Tytuł:
Cooling water flow influence on power plant unit performance for various condenser configurations setup
Autorzy:
Dobkiewicz-Wieczorek, Ewa
Powiązania:
https://bibliotekanauki.pl/articles/2091367.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cooling water
power plant efficiency
cooling water flow control
CHP plant
efficiency
Opis:
This paper presents the influence of cooling water regulation on power plant net efficiency. It was examined whether, for the non-nominal low-pressure turbine load, it is justified to reduce the cooling water pump load, and how it would affect the unit net efficiency. Calculations for two types of power units were carried out: with condensing and extraction-condensing turbine. The tested condensing power plant consists of three surface condensers. The calculation included four condensers’ connections set up on the cooling water side to check how the cooling water system pressure drop affects the net unit performance. The result has confirmed that implementing serial connection decreases net efficiency when cooling water flow regulation is used, but the mixed connection should be applied when pump load is not controlled. It was proved that the cooling water flow control gives a profit for both units. Net efficiency for combined heat and power plant can be improved by 0.1–0.5 pp, the gain is remarkable below 60% of the low-pressure turbine part load. Flow control implementation in the unit with condensing turbine water control gives a similar profit just below 80% of the turbine load. Next, an influence of the additional limitations of a cooling water system (minimal total pump head, cooling tower) affecting the feasibility of implementing the water control has been considered. Applying a multi-cell forced draft cooling tower does not have a significant impact on results, but when a natural draft cooling tower is used, the flow control range is strongly reduced.
Źródło:
Archives of Thermodynamics; 2022, 43, 1; 141--167
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermodynamic evaluation of a combined heat and power plant with carbon dioxide capture installation integrated with a gas turbine
Ocena termodynamiczna bloku elektrociepłowni współpracującej z instalacją wychwytu dwutlenku węgla przy jej integracji z turbiną gazową
Autorzy:
Bartela, Ł.
Skorek-Osikowska, A.
Rożek, M.
Powiązania:
https://bibliotekanauki.pl/articles/172973.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
analiza termodynamiczna
wychwyt CO2
turbina gazowa
elektrociepłownia
thermodynamic analysis
CO2 capture
gas turbine
CHP plant
Opis:
The paper presents the results of a thermodynamic analysis carried out for a coal-fired combined heat and power plant (CHP) working at supercritical parameters, integrated with an absorption based carbon dioxide capture installation. The power of a plant was set at 320 MW, and it was assumed that it produces heat in accordance with heat demand characteristics. It was also assumed that in order to obtain heat for the desorption unit, the plant was integrated with a gas turbine installation, at the outlet of which a recovery heat exchanger was mounted. For the analysis, the values of the characteristic quantities of the gas turbine were adopted. Power of the machine, in turn, depended on the heat demand of the desorption process. For the evaluation of the integration of a CHP plant, the defined in the paper average annual thermodynamic quantities and unit carbon dioxide emissions were used.
W artykule przedstawiono rezultaty analizy termodynamicznej przeprowadzonej dla bloku elektrociepłowni węglowej na parametry nadkrytyczne zintegrowanej z absorpcyjną instalacją wychwytu dwutlenku węgla. Moc elektrociepłowni określono na poziomie 320 MW, zakładając, że produkuje ona ciepło zgodnie z przyjętymi charakterystykami zapotrzebowania. Założono ponadto, iż dla potrzeb pozyskania ciepła dla procesu desorpcji blok elektrociepłowni zintegrowany został z instalacją turbiny gazowej, na wylocie której zabudowano wymiennik odzyskowy. Dla celów analizy określono odpowiednie wielkości charakteryzujące turbinę gazową. Moc maszyny z kolei zależała od ciepłochłonności procesu desorpcji. Przy ocenie integracji elektrociepłowni posłużono się zdefiniowanymi w pracy średniorocznymi wskaźnikami termodynamicznymi oraz emisją jednostkową dwutlenku węgla.
Źródło:
Archiwum Energetyki; 2012, 42, 2; 37-47
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of the Optimal Structure of Repowering a Metallurgical CHP Plant Fired with Technological Fuel Gases
Dobór optymalnej struktury elektrociepłowni gazowo-parowej opalanej hutniczymi gazami palnymi
Autorzy:
Ziębik, A.
Warzyc, M.
Gładysz, P.
Powiązania:
https://bibliotekanauki.pl/articles/352232.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
combined gas-and-steam cycle
metallurgical CHP plant
structure optimization
probabilistic approach
elektrociepłownia hutnicza
układ gazowo-parowy
optymalizacja struktury
podejście probabilistyczne
Opis:
CHP plants in ironworks are traditionally fired with low-calorific technological fuel gases and hard coal. Among metallurgical fuel gases blast-furnace gas (BFG) dominates. Minor shares of gaseous fuels are converter gas (LDG) and surpluses of coke-oven gas (COG). Metallurgical CHP plant repowering consists in adding a gas turbine to the existing traditional steam CHP plant. It has been assumed that the existing steam turbine and parts of double-fuel steam boilers can be used in modernized CHP plants. Such a system can be applied parallelly with the existing steam cycle, increasing the efficiency of utilizing the metallurgical fuel gases. The paper presents a method and the final results of analyzing the repowering of an existing metallurgical CHP plant fired with low-calorific technological fuel gases mixed with hard coal. The introduction of a gas turbine cycle results in a better effectiveness of the utilization of metallurgical fuel gases. Due to the probabilistic character of the input data (e.g. the duration curve of availability of the chemical energy of blast-furnace gas for CHP plant, the duration curve of ambient temperature) the Monte Carlo method has been applied in order to choose the optimal structure of the gas-and-steam combined cycle CHP unit, using the Gate Cycle software. In order to simplify the optimizing calculation, the described analysis has also been performed basing on the average value of availability of the chemical energy of blast-furnace gas. The fundamental values of optimization differ only slightly from the results of the probabilistic model. The results obtained by means of probabilistic and average input data have been compared using new information and a model applying average input data. The new software Thermoflex has been used. The comparison confirmed that in the choice of the power rating of the gas turbine based on both computer programs the results are similar.
Tradycyjnie elektrociepłownie hutnicze są opalane niskokalorycznymi palnymi gazami technologicznymi w mieszaninie z pyłem węgla kamiennego. W mieszaninie gazów dominujący jest udział gazu wielkopiecowego. Znacznie mniejsze są udziały gazu koksowniczego i konwertorowego. Modernizacja elektrociepłowni hutniczej (tzw. repowering) polega na dobudowaniu do istniejącej struktury członu gazowego. W analizie założono możliwość wykorzystania istniejących turbin parowych oraz części dwupaliwowych kotłów parowych. Układ gazowo-parowy zostanie połączony równolegle z istniejącym obiegiem parowym, zwiększając tym samym efektywność energetyczną wykorzystania niskokalorycznych gazów hutniczych. W artykule zaprezentowano metodologię oraz wyniki końcowe przeprowadzonej analizy modernizacji istniejącej elektro- ciepłowni hutniczej opalanej niskokalorycznymi gazami hutniczymi w mieszance z pyłem węgla kamiennego. Bazowano przy tym na zbiorze danych wejściowych z lat 1996-2000. Z uwagi na probabilistyczny charakter danych wejściowych (min. wykres uporządkowany dostępności energii chemicznej gazu wielkopiecowego oraz wykres uporządkowany temperatury zewnętrznej) wykorzystano metodę Monte Carlo w celu doboru optymalnej struktury kombinowanego gazowo-parowego układu elektrocie- płowni wykorzystując do tego oprogramowanie Gate Cycle. Obliczenia optymalizacyjne zostały również przeprowadzone w oparciu o uśrednioną wartość strumienia energii chemicznej gazu wielkopiecowego dostępnego dla elektrociepłowni. Wyniki obliczeń podstawowych parametrów z tej analizy różnią się w nieznacznym stopniu od wyników uzyskanych za pomocą modelu probabilistycznego. Wyniki uzyskane zarówno z metody probabilistycznej, jak i bazującej na wartościach średnich danych wejściowych zostały porównane z rezultatami obliczeń w oparciu o nowy zestaw danych (lata 2005-2008), jak również nowy model utworzony w programie Thermotlex oraz Engineering Equation Solver. Obliczenia zostały przeprowadzone w oparciu o uśredniony strumień energii chemicznej gazu wielkopiecowego dostępnego dla elektrociepłowni. Zastosowane do doboru struktury modernizowanej elektrociepłowni hutniczej programy komputerowe Gate Cycle i Thermoflex dały zbliżone rezultaty.
Źródło:
Archives of Metallurgy and Materials; 2014, 59, 1; 105-116
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of supercritical coal-fired combined heat and power plant integrated with membrane carbon capture and storage installation
Analiza nadkrytycznej elektrociepłowni węglowej zintegrowanej z membranową instalacją CCS
Autorzy:
Bartela, Ł.
Kotowicz, J.
Janusz-Szymańska, K.
Powiązania:
https://bibliotekanauki.pl/articles/172857.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
elektrociepłownia węglowa
blok CHP
membranowa instalacja CCS
coal power plant
CHP block
CCS membrane installation
Opis:
In the paper, the results of analysis of integrating chosen supercritical combined heat and power (CHP) unit with a membrane carbon capture and storage (CCS) installation are shown. As a way to improving the operation characteristics of such a system, the use of heat from cooling of permeate compressed in area of carbon capture installation for useful heat production is proposed. An additional source of heat is the cooling of carbon dioxide which is compressed for its preparation for transport to storage place. The considered use of cooling heat to useful heat production of leads to a reduction in steam consumption, and in consequence to an increase of steam turbine power. For two analyzed cases the influence of changing thermal load of unit on gross power and loads of heat exchangers is determined. The study involved the influence of assumed annual operation time of CHP unit on the basic thermodynamic characteristics: annual efficiency of electricity production, annual efficiency of heat production and annual overall efficiency. In conclusions, the paper highlighted the importance of the heat integration of CHP unit with CCS installation.
W artykule przedstawiono rezultaty analizy dotyczącej integracji wybranego nadkrytycznego bloku CHP z membranową instalacją CCS. Zaproponowano sposób na poprawę charakterystyk pracy takiego układu polegający na wykorzystaniu ciepła chłodzenia permeatu sprężanego w obrębie instalacji wychwytu dwutlenku węgla do produkcji ciepła użytkowego. Dodatkowym źródłem ciepła jest chłodzenie dwutlenku węgla sprężanego celem jego przygotowania do transportu do miejsca składowania. Rozpatrywane wykorzystanie ciepła chłodzenia jako ciepła grzewczego prowadzi do zmniejszenia poboru pary upustowej i w rezultacie do wzrostu mocy turbiny parowej. Dla dwóch analizowanych przypadków określono wpływ zmiany obciążeń cieplnych bloku na moc brutto oraz obciążenia poszczególnych wymienników ciepłowniczych. Badaniom poddano wpływ przyjętego czasu pracy elektrociepłowni w roku na podstawowe charakterystyki efektywności średniorocznej: średniorocznej sprawności wytwarzania energii elektrycznej, średniorocznej sprawności wytwarzania ciepła oraz średniorocznej sprawności ogólnej układu. W podsumowaniu pracy podkreślono duże znaczenie samej integracji bloku CHP z instalacją CCS po stronie cieplnej.
Źródło:
Archiwum Energetyki; 2011, 41, 3-4; 185-195
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies