Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "WF" wg kryterium: Temat


Wyświetlanie 1-1 z 1
Tytuł:
Economic based evaluation of DGs in capacitor allocated optimal distribution network
Autorzy:
Srinivasan, G.
Amaresh, K.
Cheepati, Kumar Reddy
Powiązania:
https://bibliotekanauki.pl/articles/2173535.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ISSOT-WF
capacitor placement
capacitor sizing
feeder reconfiguration
dispersed generation
electrical distribution network
additional power loss reduction
rozmieszczenie kondensatorów
wymiarowanie kondensatorów
rekonfiguracja podajnika
generacja rozproszona
sieć dystrybucji energii
redukcja strat mocy
Opis:
Feeder reconfiguration (FR), capacitor placement and sizing (CPS) are the two renowned methods widely applied by the researchers for loss minimization with node voltage enrichment in the electrical distribution network (EDN), which has an immense impact on economic savings. In recent years, optimization of FR and CPS together can proficiently yield better power loss minimization and save costs compared to the individual optimization of FR and CPS. This work proposes an application of an improved salp swarm optimization technique based on weight factor (ISSOT-WF) to solve the cost-based objective function using CPS with and without FR for five different cases and three load levels, subject to satisfying operating constraints. In addition, to ascertain the impact of real power injection on additional power loss reduction, this work considers the integration of dispersed generation units at three optimal locations in capacitive compensated optimal EDN. The effectiveness of ISSOT-WF has been demonstrated on the standard PG&E-69 bus system and the outcomes of the 69-bus test case have been validated by comparing with other competing algorithms. Using FR and CPS at three optimal nodes and due to power loss reduction, cost-saving reached up to a maximum of 71%, and a maximum APLR of 26% was achieved after the installation of DGs at three optimal locations with the significant improvement in the bus voltage profile.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2022, 70, 1; e139053, 1--10
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies