Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Inverter" wg kryterium: Temat


Tytuł:
Three-phase soft-switching inverter with coupled inductors, experimental results
Autorzy:
Karyś, S.
Powiązania:
https://bibliotekanauki.pl/articles/200045.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
soft-switching
resonant inverter
ZVS inverter
Opis:
This paper presents experimental results of the three-phase soft-switching inverter with coupled inductors that verify the control method influence on efficiency improvement. Different kinds of control methods were tested on the 6 kW experimental inverter. A short discussion on a few design methods of the resonant tank elements was made. Experimental results confirm that the advanced control algorithm and the proposed new design method of the resonant tank elements significantly increase the efficiency of this resonant inverter.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2011, 59, 4; 535-540
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Regulacja wydajności urządzeń potrzeb własnych elektrowni cieplnych asynchronicznymi napędami falownikowymi średniego napięcia
Variable speed drives with frequency converters in thermal power plant auxiliaries
Autorzy:
Wawszczak, A.
Powiązania:
https://bibliotekanauki.pl/articles/173004.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
elektrownia cieplna
napęd falownikowy
przemiennik
thermal power station
inverter drive
inverter
Opis:
Omówiono możliwości regulacji wydajności urządzeń potrzeb własnych elektrowni cieplnych napędzanych klatkowymi silnikami indukcyjnymi zasilanymi przemiennikami częstotliwości. Skupiono się głównie na napędach średnionapięciowych (6÷10 kV) dużej mocy. Przedstawiono aktualną ofertę przemienników czołowych światowych producentów. Oceniono możliwości wykorzystania tego typu napędów w dużych, nowoczesnych elektrowniach blokowych.
The paper introduces current potential of variable speed drives (VSD) intended for squirrel cage induction motors supplied by frequency converters in thermal power plant auxiliaries. The paper is mostly focused on medium-voltage (6-10 kV) and high-power drives. Current tender of leading world producers in this field has been presented. Possibility to apply this type of drives in large, modern block-power plants has been considered.
Źródło:
Archiwum Energetyki; 2013, 43, 1/2; 87-99
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
GaN-based soft-switched active power buffer operating at ZCS – problems of start-up and shut-down
Autorzy:
Rąbkowski, J.
Król, K.
Zdanowski, M.
Sochacki, M.
Powiązania:
https://bibliotekanauki.pl/articles/201868.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
GaN
power inverter
active buffer
Opis:
This paper describes practical issues related to control of the active power buffer (APB) developed for a 2 kVA single-phase inverter. The buffer is designed using the latest GaN HEMTs controlled with triangular current mode to reduce switching losses, however, the switching frequency should be limited to 1 MHz. In the case of the presented analogue-digital controller, frequency is influenced by a reference current of the APB and circuit. Therefore, the operation at start-up and shut-down is especially challenging. A modified control algorithm that also includes pre-charging and discharging process of the energy buffer is presented and experimentally verified by series of tests of the 2 kVA GaN based inverter with the APB.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 4; 785-792
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multiphase Z-source inverter using maximum constant boost control
Autorzy:
Kouzou, A.
Abu-Rub, H.
Powiązania:
https://bibliotekanauki.pl/articles/229291.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Z-source inverter
multiphase inverter
five phase machine
shoot-through
boost factor
duty cycle
Opis:
This paper deals with the impedance source (Z-source) multiphase inverter, where the maximum constant boost control method is studied and analyzed in the general case of number of phases. On the other side the impact of the modulation index and the number of phases on the duty cycle shoot-through and on the gain of the output voltage ranges is presented. To validate advantages of the Z-source multiphase inverter, the proposed topology and the maximum constant boost control are implemented in simulation and in real time experimentation with Z-source five phase inverter. The output voltage is applied to two parallel loads, a five phase resistive load and a five phase induction machine.
Źródło:
Archives of Control Sciences; 2013, 23, 1; 107-126
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modern Direct Torque and Flux Control methods of an induction machine supplied by three-level inverter
Autorzy:
Sikorski, A.
Kulikowski, K.
Korzeniewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/201199.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
asynchronous machine
DC/AC inverter
DTC
flux and torque control
3-level DC/AC inverter
Opis:
This paper describes two modern direct torque and flux control methods of an induction machine supplied by a three-level inverter. Additionally, it presents a comparison of the methods both in static and dynamic states. The methods, in a specific way, make use of an increased number of active vectors of the three-level inverter in order to improve control quality and reduce switching frequency. The two methods modify the DTC method by using its advantages and eliminating, at the same time its drawbacks. In static states the comparison was based on the results of investigations performed for two different load values and three set values of angular speed, whereas in dynamic states the comparison was focused on the behavior of the machine at startup. The results of the investigations have shown that both methods give very good performance. They are characterized by both sinusoidal shape of flux and low current deformations even at low angular speeds i.e. less than 10% of the nominal value. The presented methods also allow to generate nominal flux for set zero angular speed in order to achieve excitation of the induction machine. The switching frequencies for both methods are very similar in almost the whole range of control but the methods have shown some differences in control quality, particularly for higher torque values.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 4; 771-778
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of harmonic voltage coupling on torque ripple of permanent magnet synchronous motor
Autorzy:
Geng, Shengtao
Zhang, Yong
Qiu, Hongbo
Yang, Cunxiang
Yi, Ran
Powiązania:
https://bibliotekanauki.pl/articles/140572.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
PMSM
harmonic voltage coupling
torque ripple
inverter
Opis:
The permanent magnet synchronous motor (PMSM) driven by an inverter is widely used in the industrial field, but the inverter has a significant impact on the operational stability of the PMSM. The torque ripple of the PMSM is directly affected by the coupling of multiple harmonic voltages in the motor windings. In order to analyze its influence, a water-cooled PMSM with 20 kW 2000 r/min is taken as an example to establish the finite element model of the prototype, and the correctness of the model is verified by experiments. Firstly, based on the finite element method, the electromagnetic field of the PMSM is numerically solved in different operating states, and the performance parameters of the PMSM are obtained. Based on these parameters, the influence of the harmonic voltage amplitude on the torque ripple is studied, and the influence law is obtained. Secondly, combined with the decoupling analysis method, the influence of harmonic voltage coupling on the torque ripple is compared and analyzed, and the variation law of harmonic voltage coupling on the torque ripple is obtained. In addition, the influence of different harmonic voltage coupling on the average torque of the PMSM is studied, and the influence degree of different harmonic voltage amplitude on the torque fluctuation is determined. The conclusion of this paper provides reliable theoretical guidance for improving motor performance.
Źródło:
Archives of Electrical Engineering; 2019, 68, 2; 399-410
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel in-phase disposition SPWM pulse allocation strategy for cascaded H-bridge inverter
Autorzy:
Zhang, Y.
Xiong, J.
Kong, L.
Wang, X.
Powiązania:
https://bibliotekanauki.pl/articles/141155.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
in-phase disposition SPWM
Inverter
CHB
THD
Opis:
A novel in-phase disposition (IPD) SPWM pulse allocation strategy applied to a cascaded H-bridge (CHB) converter is presented in this paper. The reason causing the power of the CHB converter imbalance is analyzed according to the traditional structure, the conception of power imbalance degree is introduced and the principle of the novel in-phase disposition SPWM allocation strategy is deduced in detail. The new pulse allocation scheme can ensure the power balance in 3/4 cycles through interchanging the PWM pulse sequence of the different CHB cell, meanwhile it makes the full advantage of the IPD control strategy, lower the total harmonic distortion (THD) of line voltage compared to a carrier phase shifted (CPS) control strategy, which is verified by theoretical derivation. A seven-level cascaded inverter composed by three H-bridge cells is taken as the example. The simulation and experiment is performed. The results indicate the validity of the analysis and verify the effectiveness of the proposed SPWM allocation strategy.
Źródło:
Archives of Electrical Engineering; 2018, 67, 2; 361--375
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A predictive estimation based control strategy for a quasi-resonant dc-link inverter
Autorzy:
Turzyński, M.
Banach, P.
Murawski, P.
Pepliński, R.
Chrzan, P. J.
Powiązania:
https://bibliotekanauki.pl/articles/200484.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
resonant converters
ZVS three-phase inverter
current estimation
Opis:
Control of parallel quasi resonant dc link inverters (PQRDCLI) is usually based on dc link input inverter current. Instead of a direct measurement of this noise sensitive and fast changing current signal - its estimation with one step prediction may be considered. Estimation of an input inverter current is based on inverter output current measurements, applied in most of power electronics controlled ac drives. In this paper, the PQRDCLI fed induction motor (IM) with a predictive current estimation stabilizes resonant inverter output voltage slopes du/dt independently of load. By control of output voltage derivatives, reduction of overvoltage spikes and common mode motor currents is achieved. An analysis of the PQRDCLI control with a predictive current estimation strategy is verified by the Saber system simulation and experimental tests in a laboratory setup.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 4; 757-762
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling and simulation of novel stepped DC coupled quasi Z-Multilevel Inverter for single phase systems
Autorzy:
Meenakshi, T.
Suthanthira Vanitha, N.
Powiązania:
https://bibliotekanauki.pl/articles/140968.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multilevel inverter
shoot through
quasi Z-Source
modulation index
Opis:
This paper presents the modeling and simulation of a novel topology of quasi Z-Multilevel Inverter with stepped DC input. The proposed inverter incorporates a simple switching technique with reduced component count and is aimed at producing boosted multilevel output AC voltage. The inverter consists of two stages and the buck /boost operation is obtained by varying the shoot through period of the pulses obtained by maximum constant boost control with third harmonic injection. With all the advantages of the quasi Z-network, the proposed inverter eliminates the fly back diodes and capacitors present in a conventional Z-Multilevel Inverter. Further the stress on the devices is less which leads to reduction in component value and hence the cost. The novel stepped DC coupled Single Phase quasi Z-Multilevel Inverter is modeled and simulated in the MATLAB – SIMULINK environment and its performance is analyzed for varying input and switching conditions. The voltage and current waveforms across each stage of the inverter is analyzed and the results are presented for different levels of input.
Źródło:
Archives of Electrical Engineering; 2016, 65, 3; 437-448
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of space vector modulation strategy on hybrid (Si-SiC) inverter losses
Autorzy:
Bonisławski, M.
Hołub, M.
Powiązania:
https://bibliotekanauki.pl/articles/140592.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
przekształtnik hybrydowy
elektronika energetyczna
urządzenie z szeroką przerwą energetyczną
SVPWM
DPWM
power electronic inverter
SiC diodes
hybrid inverter
wide band gap devices
Opis:
This work summarizes efficiency measurement results of a full bridge, 3 phase inverter composed of state-of-the-art Si IGBT transistors and Si or SiC diodes. Different (symmetrical and discontinuous) space vector modulation strategies were chosen in order to examine their influence (together with modulation frequency) on inverter losses. Induction machine was used as load, different load points were examined. Results clearly show, that proper modulation strategy, minimizing the switching losses of semiconductor switches, can increase the overall output efficiency at about 1% in case of both silicon and hybrid constructions. The drawback of DPWM approach is connected with the decreased quality of inverter output current. Hybrid technology can also improve the output efficiency at about 1% when compared to traditional constructions, but only in case of elevated switching frequencies. At low frequencies (below 10 kHz) modern semiconductor offer comparable results at much lower device costs.
Źródło:
Archives of Electrical Engineering; 2012, 61, 1; 69-75
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A closed-loop power controller model of series-resonant-inverter-fitted induction heating system
Autorzy:
Pal, P.
Roy, D.
Datta, A.
Sadhu, P. K.
Banerjee, A.
Powiązania:
https://bibliotekanauki.pl/articles/141721.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
induction heating
power controller
PID
series resonant inverter
MATLAB
Opis:
This paper presents a mathematical model of a power controller for a high-frequency induction heating system based on a modified half-bridge series resonant inverter. The output real power is precise over the heating coil, and this real power is processed as a feedback signal that contends a closed-loop topology with a proportional-integral-derivative controller. This technique enables both control of the closed-loop power and determination of the stability of the high-frequency inverter. Unlike the topologies of existing power controllers, the proposed topology enables direct control of the real power of the high-frequency inverter.
Źródło:
Archives of Electrical Engineering; 2016, 65, 4; 827-841
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An evaluation of the accuracy of inverter sync angle during the grids disturbances
Autorzy:
Jarzyna, Wojciech
Zieliński, Dariusz
Gopakumar, K.
Powiązania:
https://bibliotekanauki.pl/articles/221529.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
inverter synchronization
synchronization angle
PLL
sync error
distributed grid
Opis:
The grid-tied inverter synchronizes with the network on the basis of the instantaneous voltage phase angle. This angle is computed by the so-called synchronization algorithms. During grid disturbances, it is estimated with a certain accuracy, which varies for different disturbances and depends on the choice of algorithm. The tests presented here determine how to make an optimal selection of the synchronization algorithm. The research methods used are modeling, simulation and analysis of the results obtained. One of the most important outcomes is the determination of the root-mean-square sync error and its dynamics denotation. The research conclusions should be of particular interest to designers of distributed energy systems with a large number of inverter energy sources.
Źródło:
Metrology and Measurement Systems; 2020, 27, 2; 355-371
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on topology of a novel three-phase four-leg fault-tolerant NPC inverter
Autorzy:
Zhang, Baoge
Ping, Shanyan
Long, Yyi
Jiao, Yyuemin
Wu, Bboxiang
Powiązania:
https://bibliotekanauki.pl/articles/2086722.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
fault tolerant operation
midpoint potential equilibrium
NPC inverter
topology reconstruction
Opis:
Diode neutral point clamped (NPC) three-level converters have been widely used in recent years. Aiming at the problems of the high device failure rate and unstable neutral point potential of NPC three-level converters, an NPC three-level circuit with fourth bridge arm redundancy is proposed based on the traditional NPC three-level converter. The redundant fourth bridge arm is used to realize the function of stabilizing voltage when there is no fault and replacing the fault half-bridge arm to maintain the continuous operation of the converter when there is a fault. By analyzing the working principle of space vector pulse width modulation (SVPWM) and the power loss of the switch, it is of particular significance to the design and control of NPC three-level converters in the future. Matlab/Simulink verifies the feasibility of the fault-tolerant circuit structure.
Źródło:
Archives of Electrical Engineering; 2022, 71, 2; 489--506
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Steady-state time-periodic finite element analysis of a brushless DC motor drive considering motion
Autorzy:
Jagieła, M.
Gwóźdź, J.
Powiązania:
https://bibliotekanauki.pl/articles/141576.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
finite elements
brushless machines
inverter drives
steady-state
mathematical modeling
Opis:
This paper aims at providing a framework for comprehensive steady-state time-domain analysis of rotating machines considering motion. The steady-state waveforms of electromagnetic and circuit quantities are computed via iterative solution of the nonlinear field-circuit-and-motion problem with constraints of time periodicity. The cases with forced speed and forced load torque are considered. A comparison of execution times with a conventional time-stepping transient model is carried out for two different machines. The numerical stability of a time-periodic model with forced speed is shown to be worse than that of traditional transient time-stepping one, although the model converges within a reasonable number of iterations. This is not the case if forced load via equation of mechanical balance is accounted for. To ensure convergence of the iterative process the physical equation of motion is replaced by the fixed-point equation. In this way the model delivers time-periodic solutions regarding not only the electromagnetic quantities but also the rotational speed.
Źródło:
Archives of Electrical Engineering; 2015, 64, 3; 471-486
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency of maximum power point tracking in photovoltaic system under variable solar irradiance
Autorzy:
Marańda, W.
Piotrowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/200627.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
photovoltaics
MPP-tracking
inverter efficiency
fotowoltaika
śledzenie
MPP
sprawność falownika
Opis:
Field conditions decrease the energy output of photovoltaic (PV) systems, mainly due to excessive temperatures. However, in regions with moderate ambient temperatures, as in Poland, solar energy is commonly delivered with highly fluctuating irradiance. This introduces yet another source of energy losses due to the non-ideal tracking of actual position of Maximum Power Point (MPP). Majority of PV-systems are equipped with DC/AC and grid-connected inverter. Since the solar energy flux is variable, an adequate MPP-tracking algorithm is required to handle a wide range of load levels and face rapid changes of input power. Along with the essential DC/AC conversion, the quality of MPP-tracking must also be taken into account in evaluation of inverter efficiency. The tracking in dynamic conditions has been addressed only recently. Several algorithms has been studied theoretically, experimentally or in laboratory conditions by applying artificial input test-patterns. This work takes the opposite approach by applying the recorded real-life solar irradiance and simulating the tracking behavior to study the problem for true field conditions in Poland. The simulation uses the unique high-quality irradiance data collected with 200 ms time resolution. The calculation of both static and dynamic MPP-tracking efficiency has been performed for representative variable-cloudy day, applying commonly used Perturb&Observe tracking algorithm.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2014, 62, 4; 713-721
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies