Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Wastewater Treatment" wg kryterium: Temat


Tytuł:
Azo dye wastewater treatment in a novel process of biofilm coupled with electrolysis
Autorzy:
Zou, Haiming
Chu, Lin
Wang, Yang
Powiązania:
https://bibliotekanauki.pl/articles/204706.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
azo dye wastewater treatment
color removal
biofilm
electrolysis
bioelectrochemical system
Opis:
Azo dye wastewater treatment is urgent necessary nowadays. Electrochemical technologies commonly enable more efficient degradation of recalcitrant organic contaminants than biological methods, but those rely greatly on the energy consumption. A novel process of biofilm coupled with electrolysis, i.e., bioelectrochemical system (BES), for methyl orange (MO) dye wastewater treatment was proposed and optimization of main influence factors was performed in this study. The results showed that BES had a positive effect on enhancement of color removal of MO wastewater and 81.9% of color removal efficiency was achieved at the optimum process parameters: applied voltage of 2.0 V, initial MO concentration of 20 mg/L, glucose loads of 0.5 g/L and pH of 8.0 when the hydraulic retention time (HRT) was maintained at 3 d, displaying an excellent color removal performance. Importantly, a wide range of effective pH, ranging from 6 to 9, was found, thus greatly favoring the practical application of BES described here. The absence of a peak at 463 nm showed that the azo bond of MO was almost completely cleaved after degradation in BES. From these results, the proposed method of biodegradation combined with electrochemical technique can be an effective technology for dye wastewater treatment and may hopefully be also applied for treatment of other recalcitrant compounds in water and wastewater
Źródło:
Archives of Environmental Protection; 2019, 45, 3; 38-43
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Correlations between organic pollution indicators in municipal wastewater
Korelacje pomiędzy wskaźnikami zanieczyszczeń organicznych w ściekach komunalnych
Autorzy:
Siwiec, T.
Reczek, L.
Michel, M. M.
Gut, B.
Hawer-Strojek, P.
Czajkowska, J.
Jóźwiakowski, K.
Gajewska, M.
Bugajski, P.
Powiązania:
https://bibliotekanauki.pl/articles/205468.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
BOD5
CODCr
TOC
CODMn
wastewater
municipal wastewater treatment plant
BZT5
ścieki
miejska oczyszczalnia ścieków
Opis:
The paper presents the results of a study of parameters used for determining the amount of organic pollutants in wastewater flowing into a collective wastewater treatment plant with a population equivalent of about 120 000 PE. The plant constituted part of a sewage system. Assays were performed for biochemical oxygen demand (BOD5), chemical oxygen demand (CODCr), permanganete index (CODMn) and total organic carbon (TOC). In addition, the pH of wastewater and its alkalinity were determined. Sampling of incoming wastewater and measurement of physicochemical parameters were performed once a week, in the spring. A total of 44 samples of wastewater were collected. The correlations between the individual parameters and the correlations between the ratios of these parameters were determined. It was found that it was possible to estimate, with sufficient accuracy, the values of selected parameters for determining the concentrations of organic compounds in municipal wastewater, knowing the values of other parameters in this group. Moreover, it was shown that, knowing the relationship between the analyzed parameters, one can find multiple regression equations for a given type of wastewater, which allow one to calculate the remaining relationships with a good fi t, i.e. a determination factor R2 greater than 0.6.
W pracy przedstawiono wyniki badań parametrów wykorzystywanych do oznaczania ilości zanieczyszczeń organicznych w ściekach wpływających do zbiorczej oczyszczalni ścieków o równoważnej liczbie ludności około 120 000 mieszkańców. Zakład stanowi część systemu kanalizacyjnego. Testy przeprowadzono dla biochemicznego zapotrzebowania na tlen (BZT5), chemicznego zapotrzebowania na tlen (CODCr), utlenialności (CODMn) i ogólnego węgla organicznego (TOC). Ponadto określono wartość pH ścieków i ich zasadowość. Pobieranie próbek dopływających ścieków i pomiar parametrów fizykochemicznych przeprowadzano raz w tygodniu, na wiosnę. Zebrano łącznie 44 próbki ścieków. Określono korelacje między poszczególnymi parametrami i korelacje między stosunkami tych parametrów. Stwierdzono, że możliwe było oszacowanie, z wystarczającą dokładnością, wartości wybranych parametrów do oznaczania stężeń związków organicznych w ściekach komunalnych, znając wartości innych parametrów w tej grupie. Ponadto wykazano, że znając zależność między analizowanymi parametrami, można znaleźć równania regresji wielokrotnej dla danego typu ścieków, które pozwalają obliczyć pozostałe zależności przy dobrym dopasowaniu, o współczynniku determinacji R2 większym niż 0,6.
Źródło:
Archives of Environmental Protection; 2018, 44, 4; 50-57
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Treatment of wastewater to meet the requirements for cooling water systems in jordan’s nuclear plants
Autorzy:
Al-Rawajfeh, A.E.
Araj, K.
Powiązania:
https://bibliotekanauki.pl/articles/184961.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cooling water
nuclear plants
wastewater treatment
scale deposition
schładzanie wody
elektrownia jądrowa
oczyszczanie ścieków
Opis:
Scaling and corrosion associated with the use of natural hard water in cooling towers during recirculation pose great problems from both economical and technical points of view, such as decreased system efficiency and increased frequency of chemical cleaning. Treated municipal wastewater (MWW) is a promising alternative to freshwater as power plant cooling system makeup water, especially in arid regions. In this work, hybrid systems of salt precipitation (SP), nanofiltration (NF) and reverse osmosis (RO) were investigated, as potential pretreatment processes for wastewater reuse as cooling water in the planned Jordan nuclear power plants. The As-Samra wastewater was used to calculate the potential of carbonate and sulfate scale formation. The results were compared to scale potentials from Palo Verde wastewater. Four cases were investigated; SP, NF, SP-RO and NF-RO. The SP pretreatment cases showed the highest monovalent to divalent ratio because of a high removal of Ca and Mg and addition of Na from the chemicals of the SP step. The NF pretreatment cases, showed the lowest calcium sulfate scale potential and this potential decreases with the % pretreatment. The scale amount increases very slightly with concentration times when the SP and NF product is desalinated by RO step.
Źródło:
Chemical and Process Engineering; 2013, 34, 2; 253-267
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Antibiotics in WWTP discharge into the Chaobai River, Beijing
Autorzy:
Zhang, C.
Wang, L.
Gao, X.
He, X.
Powiązania:
https://bibliotekanauki.pl/articles/204951.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
antibiotics
PPCPs
pharmaceuticals and personal care products
WWTP
wastewater treatment plant
BAF
biological aerated filter
advanced treatment
Opis:
22 representative antibiotics, including 8 quinolones (QNs), 9 sulfonamides (SAs), and 5 macrolides (MCs) were selected to investigate their occurrence and removal efficiencies in a Wastewater Treatment Plant (WWTP) and their distribution in the receiving water of the Chaobai River in Beijing, China. Water quality monitoring was performed in an integrated way at different selected points in the WWTP to explore the potential mechanism of antibiotics removal during wastewater treatment. Water quality of the Chaobai River wa s also analyzed to examine environmental distribution in a river ecosystem. The results showed that within all the 22 compounds examined, 10 antibiotics were quantifi ed in wastewater influent, 10 in effluent, and 7 in river. Sulfadiazine (SDZ, 396 ng/L) and Sulfamethazine (SMZ, 382 ng/L) were the dominating antibiotics in the influent. Both the conventional treatment and advanced Biological Aerated Filter (BAF) system was important for the removal of antibiotics from the wastewater. And the concentrations of selected antibiotics were ranged from 0–41.8 ng/L in the effluent-receiving river. Despite the fact that the concentrations were reduced more than 50% compared to effluent concentrations, WWTP discharge was still regarded as a dominant point-source input of antibiotics into the Chaobai River.
Źródło:
Archives of Environmental Protection; 2016, 42, 4; 48-57
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Turbidity measurements as a tool of monitoring and control of the SBR effluent at the small wastewater treatment plant : preliminary study
Wstępne badania nad zastosowaniem pomiaru mętności ścieków oczyszczonych jako elementu kontroli i sterowania pracą oczyszczalni o działaniu cyklicznym
Autorzy:
Mucha, Z.
Kułakowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/205223.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
effluent quality
wastewater turbidity
SBR reactor
TSS
COD
wastewater treatment plant control
jakość ścieków
mętność ścieków
reaktor SBR
kontrola jakości ścieków
Opis:
The paper presents preliminary results of investigations on a relationship between turbidity and other quality parameters in the SBR plant effluent. The laboratory tests demonstrated a high correlation between an effluent turbidity and a total suspended solids (TSS) concentration as well as between TSS and COD. Such a relationship would help to continuously monitor and control quality of a wastewater discharge using turbidity measurement.
W artykule przedstawiono wstępne wyniki badań zależności pomiędzy mętnością a innymi wskaźnikami zanieczyszczeń w ściekach oczyszczonych odpływających z oczyszczalni z reaktorami osadu czynnego o działaniu cyklicznym typu SBR. Wykonane badania potwierdzają wysoką korelację zarówno pomiędzy wartością mętności a stężeniem zawiesiny jak i pomiędzy wartością mętności a ChZT w ściekach oczyszczonych co może pozwolić na ciągłą kontrolę i sterowanie jakością ścieków odpływających do odbiornika przy zastosowaniu pomiaru mętności.
Źródło:
Archives of Environmental Protection; 2016, 42, 3; 33-36
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automotive fleet repair facility wastewater treatment using air/ZVI and air/ZVI/H2O2 processes
Oczyszczanie ścieków z zakładów naprawczych floty samochodowej z wykorzystaniem procesów powietrze/ZVI i powietrze/ZVI/H2O2
Autorzy:
Bogacki, J. P.
Al-Hazmi, H.
Powiązania:
https://bibliotekanauki.pl/articles/205311.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wastewater treatment
zero-valent iron
advanced oxidation processes
AOP
ZVI
oczyszczanie ścieków
żelazo metaliczne
zaawansowane procesy utleniania
Opis:
Advanced automotive fleet repair facility wastewater treatment was investigated with Zero-Valent Iron/Hydrogen Peroxide (Air/ZVI/H2O2) process for different process parameters: ZVI and H2O2 doses, time, pH. The highest Chemical Oxygen Demand (COD) removal efficiency, 76%, was achieved for ZVI/H2O2 doses 4000/1900 mg/L, 120 min process time, pH 3.0. COD decreased from 933 to 227 mg/L. In optimal process conditions odor and color were also completely removed. COD removal efficiency was increasing with ZVI dose. Change pH value below and over 3.0 causes a rapid decrease in the treatment effectiveness. The Air/ZVI/H2O2 process kinetics can be described as d[COD]/dt = -a [COD]tm, where ‘t’ corresponds with time and ‘a’ and ‘m’ are constants that depend on the initial reagent concentrations. H2O2 influence on process effect was assessed. COD removal could be up to 40% (560 mg/L) for Air/ZVI process. The FeCl3 coagulation effect was also evaluated. The best coagulation results were obtained for 700 mg/L Fe3+ dose, that was slightly higher than dissolved Fe used in ZVI/H2O2 process. COD was decreased to 509 mg/L.
Ścieki z zakładu naprawczego floty samochodowej poddano oczyszczaniu z wykorzystaniem żelaza metalicznego i nadtlenku wodoru (Air/ZVI/H2O2). Badano wpływ dawki żelaza i nadtlenku wodoru, czasu i pH na efektywność procesu. Największy stopień usunięcia ChZT, 76%, uzyskano dla dawek ZVI/H2O2 4000/1900 mg/L, czasu 120 min i pH 3.0. ChZT zmniejszono z 933 do 227 mg/L. Dodatkowo uzyskano całkowite usunięcie barwy i zapachu. Skuteczność usunięcia ChZT rosła wraz ze wzrostem zastosowanej dawki ZVI. Zmiana pH na inne niż 3, powoduje gwałtowne zmniejszenie efektywności procesu. Kinetyka procesu może zostać opisana z wykorzystaniem równania d[COD]/dt = -a [COD]tm, gdzie ‘t’ oznacza czas a ‘a’ i ‘m’ są stałymi zależnymi od początkowego stężenia reagentów. Badano także wpływ H2O2 na efektywność procesu. Skuteczność usunięcia ChZT wynosi 40% (560 mg/L) w przypadku zastosowania ZVI bez dodatku H2O2. Określono także skuteczność koagulacji z wykorzystaniem FeCl3. Najlepsze rezultaty uzyskano dla dawki Fe3+ 700 mg/L, zmniejszając ChZT do 509 mg/L.
Źródło:
Archives of Environmental Protection; 2017, 43, 3; 24-31
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The small Wastewater Treatment Plants – Hydrobotanical Systems in Environmental Protection
Małe oczyszczalnie ścieków - systemy hydrobotaniczne w ochronie środowiska
Autorzy:
Pawęska, K.
Kuczewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/204905.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
mała oczyszczalnia ścieków
ochrona środowiska
system hydrobotaniczny
constructed wetlands
stężenie zanieczyszczeń
hydrobotanical wastewater treatment plants
concentration of pollutants
Opis:
The paper presents results of research concerning operating of fi ve small wastewater treatment plants working in two different technologies: hydrobotanical wastewater treatment plant and constructed wetland. Each object was designed for the treatment of domestic sewage after preliminary mechanical treatment in a septic tank. Hydrobotanical wastewater treatment plants and one of constructed wetland beds were built for treating sewage produced in educational institutions and resort. In the article attention is paid to possibility of exceeding the maximum allowable concentration of pollutants for three main indicators of pollution: BOD5, COD, and total suspension. The reduction of these indices is required by the Regulation of the Minister of Environment [14] for wastewater treatment plants with PE < 2000. In addition, the paper presents the effects of wastewater treatment to reduce biogens. The best quality of outfl ow was reached by outfl ows from constructed wetland treatment plants. None of the observed objects fulfi lled the requirements in terms of allowable concentrations for total suspension. The most effective were objects operating in technology of "constructed wetland".
W pracy przedstawiono wyniki badań dotyczące pracy małych pięciu oczyszczalni ścieków pracujących w dwóch technologiach: oczyszczalnie hydrobotaniczne oraz constructed wetland. Każdy z obiektów przeznaczony był do oczyszczania ścieków bytowych po wstępnym mechanicznym oczyszczaniu w osadniku gnilnym. Oczyszczalnie hydrobotaniczne oraz jeden z obiektów constructed wetland wybudowano w celu oczyszczania ścieków pochodzących z placówek oświatowych, pozostałe złoże gruntowo-trzcinowe oczyszczało ścieki z ośrodka wypoczynkowego. W artykule zwrócono szczególną uwagę na możliwość przekroczenia maksymalnego dopuszczalnego stężenia zanieczyszczeń wg obowiązujących w Polsce przepisów, dla trzech podstawowych wskaźników zanieczyszczeń: BZT5, ChZT oraz zawiesiny ogólnej. Redukcja tych indeksów wymagana jest Rozporządzeniem MŚ [14] dla oczyszczalni o RLM < 2000. Ponadto w pracy przedstawiono również efekty oczyszczania na rzecz redukcji biogenów. Najlepszą jakością charakteryzowały się odpływy z oczyszczalni pracujących w technologii constructed wetland. Natomiast żaden z obserwowanych obiektów nie spełniał wymogów pod względem dopuszczalnych stężeń dla zawiesiny ogólnej. Najskuteczniej oczyszczały ścieki obiekty pracujące w technologii "constructed wetland".
Źródło:
Archives of Environmental Protection; 2013, 39, 1; 3-16
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Toxicity of Aluminium Salts to Lecane Inermis Rotifers : Are Chemical and Biological Methods Used to Overcome Activated Sludge Bulking Mutually Exclusive?
Toksyczność soli glinu dla wrotków Lecane inermis : czy chemiczne i biologiczne metody zwalczania puchnięcia osadu czynnego wykluczają się wzajemnie?
Autorzy:
Klimek, B.
Fiałkowska, E.
Fyda, J.
Kocerba-Soroka, W.
Pajdak-Stós, A.
Sobczyk, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/205077.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
toxicity of Al-salts
EC50
rotifers
wastewater treatment
combined stressors
toksyczność soli glinu
wrotki
oczyszczanie ścieków
łączenie stresorów
Opis:
The aim of this study was to assess the effects of two flocculants that are often used to overcome activated sludge bulking problems - aluminium chloride, AlCl3, and aluminium sulphate, Al2(SO4)3 - on Lecaneinermis (Rotifera, Monogononta) at three different temperatures: 8, 15 and 20°C. The mean EC50 value (effective concentration, mg dm-3) calculated for the 24 h mortality test was 0.012 mg Al3+dm-3. Next, the effects of low concentrations of the Al-salts on the population development from single individuals (parthenogenetic females) were tested in a 21-day experiment. At concentrations as low as EC4.8 and EC0.48, both Al-salts affected rotifer population negatively. However, temperature was the most pronounced factor that modified the toxicity of the Al-salts to the rotifers. On the 12th day of the experiment, there were significant interactions between temperature and the Al-salts, indicating that the chemicals were more toxic to the rotifers at 20°C than at lower temperatures. The weaker rotifers sensitivity to Al-salts (especially to AlCl3) in temperatures below 15°C, when the biggest problems associated with sludge bulking occurs,may means use both rotifers and chemicals reasonable and effective.
Sole glinu są powszechnie stosowanym fl okulantem, służącym zwalczaniu puchnięcia osadu czynnego w biologicznych oczyszczalniach ścieków. Nowa idea biologicznego zwalczania tego niekorzystnego dla prawidłowej pracy oczyszczalni zjawiska polega na zastosowaniu wrotków z gatunku z Lecaneinermis. Wrotki te naturalnie występują w osadzie czynnym i są w stanie zjadać bakterie nitkowate, jak Microthrixparvicella, sprawiające najwięcej problemów w eksploatacji oczyszczalni podczas miesięcy zimowych. Celem badań było porównanie toksyczności chlorku glinu AlCl3 oraz siarczanu glinu Al2(SO4)3 dla wrotków Lecaneinermis w trzech temperaturach: 8, 15 and 20°C. Średnią wartość EC50 (stężenie powodujące 50% efekt, mg dm-3) dla śmiertelności wrotków na podstawie 24-godzinnego testu ustalono na poziomie 0.012 mg Al3+ dm-3. Następnie, badano wpływ niskich stężeń soli glinu na tempo wzrostu populacji z pojedynczego osobnika (partenogenetyczna samica) w 21-dniowym eksperymencie. Ustalono, że stężenia na poziomie odpowiadającym EC4.8, a nawet EC0.48 wpływają negatywnie na tempo wzrostu populacji. Temperatura silnie wpływała na toksyczność glinu. W 12-tym dniu eksperymentu stwierdzono, że zachodzi istotna interakcja pomiędzy toksycznością glinu i temperaturą, wskazująca, że w 20°C glin jest bardziej toksyczny dla wrotków niż w niższych badanych temperaturach. Mniejsza wrażliwość wrotków na glin w temperaturze poniżej 15°C może oznaczać, że łączenie tych dwóch metod zwalczania puchnięcia osadu czynnego w miesiącach zimowych może być racjonalnym i efektywnym rozwiązaniem.
Źródło:
Archives of Environmental Protection; 2013, 39, 3; 127-138
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of multi-criteria analysis for selection of technology for a household WWTP compatible with sustainable development
Zastosowanie analizy wielokryterialnej do wyboru rozwiązania technologicznego przydomowej oczyszczalni ścieków zgodnego z ideą zrównoważonego rozwoju
Autorzy:
Jóźwiakowski, K.
Mucha, Z.
Generowicz, A.
Baran, S.
Bielińska, J.
Wójcik, W.
Powiązania:
https://bibliotekanauki.pl/articles/205034.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
household
wastewater treatment
multi-criteria analysis
sustainable development
rural areas
gospodarstwo domowe
oczyszczanie ścieków
analiza wielokryterialna
rozwój zrównoważony
obszary wiejskie
Opis:
This paper presents the use of multi-criteria analysis as a tool that helps choosing an adequate technology for a household wastewater treatment plant. In the process of selection the criteria of sustainable development were taken into account. Five municipal mechanical-biological treatment plants were chosen for the comparative multi-criteria analysis. Different treatment technologies, such as sand filter, activated sludge, trickling filter, a hybrid system - activated sludge/trickling filter and a hybrid constructed wetland system VF-HF type (vertical and horizontal flow) were taken into account. The plants’ capacities were 1 m3∙d-1 (PE=8) and they all meet the environmental regulations. Additionally, a solution with a drainage system was included into the analysis. On the basis of multi-criteria analysis it was found that the preferred wastewater treatment technologies, consistent with the principles of sustainable development, were a sand filter and a hybrid constructed wetland type VF-HF. A drainage system was chosen as the best solution due to the economic criteria, however, taking into consideration the primary (ecological) criterion, employment of such systems on a larger scale disagree with the principles of sustainable development. It was found that activated sludge is the least favourable technology. The analysis showed that this technology is not compatible with the principles of sustainable development, due to a lack of proper technological stability and low reliability.
W pracy przedstawiono sposób wykorzystania analizy wielokryterialnej jako narzędzia pomocniczego do wyboru właściwego rozwiązania technologicznego przydomowej oczyszczalni ścieków. Przy wyborze uwzględniano kryteria zgodne z zasadami zrównoważonego rozwoju. Do porównawczej analizy wielokryterialnej wybrano 5 wariantów przydomowych, mechaniczno-biologicznych oczyszczalni ścieków. Porównywano systemy z filtrem piaskowym, z osadem czynnym, ze złożem biologicznym zraszanym, system hybrydowy - osad czynny ze złożem biologicznym oraz hybrydowy system hydrofi towy typu VF-HF (z pionowym i poziomym przepływem ścieków). Analizowano rozwiązania o przepustowości 1 m3∙d-1 (Równoważna Liczba Mieszkańców - RLM = 8), spełniające wymagania przepisów ochrony środowiska. Dodatkowo także rozwiązanie z zastosowaniem drenażu rozsączającego. Na podstawie analizy wielokryterialnej stwierdzono, że najbardziej korzystnymi rozwiązaniami technologicznymi, zgodnymi z zasadami zrównoważonego rozwoju, są systemy z filtrem piaskowym i hybrydowe systemy hydrofi towe typu VF-HF. Przy znacznej przewadze kryteriów ekonomicznych, jako najbardziej korzystne rozwiązanie wybrany został system z drenażem rozsączający, jednak biorąc pod uwagę kryterium nadrzędne (ekologiczne), aby zachować zasadę zrównoważonego rozwoju, należałoby wykluczyć możliwość stosowania tych rozwiązań na większą skalę. Stwierdzono, że najbardziej niekorzystnym jest rozwiązanie technologiczne z wykorzystaniem osadu czynnego. Wykonana analiza wykazała, że stosowanie tej technologii jest niezgodne z ideą zrównoważonego rozwoju. Jest to spowodowane brakiem odpowiedniej stabilności technologicznej i niewielką niezawodnością działania.
Źródło:
Archives of Environmental Protection; 2015, 41, 3; 76-82
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cosmetic wastewater treatment using dissolved air flotation
Oczyszczenie ścieków kosmetycznych z wykorzystaniem procesu flotacji ciśnieniowej
Autorzy:
Bogacki, J. P.
Marcinowski, P.
Naumczyk, J.
Wiliński, P.
Powiązania:
https://bibliotekanauki.pl/articles/205185.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wastewater treatment
GC-MS
gas chromatography
cosmetic wastewater
dissolved air flotation
PPCPs
pharmaceutical and personal care pollutants
oczyszczanie ścieków
chromatografia gazowa
ścieki kosmetyczne
flotacja ciśnieniowa
Opis:
Five cosmetics wastewater samples were treated by Dissolved Air Flotation (DAF) assisted by coagulation. Different aluminum based coagulants were used: (Al2(SO4)3, Al 1019, Al 3010, Al 3030, Al 3035, PAX 16 and PAX 19). The raw wastewater COD values were in the range 285–2124 mg/l. The efficiency of DAF depended on different coagulants and production profile of factory. COD removal was varied from 11.1 to 77.7%. The efficiency of coagulants was similar during treatment of particular sample. The best results were obtained with Al2(SO4)3 and for sample 5 – lotions and shampoos production. The wastewater from UV filter creams production (sample 4) was resistant to treatment by DAF regardless of used coagulant. HS-SPME-GC-MS analysis can be a confirmation of DAF effectiveness.
Pięć próbek ścieków kosmetycznych zostało poddanych oczyszczaniu z wykorzystaniem flotacji ciśnieniowej wspomaganej koagulacją. Stosowano różne koagulanty na bazie glinu: Al2(SO4)3, Al 1019, Al 3010, Al 3030, Al 3035, PAX 16 and PAX 19. Wartość ChZT ścieków surowych była w zakresie 285–2124 mg/l. Skuteczność procesu flotacji ciśnieniowej była zależna od zastosowanego koagulantu i profilu produkcji fabryki kosmetyków. Skuteczność usunięcia wartości ChZT była w przedziale 11,1–77,7%. Skuteczność wszystkich koagulantów podczas oczyszczania każdej z próbek ścieków była podobna. Najlepsze rezultaty uzyskano z wykorzystaniem koagulantu Al2(SO4)3 , dla próbki 5 – ścieki pochodzące z produkcji szamponów i logionów. Ścieki z produkcji kremów z filtrem UV (próbka 4) były oporne na oczyszczanie za pomocą procesu flotacji ciśnieniowej, niezależnie od zastosowanego koagulantu. Zastosowana analiza HS-SPME-GC-MS potwierdziła skuteczność oczyszczania z wykorzystaniem flotacji ciśnieniowej.
Źródło:
Archives of Environmental Protection; 2017, 43, 2; 65-73
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oily wastewater treatment using a zirconia ceramic membrane : a literature review
Oczyszczanie ścieków olejowych przy zastosowaniu membran ceramicznych zawierających tlenek cyrkonu : przegląd literaturowy
Autorzy:
Kwaśny, J. A.
Kryłów, M.
Balcerzak, W.
Powiązania:
https://bibliotekanauki.pl/articles/205420.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wastewater treatment
sol-gel method
ultrafiltration
microfiltration
oil-in-water emulsion
oczyszczanie ścieków
metoda zol-żel
ultrafiltracja
mikrofiltracja
emulsja olej-woda
Opis:
The goal of this article was to review the literature which discusses the problem of oily wastewater purification by membrane filtration. The authors focused on membranes containing zirconium compounds, mainly ZrO2, used in pressure driven membrane processes. The efficiency of the oil removal processes for various membranes (ceramic and composite), usually above 95% for the oil contaminated sewage, was compared. The influence of zirconium compounds on the properties of ceramic membranes was also discussed. The methods of producing ceramic membranes have been briefly characterized as well. Ceramic membranes are usually obtained by sol-gel technique but also by isostatic compression, reverse phase technique, or hydrothermal crystallization. Ceramic membranes are formed with zirconia, which cause an increase in filtration efficiency by improvement of hydrophilic properties of the membrane. Moreover, the addition of ZrO2 results in increased chemical and hydrothermal membrane stability. The efficiency of the filtration processes using the presented membranes was high, suggesting that membrane filtration processes are highly effective purification methods.
Artykuł stanowi przegląd literatury, w którym omówiono problem oczyszczania ścieków olejowych w oparciu o filtrację membranową. Skupiono się na membranach ciśnieniowych zawierających związki cyrkonu, głównie ZrO2. Porównano skuteczność procesów oczyszczania dla różnych membran (ceramicznych i kompozytowych). Omówiono wpływ związków cyrkonu na właściwości użytkowe membran ciśnieniowych. Membrany ceramiczne są zwykle uzyskiwane za pomocą techniki zol-żel, ale również przez prasowanie izostatyczne, technikę odwróconej fazy lub krystalizację hydrotermiczną. Membrany ceramiczne są formowane z tlenkiem cyrkonu, co skutkuje wzrostem skuteczności filtracji.
Źródło:
Archives of Environmental Protection; 2018, 44, 3; 3-10
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of wastewater temperature and concentration of organic compounds on the efficiency of ammonium nitrogen removal in a household treatment plant servicing a school building
Wpływ temperatury ścieków oraz związków organicznych na skuteczność usuwania azotu amonowego w przydomowej oczyszczalni przy budynku szkolnym
Autorzy:
Bugajski, Piotr
Kurek, Karolina
Jóźwiakowski, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/205398.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
household wastewater treatment plant
ammonium nitrogen
organic compounds BOD5
air temperature
wastewater temperature
przydomowa oczyszczalnia ścieków
azot amonowy
związki organiczne BZT5
temperatura powietrza
temperatura ścieków
Opis:
The aim of this study was to determine the impact of the temperature of wastewater in a biological reactor with activated sludge and the BOD5/N-NH4 ratio in the influent to the treatment plant on nitrification efficiency and the concentration of ammonium nitrogen in treated wastewater. Tests were carried out in a household wastewater treatment plant which collects and treats sewage from a school building and a teacher’s house. During the 3-year study, large fluctuations in the sewage temperature in bioreactor were noted which was closely related to the ambient temperature. There were also large fluctuations in the concentration of organic matter and the concentration of ammonium nitrogen in inflowing sewage. The influence of wastewater temperature in the bioreactor and the BOD5/N-NH4 ratio on the concentration of ammonium nitrogen in treated wastewater was determined using Pearson’s linear correlation. A statistical analysis showed that a 1°C decrease in the temperature of wastewater in the bioreactor increased the concentration of ammonium nitrogen in treated wastewater by 2.64 mgN-NH4·L-1. Moreover, it was found that nitrification depended on the ratio of BOD5 to the concentration of ammonium nitrogen in wastewater flowing into the bioreactor. An increase in the BOD5/N-NH4 ratio by 1 value led to a 5.41 mgN-NH4·L-1 decrease in the concentration of ammonium nitrogen.
Celem pracy było określenie wpływu temperatury ścieków w reaktorze biologicznym z osadem czynnym oraz stosunku BZT5/N-NH4 w ściekach dopływających do oczyszczalni na skuteczność procesu nitryfikacji i stężenia azotu amonowego w ściekach oczyszczonych. Badania prowadzono w przydomowej oczyszczalni, do której odpływają ścieki z budynku szkolnego oraz domu nauczyciela. W okresie 3-letnich badań odnotowano duże wahania temperatury ścieków w bioreaktorze co było ściśle związane z temperaturą otoczenia. Stwierdzono również duże wahania stężenia materii organicznej oraz stężenia azotu amonowego w ściekach dopływających. Analizę wpływu temperatury ścieków w bioreaktorze oraz stosunku BZT5/N-NH4 na stężenie azotu amonowego w ściekach oczyszczonych określono za pomocą korelacji liniowej Persona. W wyniku przeprowadzonej analizy statystycznej stwierdzono, że wraz obniżeniem temperatury ścieków w bioreaktorze o 1°C następuje zwiększenie stężenia azotu amonowego w ściekach oczyszczonych o 2,64 mgN-NH4·L-1. Ponadto stwierdza się, że proces nitryfikacji zależny jest od stosunku BZT5 do stężenia azotu amonowego w ściekach dopływających do bioreaktora. Wraz ze wzrostem zależności BZT5/N-NH4 o 1 maleje stężenie stężenia azotu amonowego o 5,41 mgN-NH4·L-1
Źródło:
Archives of Environmental Protection; 2019, 45, 3; 31-37
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Treatment of wastewater from service areas at motorways
Oczyszczanie ścieków z miejsc obsługi podróżnych przy autostradzie
Autorzy:
Makowska, M.
Mazurkiewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/205279.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
motorway service areas
local treatment plants
biofilters
wastewater treatment
facilities at transport routes
miejsca obsługi podróżnych
MOP
natężenie ruchu
autostrada A2
oczyszczalnie lokalne
biofiltr
jakość ścieków
Opis:
This paper deals with wastewater treatment systems placed in motorway service areas (MSAs). In the years 2008-2009 eight of such facilities installed on the stretch of the A2 motorway between Poznań and Nowy Tomyśl were examined and analyzed. The system consists of a septic tank, a submerged aerated biofilter and an outflow filter. The volume of traffic on the highway was analyzed, the amount of water use was measured and peak factors were calculated. On this basis it was concluded that the inflows to the wastewater treatment systems in many cases exceeded the nominal design values. Based on the analysis of effluent quality it was found that the effects of plant operation in large part did not meet the requirements. It was found that the bioreactor aeration system and the design of the suspension separator (outflow filter) should be modified. One of the solutions was to use the soil-reed bed for wastewater treatment. The treatment of wastewater from the MSAs is a task that must take into account the unusual character of these facilities and the atypical quality of the effluent.
Praca dotyczy systemów oczyszczania ścieków w Miejscach Obsługi Podróżnych (MOP) przy autostradach. Badano i analizowano 8 instalacji zamontowanych w MOP-ach przy autostradzie A2 między Poznaniem a Nowym Tomyślem. Systemy składają się z osadnika gnilnego, zanurzonego, napowietrzanego złoża biologicznego i filtra odpływowego. Analizowano natężenie ruchu na autostradzie, ilość zużywanej wody oraz jakość ścieków na wlocie i wylocie z bioreaktora. Na tej podstawie stwierdzono, że wielkość oczyszczalnie nie jest adekwatna do ilości i jakości dopływających ścieków. Stwierdzono, że jakość odpływu jest niezadowalająca oraz zaproponowano zmiany konstrukcyjne i technologiczne.
Źródło:
Archives of Environmental Protection; 2016, 42, 4; 80-89
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the impact of explanatory variables on the accuracy of prediction of daily inflow to the sewage treatment plant by selected models nonlinear
Ocena wpływu zmiennych objaśniających na dokładność predykcji dobowego dopływu do oczyszczalni ścieków wybranymi modelami nieliniowymi
Autorzy:
Szeląg, B.
Bartkiewicz, L.
Studziński, J.
Barbusiński, K.
Powiązania:
https://bibliotekanauki.pl/articles/205349.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wastewater treatment plant
data mining
random forest
forecasting inflow
k-nearest neighbour
Kernel regression
oczyszczalnia ścieków
wydobywanie danych
las losowy
dopływ ścieków
modelowanie
k-najbliższy sąsiad
regresja Kernela
Opis:
The aim of the study was to evaluate the possibility of applying different methods of data mining to model the inflow of sewage into the municipal sewage treatment plant. Prediction models were elaborated using methods of support vector machines (SVM), random forests (RF), k-nearest neighbour (k-NN) and of Kernel regression (K). Data consisted of the time series of daily rainfalls, water level measurements in the clarified sewage recipient and the wastewater inflow into the Rzeszow city plant. Results indicate that the best models with one input delayed by 1 day were obtained using the k-NN method while the worst with the K method. For the models with two input variables and one explanatory one the smallest errors were obtained if model inputs were sewage inflow and rainfall data delayed by 1 day and the best fit is provided using RF method while the worst with the K method. In the case of models with three inputs and two explanatory variables, the best results were reported for the SVM and the worst for the K method. In the most of the modelling runs the smallest prediction errors are obtained using the SVM method and the biggest ones with the K method. In the case of the simplest model with one input delayed by 1 day the best results are provided using k-NN method and by the models with two inputs in two modelling runs the RF method appeared as the best.
Celem pracy jest ocena możliwości zastosowania różnych metod data mining do modelowania dopływu ścieków do komunalnej oczyszczalni ścieków. Do opracowania modeli statystycznych metodą wektorów nośnych, lasów losowych, k – najbliższego sąsiada i regresji Kernela wykorzystano szeregi pomiarowe dobowych wartości opadów deszczu, stanów wody w odbiorniku oraz dopływów do komunalnej oczyszczalni ścieków w Rzeszowie. Z obliczeń wykonanych metodami SVM, RF, k-NN i K wynika, że dla modeli z jedną zmienną objaśniającą opóźnioną o dobę w stosunku do wartości dopływu, najlepsze wyniki otrzymano modelem autoregresyjnym bazującym na metodzie k-NN a najgorsze regresją Kernela. W przypadku modeli z dwoma zmiennymi objaśniającymi najmniejsze wartości błędów uzyskano, dla modeli uwzględniających dopływ ścieków i całkowitą wysokość opadu deszczu z jednodobowym opóźnieniem; najlepsze wyniki uzyskano metodą RF a najgorsze regresji Kernela. Dla modeli z dwiema zmiennymi objaśniającymi, ale trzema sygnałami wejściowymi, najmniejsze błędy dopływu ścieków do OŚ uzyskano metodą SVM, a najgorsze regresji Kernela. Z wykonanych symulacji stwierdzono, że w większości przypadków najmniejsze wartości błędów dopływu ścieków do oczyszczalni otrzymano metodą SVM a największe metodą K. W przypadku najprostszego modelu z jednym sygnałem wejściowym opóźnionym o 1 dobę najlepsze wyniki obliczeń uzyskano metodą k-NN, a w dwóch przypadkach modeli, gdzie ujęto 2 sygnały wejściowe, najlepsza okazała się metoda RF.
Źródło:
Archives of Environmental Protection; 2017, 43, 3; 74-81
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determinants of environmental assessment of Polish individual wastewater treatment plants in a life cycle perspective
Determinanty oceny środowiskowej krajowych indywidualnych oczyszczalni ścieków uwzględniając perspektywę cyklu życia
Autorzy:
Burchart-Korol, Dorota
Zawartka, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/205478.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
life cycle assessment
individual wastewater treatment plants
life cycle inventory
environmental impact categories
cradle to grave
szacowanie cyklu życia
indywidualne oczyszczalnie ścieków
inwentaryzacja cyklu życia
oddziaływanie na środowisko
Opis:
The article presents results of an input-output data inventory and life cycle assessment (LCA) for individual wastewater treatment plants (IWWTPs), considering their whole life cycle, including the stage of construction, use and end-of-life. IWWTPs located in the area of a medium-sized town in Poland, were assessed from a systemic perspective. The research was conducted basing on actual data concerning performance of 304 individual wastewater treatment plants in Żory. Environmental assessment was conducted with ReCiPe and TRACI methods. Greenhouse gases (GHG) emission, eutrophication, fossil fuel and metal depletion were calculated. The LCA was conducted basing on ISO 14040 standard with SimaPro 8 software and Ecoinvent 3 database. The system boundary ranged from cradle to grave. It was shown that, at the construction stage, GHG emission depends on the amount of used cement, polyethylene, concrete, PVC and polypropylene. At the use stage, the GHG emission is determined by the sewage treatment technology and application of a bio-reactor in IWWTPs. At the construction stage, the fossil fuel depletion is determined by the amount of used polyethylene, PVC, cement, polypropylene and concrete; while the metal depletion is determined by the amount of used stainless steel, copper and cast iron. Data inventory and LCA of IWWTPs are presented for the fi rst time. Conclusions of the work may support decisions taken by local governments concerning wastewater management in their area and promote and support solutions of high ecological standards.
W artykule przedstawiono wyniki inwentaryzacji danych oraz środowiskowej oceny cyklu życia (LCA) indywidualnych oczyszczalni ścieków (IWWTP), z uwzględnieniem całego ich cyklu życia, w tym etapu budowy, użytkowania i wycofania z eksploatacji. IWWTP zlokalizowane na terenie średniej wielkości miasta w Polsce, zostały ocenione z perspektywy cyklu życia. Wykazano, że na etapie budowy IWWTP emisja gazów cieplarnianych jest zależna od ilości użytego cementu, polietylenu, betonu, PCV i polipropylenu. Na etapie budowy zużycie paliw kopalnych zależy od ilości zużytego polietylenu, PCV, cementu, polipropylenu i betonu; natomiast zużycie metali zależy od ilości użytej stali nierdzewnej, miedzi i żeliwa. Na etapie użytkowania determinantami emisji gazów cieplarnianych są technologia oczyszczania ścieków i zastosowanie bioreaktora w IWWTP. Dane inwentaryzacyjne i analiza cyklu życia IWWTP są prezentowane po raz pierwszy w literaturze. Wnioski z pracy mogą służyć do podejmowania decyzji przez samorządy dotyczących gospodarki wodno-ściekowej na ich terenie oraz promowania i wspierania rozwiązań proekologicznych.
Źródło:
Archives of Environmental Protection; 2019, 45, 3; 44-54
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies