Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Economic power" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Sizing of prosumer hybrid renewable energy systems in Poland
Autorzy:
Bartecka, M.
Terlikowski, P.
Kłos, M.
Michalski, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/200243.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
hybrid renewable energy system
prosumer
energy efficiency
techno-economic analysis
optimal power source sizing
Opis:
Nowadays the demand for renewable energy sources is constantly growing. There are several reasons of such state, including requirements for energy-efficient new buildings and reduction of greenhouse gas emissions. An exemplary solution that may help to reduce “traditional” primary energy consumption is local energy source utilization. The article presents a simplified feasibility study of hybrid energy system under Polish law and economic conditions for a self-government unit, that is legally obliged to apply means of energy efficiency improvement. The aim of this paper is to provide a simple algorithm to find optimal hybrid PV and wind power source sizing for a prosumer. Resource data used in analyses are imported from Photovoltaic Geographical Information System and cover a period of one year. The paper includes two different methodologies applied to solve the problem of optimal hybrid energy system sizing. The first approach is heuristic and based on monthly energy balancing while the second is iterative and takes into account hourly energy balance. The results from both methods are compared and verified by HomerPro software, that shows significant differences between two algorithms. At the end economic assessment based on Net Present Value method is performed.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 4; 721-731
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Economic and Exploitation Aspects of Reactive Power Compensation Consumed by Laboratory Roller Mixer
Autorzy:
Ziółkowski, E.
Bień, A.
Smyksy, K.
Wrona, R.
Powiązania:
https://bibliotekanauki.pl/articles/381941.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
laboratory roller mixer
reactive power compensation
economic analysis
mieszarka rolkowa
kompensacja mocy biernej
analiza ekonomiczna
Opis:
Results of measurements of selected electrical parameters in supply system of laboratory roller mixer (IODi AGH type) during its operation are presented. Basing on the analysis of measured electric parameters and energy consumption the compensation capacitors system was chosen. The effect of improving the power factor cosφ (and also tgφ) has achieved. After capacitors installation in supply system of the mixer drive the measurements of electric parameters and analysis of harmonic of voltage and current were realised. The results were compared with the limit values from electromagnetic compatibility (EMC) standard PN-EN61000-3-2. The economic and operational effects of reactive power compensation in supply system of the mixer have been highlighted.
Źródło:
Archives of Foundry Engineering; 2015, 15, 3 spec.; 103-106
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena ekonomiczna nadkrytycznego bloku węglowego dużej mocy zintegrowanego w różnych konfiguracjach z CCS oraz z odzyskiem ciepła ze spalin
An economic analysis of a high capacity coal-fired power unit for supercritical steam parameters integrated in different configurations with the carbon capture system (CCS) and with heat recovery from the organic Rankine cycle (ORC) exhaust gases
Autorzy:
Kochaniewicz, A.
Łukowicz, H.
Powiązania:
https://bibliotekanauki.pl/articles/172847.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
nadkrytyczny blok węglowy
CCS
ORC
odzysk ciepła
ocena ekonomiczna
supercritical power plant
heat recovery
economic assessment
Opis:
W pracy dokonano analizy wskaźników opłacalności ekonomicznej budowy bloków węglowych o parametrach nadkrytycznych opalanych węglem kamiennym i brunatnym. Przeanalizowano trzy warianty konfiguracji bloku, tj.: blok wyjściowy, blok wyjściowy+CCS i blok wyjściowy+ CCS+ORC.W analizie ekonomicznej wykorzystano tzw. próg rentowności BEP (break even point), bazującego na określeniu punktu wyrównania, określającego sytuację w której przychody ze sprzedaży energii elektrycznej pokrywają koszty stałe i koszty zmienne instalacji. Dokonano oceny wpływu zmiany wybranych parametrów takich jak: jednostkowe nakłady inwestycyjne, cena zakupu uprawnień do emisji CO2, a także wpływu ceny paliwa. Dla tych wszystkich uzmiennionych parametrów określono wpływ ich zmian na graniczną cenę sprzedaży energii elektrycznej. Analizie poddano samodzielny oraz po jego zintegrowaniu z CCS (carbon dioxide capture and storage) wysokosprawny nadkrytyczny blok węglowy o mocy 900 MW. Analizowano także wpływ integracji bloku energetycznego z siłownią ORC (organic Rankine cycle) i podjęto próbę określenia jego efektywności ekonomicznej, przy czym przyjęto, że obieg ORC zasilany jest ciepłem odpadowym ze spalin wylotowych z kotła.
This paper presents the analysis of the indices of the economic profitability of the construction of brown- and hard coal-fired power plants for supercritical steam parameters. Three variants of the power plant configuration are analysed within this study: the initial power plant, the initial power plant + CCS, the initial power plant + CCS + ORC. The economic analysis employs the break-even point (BEP), which is based on the determination of the point of balance between the income from the sale of electricity and the plant fixed and variable costs. The impact of change in selected parameters, such as investment expenditures per unit, the price of the CO2 emissions allowances and the price of fuel, is analysed. The effect of changes in all these variable parameters on the minimum selling price of electricity is determined. The analysis concerns a high efficiency 900 MW coal-fired power unit for supercritical steam parameters as the initial plant and its variant after integration with the CCS. The impact of a further integration of the power unit with an ORC plant is analysed and an attempt is made to determine the economic efficiency of such integration. It is assumed that the ORC is fed with the waste heat from the boiler exhaust gases.
Źródło:
Archiwum Energetyki; 2013, 43, 1/2; 157-169
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Smart control of energy storage system in residential photovoltaic systems for economic and technical efficiency
Autorzy:
Kaczorowska, Dominika
Rezmer, Jacek
Janik, Przemysław
Sikorski, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2202548.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
economic efficiency
energy storage system ESS
microgrid management
optimal power flow
OPF
particle swarm optimisation PSO
Opis:
In recent years, due to the increasing number of renewable energy sources, which are characterised by the stochastic nature of the generated power, interest in energy storage has increased. Commercial installations use simple deterministic methods with low economic efficiency. Hence, there is a need for intelligent algorithms that combine technical and economic aspects. Methods based on computational intelligence (CI) could be a solution. The paper presents an algorithm for optimising power flow in microgrids by using computational intelligence methods. This approach ensures technical and economic efficiency by combining multiple aspects in a single objective function with minimal numerical complexity. It is scalable to any industrial or residential microgrid system. The method uses load and generation forecasts at any time horizon and resolution and the actual specifications of the energy storage systems, ensuring that technological constraints are maintained. The paper presents selected calculation results for a typical residential microgrid supplied with a photovoltaic system. The results of the proposed algorithm are compared with the outcomes provided by a deterministic management system. The computational intelligence method allows the objective function to be adjusted to find the optimal balance of economic and technical effects. Initially, the authors tested the invented algorithm for technical effects, minimising the power exchanged with the distribution system. The application of the algorithm resulted in financial losses, €12.78 for the deterministic algorithm and €8.68 for the algorithm using computational intelligence. Thus, in the next step, a control favouring economic goals was checked using the CI algorithm. The case where charging the storage system from the grid was disabled resulted in a financial benefit of €10.02, whereas when the storage system was allowed to charge from the grid, €437.69. Despite the financial benefits, the application of the algorithm resulted in up to 1560 discharge cycles. Thus, a new unconventional case was considered in which technical and economic objectives were combined, leading to an optimum benefit of €255.17 with 560 discharge cycles per year. Further research of the algorithm will focus on the development of a fitness function coupled to the power system model.
Źródło:
Archives of Electrical Engineering; 2023, 72, 1; 81--102
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza efektywności energetycznej i ekonomicznej elektrociepłowni gazowo-parowej zintegrowanej ze zgazowaniem biomasy
Energy and economic effectiveness analysis of gas-steam combined heat and power plant integrated with biomass gasification
Autorzy:
Zaporowski, B.
Powiązania:
https://bibliotekanauki.pl/articles/172913.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
elektrociepłownia gazowo-parowa
zgazowanie biomasy
efektywność energetyczna
efektywność ekonomiczna
gas-steam power plant
biomass gasification
energy effectiveness
economic effectiveness
Opis:
W artykule jest przedstawiona analiza efektywności energetycznej i ekonomicznej elektrociepłowni gazowo-parowej zintegrowanej ze zgazowaniem biomasy. W pierwszej części pracy zostały wyznaczone następujące wielkości charakteryzujące efektywność energetyczną procesu zgazowania biomasy: skład wytwarzanego gazu, wartość współczynnika nadmiaru czynnika zgazowującego, zużycie czynnika zgazowującego na 1 kg biomasy, objętość gazu uzyskiwana z 1 kg biomasy, wartość opałowa wytwarzanego gazu oraz sprawność chemiczna i energetyczna procesu zgazowania. W drugiej części została wykonana analiza efektywności energetycznej ciepłowniczego bloku gazowo-parowego z dwuciśnieniowym kotłem odzysknicowym i upustowo-kondensacyjną turbiną parową, zintegrowanego ze zgazowaniem biomasy. W trzeciej części zostały wyznaczone następujące wielkości charakteryzujące efektywność ekonomiczną analizowanego bloku ciepłowniczego: wielkość bieżąca netto, wewnętrzna stopa zwrotu oraz jednostkowe, zdyskontowane na rok 2012, koszty wytwarzania energii elektrycznej.
The paper presents the energy and economic effectiveness analysis of gas-steam combined heat and power (CHP) plant integrated with biomass gasification. In the first part of the paper there have been determined the following quantities characterizing the energy effectiveness of biomass gasification process: composition of gas, gasifying agent excess ratio, gasifying agent consumption per 1 kg of biomass, volume of gas obtained from 1 kg of biomass, lower heating value of gas and chemical and energy efficiencies of biomass gasification process. In the second part of the paper there has been made the analysis of energy effectiveness of gas-steam CHP block integrated with biomass gasification with two-pressure heat recovery steam generator (HRSG) and extraction condensing steam turbine. In the third part of the paper there have been determined the following quantities characterizing the economic effectiveness of the analyzed CHP block: net present value (NPV), internal rate of return (IRR) and unitary, discounted of 2012 year, electricity generation costs.
Źródło:
Archiwum Energetyki; 2012, 42, 2; s. 121-130
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies