres upto 0.3% Vf showed increase in compressive strength upto 57.5MPa. The SBR concrete without fibre showed an increase in strength upto 20 % compared to plain concrete. Test results also indicated that the compressive strength was increased in SBR fibre concrete by means of an ordinary dry curing process than wet curing because of their excellent water retention due to polymer film formation around the cement grains. On the contrary the compressive strength reduces for SBR fibre concretes under wet curing compared to dry curing.
Źródło:
Archives of Civil Engineering; 2013, 59, 3; 321-335
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimised mix design for normal strength and high performance concrete using particle packing method
Autorzy:
Gopinath, S.
Ramachandra-Murthy, A.
Ramya, D.
Iyer, N. R.
Powiązania:
https://bibliotekanauki.pl/articles/230735.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
beton zwykły
beton wysokowartościowy
metoda ACI
metoda BIS
upakowanie ziaren
upakowanie cząstek
projektowanie mieszanki
wytrzymałość na ściskanie
normal strength concrete
high performance concrete
ACI method
BIS method
particle packing
mix design
compressive strength
Opis:
This paper presents the details of optimized mix design for normal strength and high performance concrete using particle packing method. A critical review of mix design methods have been carried out for normal strength concrete using American Concrete Institute (ACI) and Bureau of Indian Standards (BIS) methods highlighting the similarities and differences towards attaining a particular design compressive strength. Mix design for M30 and M40 grades of concrete have been carried out using ACI, BIS and particle packing methods. Optimization of concrete mix has been carried out by means of particle packing method using EMMA software, which employs modified Anderson curve to adjust the main proportions. Compressive strength is evaluated for the adjusted proportions and it is observed that the mixes designed by particle packing method estimates compressive strength closer to design compressive strength. Further, particle packing method has been employed to optimize the ingredients of high performance concrete and experiments have been carried out to check the design adequacy of the desired concrete compressive strength.
Źródło:
Archives of Civil Engineering; 2011, 57, 4; 357-371
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of the research conditions on the accuracy of the designation of high performance concrete strength parameters
Wpływ warunków badania na parametry wytrzymałościowe betonów wysokowartościowych
Autorzy:
Wałach, D.
Powiązania:
https://bibliotekanauki.pl/articles/231367.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
beton wysokowartościowy
parametr wytrzymałościowy
warunki badania
high performance concrete
strength parameter
research condition
Opis:
The article presents research results of the strength parameters of HPC achieved in various research conditions. The research was carried out on substantially different samples, both as to the size as the slenderness ratio. Moreover, the assessment of the effect of speed of a load on strength parameters as well as other factors which in a significant way show the difference in the strength values was made. For comparison, the results were also applied to the relations known in ordinary concrete.
Postęp technologiczny spowodował znaczący rozwój produkcji betonu. Możliwość realizacji wielu obiektów, wymaga stosowania betonów o coraz bardziej specjalistycznych właściwościach a tym samym stosowanie mieszanek o coraz to wyższych wytrzymałościach. Odpowiedzią na te rosnące wymagania dzisiejszego budownictwa, może okazać się beton wysokowartościowy, który w ostatnim czasie znajduje coraz szersze zastosowanie. Określane parametry wytrzymałościowe betonów w istotny sposób zależą od warunków prowadzonych badań. Dotyczy to zarówno wielkości samych próbek badawczych jak i m.in. prędkości obciążania. Zagadnienia te w odniesieniu do betonów zwykłych są powszechnie znane, jednak w przypadku betonów wysokowartościowych, które ostatnio znajdują coraz powszechniejsze zastosowanie, uzyskuje się nieco odmienne wyniki badanych parametrów wytrzymałościowych niż w przypadku betonów zwykłych. Znajomość tych zagadnień może w istotny sposób wpływać m.in. na interpretację prowadzonych badań diagnostycznych elementów wykonanych z BWW. W artykule przedstawiono wyniki badań parametrów wytrzymałościowych BWW określonych przy różnych warunkach. Dla porównania uzyskane wyniki odniesiono do zależności znanych w betonach zwykłych.
Źródło:
Archives of Civil Engineering; 2016, 62, 4/I; 139-151
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The statistical analysis of relation between compressive and tensile/flexural strength of high performance concrete
Analiza statystyczna efektywności metod projektowych przewidywania wytrzymałości na rozciąganie i zginanie betonów wysokowartościowych
Autorzy:
Kępniak, M.
Woyciechowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/230497.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
beton wysokowartościowy
wytrzymałość na rozciąganie
wytrzymałość na zginanie
efektywność
metoda projektowania
high performance concrete
tensile strength
flexural strength
design method
efficiency
Opis:
This paper addresses the tensile and flexural strength of HPC (high performance concrete). The aim of the paper is to analyse the efficiency of models proposed in different codes. In particular, three design procedures from: the ACI 318 [1], Eurocode 2 [2] and the Model Code 2010 [3] are considered. The associations between design tensile strength of concrete obtained from these three codes and compressive strength are compared with experimental results of tensile strength and flexural strength by statistical tools. Experimental results of tensile strength were obtained in the splitting test. Based on this comparison, conclusions are drawn according to the fit between the design methods and the test data. The comparison shows that tensile strength and flexural strength of HPC depend on more influential factors and not only compressive strength.
Gdy naprężenie w betonowym elemencie konstrukcji przekracza granicę wytrzymałości na rozciąganie trwałość konstrukcji ulega zachwianiu. Jest to spowodowane ekspozycją zbrojenia na czynniki korozyjne. Betony wysokowartościowe (BWW) są coraz częściej wykorzystywane do wykonywania odpowiedzianych elementów obiektów budowlanych, gdzie trwałość jest jednym z kluczowych czynników. Szersze badania i analizy wydają się być uzasadnione, gdyż BWW różni się znacząco od betonu zwykłego. Celem artykułu jest analiza efektywności metod projektowych proponowanych w różnych normach. Związki pomiędzy wytrzymałością na rozciąganie a wytrzymałością na ściskanie proponowane przez trzy normy (Eurocode 2, ACI 318, Model Code 2010) zostały porównane z wynikami tych wytrzymałości uzyskanymi w sposób doświadczalny za pomocą narzędzi statystycznych. Wszystkie trzy z analizowanych norm uzależniają wynik wytrzymałości na rozciąganie oraz wytrzymałości na zginanie jedynie od klasy wytrzymałości na ściskanie. Eurocode 2 oraz Model Code 2010 rozróżniają zależność wytrzymałość na rozciąganie – wytrzymałość na ściskanie na zalecaną do stosowania dla klas betonu równą lub poniżej C50/60 oraz powyżej C50/60. Co sugerowałoby różny charakter zależności dla betonów wysokowartościowych.
Źródło:
Archives of Civil Engineering; 2016, 62, 4/II; 95-107
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Feasibility of making concrete using lignite coal bottom ash as fine aggregate
Wykorzystanie popiołu dennego ze spalania węgla brunatnego jako kruszywa drobnego do betonu
Autorzy:
Thandavamoorthy, T. S.
Powiązania:
https://bibliotekanauki.pl/articles/230561.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
beton
popiół denny
kruszywo drobne
wytrzymałość
trwałość
concrete
bottom ash
fine aggregate
strength
durability
Opis:
Concrete is generally produced using materials such as crushed stone and river sand to the extent of about 80-90% combined with cement and water. These materials are quarried from natural sources. Their depletion will cause strain on the environment. To prevent this, bottom ash produced at thermal power plants by burning of coal has been utilized in this investigation into making concrete. The experimental investigation presents the development of concrete containing lignite coal bottom ash as fine aggregate in various percentages of 25, 50, and 100. Compressive, split tensile, and flexural strength as part of mechanical properties; acid, sulphate attack, and sustainability under elevated temperature as part of durability properties, were determined. These properties were compared with that of normal concrete. It was concluded from this investigation that bottom ash to an extent of 25% can be substituted in place of river sand in the production of concrete.
Beton jest popularnym materiałem budowlanym przygotowywanym przy użyciu lokalnie dostępnych materiałów, takich jak tłuczeń kamienny, piasek i woda. Cement natomiast jest fabrycznie produkowanym składnikiem łączącym wszystkie te materiały. Materiały są dostosowane do wymagań, dobrze wymieszane i umieszczone w formie szalunkowej. Po około 18 do 24 godzin, usuwa się formę szalunkową, a beton pozostawia się do stwardnienia, jednocześnie pielęgnując go poprzez polewanie wodą przez około 28 dni lub aż do dnia badania. W miarę wydobywania tłucznia kamiennego oraz piasku z naturalnych źródeł, wykorzystywanie tych materiałów na dużą skalę nie tylko wyczerpuje źródła, ale również negatywnie wpływa na środowisko. Zbadanie alternatyw dla tych materiałów okazuje się być tym bardziej konieczne. Obecnie działalność człowieka generuje duże ilości odpadów przemysłowych, rolniczych, itp. Jednym z takich odpadów przemysłowych jest popiół denny otrzymywany z elektrowni cieplnych po spalaniu węgla w procesie wytwarzania energii elektrycznej. Struktura popiołu dennego uznaje się za podobną do piasku rzecznego, używanego jako drobne kruszywo do wytwarzaniu betonu. Charakterystyka popiołu dennego nie wszędzie wygląda tak samo, ponieważ właściwości węgla również zmieniają się w zależności od miejsca. Popiół denny z węgla brunatnego uzyskano z elektrociepłowni Neyveli Thermal Power Plant w Indiach i wykorzystano w badaniu eksperymentalnym, jako drobne kruszywo do przygotowania betonu. Popiół denny został użyty w celu zastąpienia piasku rzecznego według wskaźnika 25%, 50% i 100%. Określono właściwości fizyczne i chemiczne popiołu dennego.
Źródło:
Archives of Civil Engineering; 2015, 61, 3; 19-30
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigating the factor of safety for the design of columns using properties of steel rebarsmanufactured in Pakistan
Autorzy:
Abbas Zaidi, Safdar
Arsalan Saeed, Muhannad
Haider, Farhan
Powiązania:
https://bibliotekanauki.pl/articles/230463.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
współczynnik redukcji wytrzymałości
analiza wytrzymałościowa
obciążenie momentem
interakcja
słup żelbetowy
strength reduction factor
strength analysis
moment load
interaction
reinforced concrete column
Opis:
This paper includes the behaviour of RC column, using the steel strength data employed by Rafi et al. (2014). Eccentric short columns are studied for this purpose, both tension and compression controlled sections, are analysed considering the current design practice of Pakistan. Three cross sections were analysed using different steel percentages against load-moment interaction and the strength analyses. Concrete strength is also varied in this analysis. The load moment interaction diagrams were observed in major and minor axes and strength analysis is made for compression controlled and tension controlled sections. In this analysis it is observed that a section designed as a tension controlled is giving brittle failure at certain limit which should be avoided. Considering this scenario, several random cross sections are analysed, strength reduction factors for eccentric and pure axial columns are computed. Conclusions are made on behalf of this analysis for different types of column design.
Źródło:
Archives of Civil Engineering; 2020, 66, 3; 191-208
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Strengths of recycled concrete added with steel fiber
Autorzy:
Su, Q.
Powiązania:
https://bibliotekanauki.pl/articles/231177.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
beton
kruszywo z recyklingu
włókno stalowe
konsystencja
wytrzymałość na ściskanie
wytrzymałość na zginanie
recycled aggregate
concrete
steel fiber
slump
compressive strength
flexural strength
Opis:
The strength of recycled aggregate (RA) is low, which makes the performance of recycled aggregate concrete (RAC) poor, and the addition of fiber can make up for the shortcoming of RAC. In this paper, the mechanical properties of RAC which was added with steel fiber were studied. The specimens with RA content of 0%, 40%, 70% 100% and steel fiber content of 0%, 0.5% and 1% were prepared, and their mechanical properties were tested. The results showed that the slump reduced 73.75% after the addition of 100% RA and 37.5% after the addition of 1% steel fiber compared to R0S0; from the perspective of mechanical properties, the larger the content of steel fiber, the better the mechanical properties of the specimen; the improvement of the tensile strength was the most obvious after the addition of steel fiber. The experimental results show that steel fiber can improve the performance of RAC and make it perform better in practical application.
Źródło:
Archives of Civil Engineering; 2020, 66, 3; 693-703
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tests of residual shear transfer strength of concrete exposed to fire
Autorzy:
Shallal, M. A.
Al Musawi, A. M. K.
Powiązania:
https://bibliotekanauki.pl/articles/231496.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pożar
przeniesienie ścinania
wytrzymałość na ściskanie
żelbet
strzemię
fire
shear transfer
compressive strength
reinforced concrete
stirrup legs
Opis:
Reinforced concrete is one of the most widely used structural components about which much scientific research has been conducted; however, some of its characteristics still require further research. The main focus of this study is the effect of direct fire on the shear transfer strength of concrete. It was investigated under several parameters including concrete strength, number of stirrup legs (the steel area across the shear plane), and fire duration. The experimental program involved the testing of two sets (groups) of specimens (12 specimens each) with different concrete strengths. Each set contained specimens of two or four stirrup legs exposed to direct fire from one side (the fire was in an open area to simulate a real-life event) for a duration of one, two, and three hours. The results of the comparison showed the importance of using high-performance concrete (instead of increasing the number of stirrup legs) to resist shear stress for the purpose of safety. A significant reduction in shear strength occurred due to the deterioration of the concrete cover after three hours of direct fire exposure.
Źródło:
Archives of Civil Engineering; 2018, 64, 2; 187-199
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prediction of compressive strength in light-weight self-compacting concrete by ANFIS analytical model
Predykcja wytrzymałości na ściskanie lekkiego betonu samouszczelniającego wg modelu analitycznego ANFIS
Autorzy:
Vakhshouri, B.
Nejadi, S.
Powiązania:
https://bibliotekanauki.pl/articles/231455.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
właściwości mechaniczne
przewidywanie
ANFIS
analiza regresji
beton samozagęszczalny
beton lekki
wytrzymałość na ściskanie
moduł sprężystości
wytrzymałość na rozciąganie przy rozłupywaniu
mechanical properties
prediction
regression analysis
self-compacting concrete
light-weight concrete
compressive strength
elasticity modulus
splitting tensile strength
Opis:
Light-weight Self-Compacting Concrete (LWSCC) might be the answer to the increasing construction requirements of slenderer and more heavily reinforced structural elements. However there are limited studies to prove its ability in real construction projects. In conjunction with the traditional methods, artificial intelligent based modeling methods have been applied to simulate the non-linear and complex behavior of concrete in the recent years. Twenty one laboratory experimental investigations on the mechanical properties of LWSCC; published in recent 12 years have been analyzed in this study. The collected information is used to investigate the relationship between compressive strength, elasticity modulus and splitting tensile strength in LWSCC. Analytically proposed model in ANFIS is verified by multi factor linear regression analysis. Comparing the estimated results, ANFIS analysis gives more compatible results and is preferred to estimate the properties of LWSCC.
Lekki beton samouszczelniający (LWSCC) to połączenie betonu lekkiego (LWC) i samouszczelniającego (SCC) i posiada zarówno zalety, jak i wady obu typów betonu. Ze względu na złożony charakter i nieliniowe zachowanie LWSCC oraz dużą liczbę parametrów, które mają wpływ na wyniki analiz, tradycyjne metody mogą okazać się niewystarczające do określenia współzależności pomiędzy różnymi właściwościami LWSCC; jakkolwiek model ANFIS okazał się skuteczny, jeśli chodzi o określanie zależności pomiędzy parametrami w przypadku złożonych systemów technologicznych oraz materiałów. W opracowaniu wykorzystano znaczącą ilość danych eksperymentalnych, dotyczących tego nowego materiału budowlanego, w celu przeanalizowania zależności pomiędzy wytrzymałością na ściskanie (CS), wytrzymałością na rozciąganie (STS) oraz modułem sprężystości (EM). Dodatkowo, opracowano nowy model analityczny w ramach systemu rozmytego, który został też zweryfikowany przy pomocy zgromadzonych danych, jak również analizy regresji wieloczynnikowej. Zgromadzone dane umożliwiają także porównanie otrzymanych proporcji mieszanki LWSCC. Ponieważ w literaturze nie pojawiły się dotąd wskazówki w tym zakresie, porównanie takie może stać się doskonałym punktem wyjścia dla dalszych badań na temat właściwości LWSCC oraz składu mieszanki. Porównując wszystkie cechy charakterystyczne przy pomocy modelu ANFIS, opracowano model FIS przy zastosowaniu strukturę typu Sugento, funkcję przynależności w kształcie dzwonu oraz metodę optymalizacji hybrydowej.
Źródło:
Archives of Civil Engineering; 2015, 61, 2; 53-72
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bond strength of concrete-filled hollow section with modified fibrous foamed concrete
Autorzy:
Khairuddin, S. A. A.
Rahman, N. A.
Jamaluddin, N.
Jaini, Z. M.
Elamin, A.
Rum, R. H. M.
Powiązania:
https://bibliotekanauki.pl/articles/230151.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
siła wiązania
pusta sekcja wypełniona betonem
CFHS
beton modyfikowany
beton włóknisty
beton spieniony
popiół z łusek ryżowych
RHA
wytrzymałość
metoda push-out
bond strength
concrete filled hollow section
modified fibrous foamed concrete
rice husk ash
strength
push-out method
Opis:
The concrete-filled section of columns has been widely in construction used due to its structural elements. As a result, the usage of composite columns has recently increased all over the world. However, using foamed concrete alone does not result in much improvements in strength. Therefore, this paper examines the use of foamed concrete containing fibre to improve the strength of composite columns. Specifically, this study aims to determine the bond strength of concrete-filled hollow section (CFHS) with modified fibrous foamed concrete. Two types of fibre are used in this work, namely, steel fibre and polypropylene fibre, with rice husk ash (RHA) as a sand replacement to improve the compressive strength of foamed concrete. The CFHS with modified fibrous foamed concrete is tested by using the push-out method, and the results show that CFHS with steel fibre has a highest bond strength.
Źródło:
Archives of Civil Engineering; 2020, 66, 3; 97-108
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of micro synthetic fibers confinement on properties of lightweight foamed concrete
Autorzy:
Mydin, Md Azree Othuman
Powiązania:
https://bibliotekanauki.pl/articles/2174053.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pianobeton
kurczenie się
porowatość
absorpcja wody
wytrzymałość na ściskanie
wytrzymałość na zginanie
mikrowłókno syntetyczne
foamed concrete
shrinkage
porosity
water absorption
compressive strength
flexural strength
micro synthetic fiber
Opis:
In this investigation, the confinement effects of micro synthetic fibers on lightweight foamed concrete (LFC) were examined. The parameters evaluated were porosity, water absorption, shrinkage, compressive strength, flexural strength and tensile strength. Three densities were cast which were 600 kg/m3, 1100 kg/m3, and 1600 kg/m3. Besides, the number of layers (1 to 3 layers) of micro synthetic fibers was also being examined. Based on the result obtained, the porosity improved by 8.0% to 16.3%, 13.8% to 25.6%, and 9.3% to 24.5% for the LFC with densities of 600 kg/m3, 1100 kg/m3, and 1600 kg/m3 confined with 1 layer, 2 layers, and 3 layers of micro synthetic fibers, respectively. Besides, for the water absorption test, the enhancements were 6.9% to 15.6%, 20.0 to 27.1%, and 12.2 to 29.6% for the respective densities and number of layers of micro synthetic fibers employed, while the drying shrinkage improved by 48.5% to 76.8%, 57.4% to 72.1%, and 43.2 % to 68.2% for the respective densities and number of layers of micro synthetic fibers employed. For the strength properties, a confinement with 3 layers of micro synthetic fibers showed significant results, where enhancements of 153% (600 kg/m3), 97% (1100 kg/m3), and 102% (1600 kg/m3) were obtained for the compression strength; 372% (600 kg/m3), 258% (1100 kg/m3), and 332% (1600 kg/m3) for the bending strength; and 507% (600 kg/m3), 343% (1100 kg/m3), and 332% (1600 kg/m3) for the splitting tensile strength, respectively, compared to the control LFC.
Źródło:
Archives of Civil Engineering; 2022, 68, 3; 411--428
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hybrid effects of stirrup ratio and steel fibers on shear behaviour of self-compacting concrete
Hybrydowy wpływ stosunku strzemion i włókien stalowych na ścinanie betonu samozagęszczalnego
Autorzy:
Kannam, P.
Venkateswara Rao, S.
Pancharathi, R. K.
Powiązania:
https://bibliotekanauki.pl/articles/230257.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
beton samozagęszczalny
wytrzymałość na ścinanie
beton zbrojony
ścinanie spowodowane zginaniem
strzemiono
włókno stalowe
self compacting concrete
shear strength
reinforced concrete
flexural-shear failure
stirrup
steel fiber
Opis:
Shear cracking behaviour of fibrous self-compacting concrete of normal and high strength grade (M30 and M70) is presented here. Two stirrup diameters (6mm Φ and 8 mm Φ) with a constant steel fiber content of 38 kg/m3 (0.5% by volume of concrete) were selected for the present study. The size of the beam was fixed at 100x200x1200mm. The clear span of the beam 1100mm, was maintained throughout the study. A total of 16 shear-deficient beams were tested under three point loading. Two stirrup spacing (180 mm and 360 mm) are used for the shear span-to-depth ratio (a/d = 2). Investigation indicates that initial cracking load and ultimate load increased as the area of shear reinforcement increased by increasing the diameter of stirrup. It was also noted that the failure mode was modified from brittle shear failure to flexural-shear failure in the presence of fibers. The mechanical behaviour of SFRSCC was improved due to the combined effect of stirrups and steel fibers. The stiffness, toughness, and deflection of the beams increased when compared to SCC beams without fibers. The experimental results were compared with existing models available in literature, and the correlation is satisfactory.
Spośród wszystkich rodzajów uszkodzeń betonu, ścinanie jest nagłe i kruche i pojawia się gwałtownie, bez ostrzeżenia. Aby uniknąć tego rodzaju problemów z betonem, belki są tradycyjnie wzmacniane za pomocą strzemion, w bliższej odległości od konstrukcji. Ograniczone rozmieszczenie prętów zbrojeniowych i strzemion na elementach wykonanych z betonu zbrojonego (RC), takich jak słupy, belki i płyty, utrudnia zagęszczanie betonu w każdym miejscu w szalunku za pomocą wibratorów mechanicznych. Pustki i makropory wewnątrz betonu powstają w wyniku nieodpowiednich drgań, a zatem zagęszczenie może wpływać na wytrzymałość mechaniczną i trwałość betonu, a także stać się możliwą przyczyną pogorszenia jego jakości. Beton konwencjonalny stosowany w budownictwie i inżynierii lądowej wymaga zagęszczania w celu uzyskania wytrzymałości, trwałości i konsystencji. Ta klasyczna metoda zagęszczania i drgań powoduje zakłócenia i dodatkowe koszty dla projektów, a ponadto stanowi poważne zagrożenie dla zdrowia na i w okolicach placu budowy. Beton samozagęszczalny (SCC), jak sama nazwa wskazuje, nie wymaga zewnętrznego wysiłku przy zagęszczaniu. Jest to dobrze przemyślane rozwiązanie, mające na celu pozbycie się powyższego problemu. Ze względu na wyżej opisaną właściwość, nie potrzeba drgań, a więc nie powstają również zanieczyszczenia hałasem, zmniejszają się koszty robocizny i beton może być zagęszczany w każdym miejscu szalunku, bez jakiejkolwiek znaczącej segregacji, przeważnie w zatkanych wzmocnieniach. W niniejszej pracy przedstawiono charakterystykę pękania przy ścinaniu włóknistego betonu samozagęszczalnego o normalnym i wysokim stopniu wytrzymałości (M30 i M70). W niniejszej pracy zastosowano dwie średnice strzemion (6 mm i 8 mm) o stałej zawartości włókien stalowych wynoszącej 38 kg/m3 (0.5% objętości betonu). Rozmiar belki został ustalony na 100 x 200 x 1200 mm. Przez cały okres trwania badania utrzymywano rozstaw belek wynoszący 1100 mm. Łącznie zbadano 16 belek z niedostatnim ścinaniem przy obciążeniu trzypunktowym. Dwa rozstawy strzemion (180 mm i 360 mm) są stosowane dla stosunku ścinania do głębokości (a/d = 2). Badanie wykazało, że początkowe obciążenie przy pękaniu oraz końcowe obciążenie wzrosły wraz ze wzrostem średnicy strzemienia. Zauwaono również, ze tryb awaryjny zmienił sie z kruchego ścinania na scinanie spowodowane zginaniem przy obecności włókien. Zachowanie mechaniczne SFRSCC uległo poprawie w wyniku połączonego efektu działania strzemion i włókien stalowych. Sztywność, wytrzymałość i ugięcie belek wzrosły w porównaniu do belek SCC bez włókien. Wyniki eksperymentalne zostały porównane z istniejącymi modelami dostępnymi w literaturze, a korelacja okazała się być zadowalająca.
Źródło:
Archives of Civil Engineering; 2018, 64, 1; 145-169
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of the bending strenght of a steel plate-concrete composite beams defined experimentally, theoretically and numerically
Ocena nośności na zginanie belek zespolonych typu blacha stalowa-beton
Autorzy:
Kisała, D.
Furtak, K.
Powiązania:
https://bibliotekanauki.pl/articles/231443.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
belka stalowo-betonowa
belka zespolona
wytrzymałość na zginanie
badanie eksperymentalne
steel-concrete beam
composite beam
bending strength
experimental test
Opis:
Badania konstrukcji zespolonych typu blacha stalowa-beton, nie mają długiej tradycji. Są one z jednej strony modyfikacją klasycznych konstrukcji zespolonych typu stal-beton, a z drugiej kontynuatorem konstrukcji Möllera, stosowanych już pod koniec XIX wieku. Pewne podobieństwo występuje, między analizowanymi konstrukcjami a elementami żelbetowymi wzmacnianymi zespolonymi z nimi blachami stalowymi lub taśmami kompozytowymi. Rozwiązania te stosuje się przy wzmacnianiu belek żelbetowych. Krótki okres stosowania belek zespolonych typu blacha stalowa-beton sprawia, że wiele problemów - nawet natury podstawowej - jest jeszcze do rozwiązania. Dotyczy to także nośności przy obciążeniach doraźnych, a także ugięć i zarysowania oraz wpływu skurczu i pełzania betonu. W obliczeniach praktycznych nie uwzględnia się parametru czasu (obciążenia długotrwałe), a także odkształceń skurczowych betonu i jego pełzania. Celem pracy jest podanie rozwiązania teoretycznego, dotyczącego nośności na zginanie elementów zespolonych typu blacha stalowa-beton oraz przeprowadzenie analizy wpływu wybranych parametrów na tę nośność. Zakres pracy obejmuje podanie stosownych wzorów z uwzględnieniem specyfiki analizowanych belek. W analizie podanych rozwiązań wzięto pod uwagę geometrię przekroju poprzecznego belek oraz cechy mechaniczne materiałów składowych.
The aim of the paper was to assess the bending strength of steel plate - concrete composite members, based on an experimental study performed by the authors together with theoretical and numerical analyses. The values of the mechanical parameters of the materials the beams were made from were adopted on the basis of the tests results. The proposed solutions have been verified by experiment. For this purpose the results of tests performed by the authors and other researchers have been used. The former ones are original, and the way of their presentation makes them applicable by other researchers. Following the results it can be stated that with respect to bending strengths from the experimental study the results obtained from the theoretical analysis are underestimated 6,6 % on average. The results based on the numerical analysis, on the other hand, are overestimated by - 7,5 % on average. The results of the theoretical and numerical analyses indicate that the interface slip between the steel plate and concrete part affect the bending strength of steel plate-concrete composite beams only slightly (about 2% on average).
Źródło:
Archives of Civil Engineering; 2020, 66, 3; 623-641
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies