Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "air heat pump" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Parametric study of fluid flow and heat transfer over louvered fins of air heat pump evaporator
Autorzy:
Muszyński, T.
Kozieł, S. M.
Powiązania:
https://bibliotekanauki.pl/articles/240658.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat exchangers
heat transfer intensification
CFD
convection
air source heat pump
wymienniki ciepła
intensyfikacja wymiany ciepła
konwekcja
powietrzne pompy ciepła
Opis:
Two-dimensional numerical investigations of the fluid flow and heat transfer have been carried out for the laminar flow of the louvered fin-plate heat exchanger, designed to work as an air-source heat pump evaporator. The transferred heat and the pressure drop predicted by simulation have been compared with the corresponding experimental data taken from the literature. Two dimensional analyses of the louvered fins with varying geometry have been conducted. Simulations have been performed for different geometries with varying louver pitch, louver angle and different louver blade number. Constant inlet air temperature and varying velocity ranging from 2 to 8 m/s was assumed in the numerical experiments. The air-side performance is evaluated by calculating the temperature and the pressure drop ratio. Efficiency curves are obtained that can be used to select optimum louver geometry for the selected inlet parameters. A total of 363 different cases of various fin geometry for 7 different air velocities were investigated. The maximum heat transfer improvement interpreted in terms of the maximum efficiency has been obtained for the louver angle of 16° and the louver pitch of 1.35 mm. The presented results indicate that varying louver geometry might be a convenient way of enhancing performance of heat exchangers.
Źródło:
Archives of Thermodynamics; 2016, 37, 3; 45-62
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research to estimate energy efficiency of a ventilation and air conditioning heat pump system inside a production premise with ventilation air recovery
Autorzy:
Bezrodny, Myhailo Kostiantynovych
Misiura, Tymofii Oleksiyovych
Powiązania:
https://bibliotekanauki.pl/articles/1955060.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
air conditioning
heat pump system
refrigeration efficiency
recuperation
Opis:
The research provides a thermodynamic analysis of the theoretical model of a ventilation and air conditioning heat pump system with the ventilation air cold energy recovery depending on outside air parameters, the recovery efficiency and characteristics of a premise. A confectionery production workshop was taken as a prototype where technological conditions (temperature and humidity) must be maintained during the warm season. Calculations using the method of successive approximations to estimate air parameters at system’s nodal points were conducted. It allowed to determine theoretical refrigeration efficiency of the studied system and proved advantages of heat recuperation for smaller energy consumption. The model can be applied for design of heating, ventilation, and air conditioning units which work as a heat pump. The studied system has the highest energy efficiency in the area of relatively low environment temperatures and relative humidity which is suitable for countries with temperate continental climates characterized by low relative humidity.
Źródło:
Archives of Thermodynamics; 2021, 42, 4; 69-86
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency of heat pump systems of air conditioning for removing excessive moisture
Autorzy:
Bezrodny, Mikhail
Prytula, Natalia
Tsvietkova, Maria
Powiązania:
https://bibliotekanauki.pl/articles/240821.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat pump
air conditioning systems
comfortable conditions
production facilities with excess moisture
pompa grzejna
systemy klimatyzacji
wilgoć
Opis:
The conditions of efficient use of heat pumps in air conditioning systems are considered in order to ensure the established temperature and relative humidity of air in premises with the removal of excess moisture in the warm or hot periods of the year. For this purpose, a thermodynamic analysis of heat pump air conditioning schemes with exhaust air recirculation through a condenser and through a heat pump evaporator has been carried out. To determine the potential capabilities of such schemes to maintain comfortable conditions in the production room, a numerical analysis of their operating parameters, depending on the temperature and relative humidity of external atmospheric air, was performed. It has been shown that recirculation of exhaust air through the heat pump evaporator allows to maintain the given conditions in the room in a wider range of parameters of external atmospheric air. In addition, it has been shown that such a scheme requires less specific energy consumption for the operation of heat pump, which means that it is more efficient.
Źródło:
Archives of Thermodynamics; 2019, 40, 2; 151-165
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies