Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Zieliński, S." wg kryterium: Autor


Wyświetlanie 1-7 z 7
Tytuł:
Is a Multi-Slider Interface Layout Responsible for a Stimulus Spacing Bias in the MUSHRA Test?
Autorzy:
Zieliński, S.
Powiązania:
https://bibliotekanauki.pl/articles/177197.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
audio quality assessment
subjective quality evaluation
listening tests
psychoacoustics
multi stimulus test with hidden reference and anchors
MUSHRA
Opis:
The multi-stimulus test with hidden reference and anchors (MUSHRA) is commonly used for subjective quality assessment of audio systems. Despite its wide acceptance in scientific and industrial sectors, the method is not free from bias. One possible source of bias in the MUSHRA method may be attributed to a graphical design of its user interface. This paper examines the hypothesis that replacement of the standard multi-slider layout with a single-slider version could reduce a stimulus spacing bias observed in the MUSHRA test. Contrary to the expectation, the aforementioned modification did not reduce the bias. This outcome formally supports the validity of using multiple sliders in the MUSHRA graphical interface.
Źródło:
Archives of Acoustics; 2015, 40, 4; 585-594
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Enhancing capabilities of Atomic Force Microscopy by tip motion harmonics analysis
Autorzy:
Babicz, S.
Smulko, J.
Zieliński, A.
Powiązania:
https://bibliotekanauki.pl/articles/199918.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
atomic force microscopy (AFM)
harmonics
van der Waals forces
Opis:
Motion of a tip used in an atomic force microscope can be described by the Lennard-Jones potential, approximated by the van der Waals force in a long-range interaction. Here we present a general framework of approximation of the tip motion by adding three terms of Taylor series what results in non-zero harmonics in an output signal. We have worked out a measurement system which allows recording of an excitation tip signal and its non-linear response. The first studies of spectrum showed that presence of the second and the third harmonics in cantilever vibrations may be observed and used as a new method of the investigated samples characterization.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 2; 535-539
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrasonic flow measurement with high resolution
Autorzy:
Grzelak, S.
Czoków, J.
Kowalski, M.
Zieliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/221448.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasonic flowmeter
time-to-digital converter
programmable logic device
time measurement
Opis:
The ultrasonic flowmeter which is described in this paper, measures the transit of time of an ultrasonic pulse. This device consists of two ultrasonic transducers and a high resolution time interval measurement module. An ultrasonic transducer emits a characteristic wave packet (transmit mode). When the transducer is in receive mode, a characteristic wave packet is formed and it is connected to the time interval measurement module inputs. The time interval measurement module allows registration of transit time differences of a few pulses in the packet. In practice, during a single measuring cycle a few time-stamps are registered. Moreover, the measurement process is also synchronous and, by applying the statistics, the time interval measurement uncertainty improves even in a single measurement. In this article, besides a detailed discussion on the principle of operation of the ultrasonic flowmeter implemented in the FPGA structure, also the test results are presented and discussed.
Źródło:
Metrology and Measurement Systems; 2014, 21, 2; 305-316
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
High resolution time-interval measurement systems applied to flow measurement
Autorzy:
Grzelak, S.
Kowalski, M.
Czoków, J.
Zieliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/221586.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
FPGA
time-to-digital converter
multi-segment delay line
carry chain
Opis:
The designing process of high resolution time interval measurement systems creates many problems that need to be eliminated. The problems are: the latch error, the nonlinearity conversion, the different duty cycle coefficient of the clock signal, and the clock signal jitter. Factors listed above affect the result of measurement. The FPGA (Field Programmable Gate Array) structure also imposes some restrictions, especially when a tapped delay line is constructed. The article describes the high resolution time-to-digital converter, implemented in a FPGA structure, and the types of errors that appear there. The method of minimization and processing of data to reduce the influence of errors on the measurement is also described.
Źródło:
Metrology and Measurement Systems; 2014, 21, 1; 77-84
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Simulation Model of the Radio Frequency MIMO-OFDM System
Autorzy:
Kowal, M.
Kubal, S.
Piotrowski, P.
Zieliński, R. J.
Powiązania:
https://bibliotekanauki.pl/articles/226276.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
MIMO-OFDM
Simulink
simulator
Opis:
The paper presents a simulation model of the radio frequency MIMO-OFDM system. The simulation model was made in Matlab Simulink environment. It contains the transmitter, the receiver and the telecommunication channel models. The telecommunication channel model consists of models used during development of technical documentation of IEEE 802.11n. Signals generated at the transmitter output are fully compatible with signals described in IEEE 802.11n [1]. Simulations are conducted on a radio frequency, so they can be compared with results of measurements of real systems.
Źródło:
International Journal of Electronics and Telecommunications; 2011, 57, 3; 323-328
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Operational characteristic of wireless WiMax and IEEE 802.11x systems in underground mine environments
Autorzy:
Kowal, M.
Kubal, S.
Piotrowski, P.
Zieliński, R. J.
Powiązania:
https://bibliotekanauki.pl/articles/227021.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
WLAN
WiMAX
throughput
delay
mine environment
Opis:
The paper presents research results pertaining to transmission parameters of wireless communication systems, based on WiMax and IEEE 802.11x radio interfaces. Research was performed in severe operating conditions of an underground mine - testing various parameters, such as: throughput, delays and maximum range.
Źródło:
International Journal of Electronics and Telecommunications; 2010, 56, 1; 81-86
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The silting-up prevention in the geothermal absorbent openings of Geothermal Energy Plant Pyrzyce
Autorzy:
Noga, B.
Marjanowski, J.
Biernat, H.
Kulik, S.
Zieliński, B.
Nalikowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/184948.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
energia geotermalna
absorpcja
geothermal energy
absorption openings
silting-up
soft acidising
super soft acidising
Opis:
The paper presents precipitation results from cold thermal water deposits that are the main cause of clogging in absorbent geothermal wells and borehole areas. As a result of physical and chemical analysis, laboratory tests and observation of the operation of a geothermal installation, a new method was developed to prevent the precipitation of sludge from cooled thermal water. The method being a modification of soft acidising was tentatively named as a super soft acidising method.
Źródło:
Chemical and Process Engineering; 2014, 35, 2; 205-216
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies