Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Zieliński, K. J." wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
Durability and narrow pore size distribution (PSD) of carbons fabricated from Salix Viminalis wood
Autorzy:
Łukaszewicz, J.P.
Zieliński, K.
Powiązania:
https://bibliotekanauki.pl/articles/184999.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
węgiel drzewny
Salix viminalis
wooden charcoal
carbon molecular sieves
specific surface
pore structure
Opis:
Microporous carbon molecular sieves of extremely narrow pore size distribution were obtained by carbonization of a novel raw material (Salix viminalis). The precursor is inexpensive and widely accessible. The pore capacity and specific surface area are upgradable by H3PO4 treatment without significant change of narrowed PSD. The dominating pore size indicates that these molecular sieves are a potential competitor to other nanoporous materials such as opened and purified carbon nanotubes.
Źródło:
Chemical and Process Engineering; 2011, 32, 3; 195-201
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microstructural Aspect of Long Term Service of the Austenitic TP347HFG Steel
Wpływ długotrwałej eksploatacji na mikrostrukturę stali TP347HFG
Autorzy:
Golański, G.
Lis, A. K.
Słania, J.
Zieliński, A.
Powiązania:
https://bibliotekanauki.pl/articles/352367.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
TP347HFG steel
microstructure
TEM
stal TP347HFG
mikrostruktura
Opis:
The paper presents the results of research on the microstructure of austenitic creep-resisting TP347HFG steel after longterm service. The tests of the microstructure were performed using SEM and TEM. The identification of precipitates was carried out using selective electron diffraction. It has been shown that long-term service mostly contributes to the processes of precipitation of secondary NbC carbides inside grains and M23C6 carbides on grain boundaries. In the microstructure of the examined steel, also the processes of polygonization and recrystallization of the matrix were revealed.
W pracy przedstawiono wyniki badań mikrostruktury austenitycznej, żarowytrzymałej stali TP347HFG po długotrwałej eksploatacji. Badania mikrostruktury przeprowadzono przy użyciu techniki SEM i TEM. Identyfikację wydzieleń wykonano wykorzystując selektywną dyfrakcję elektronów. Wykazano, że długotrwała eksploatacja badanej stali przyczyniła się głównie do procesów wydzielania: węglików wtórnych NbC wewnątrz ziaren oraz węglików M23C6 po granicach ziaren. Ujawniono również w mikrostrukturze badanej stali procesy poligonizacji i rekrystalizacji osnowy.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 4; 2901-2904
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of the annealing time after welding on the mechanical properties of welded joint of T91 steel
Autorzy:
Wojsyk, K.
Golański, G.
Jasak, J.
Słania, J.
Zieliński, A.
Urbańczyk, P.
Powiązania:
https://bibliotekanauki.pl/articles/351017.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
T91 steel
post welded heat treatment
mechanical properties
Opis:
The paper presents the results of research on the influence of the time of annealing after welding at the temperature of 750°C on the mechanical properties of a homogeneous welded joint of T91 steel. The welded joints were annealed at 750°C for 0.5; 1.0; 1.5 and 2.0 hours. The research scope included the basic study, i.e. the measurement of hardness, the test of impact energy, the static tensile test, bending test, as well as the accelerated creep test. The results of the tests of mechanical properties indicate the possibility of using shorter annealing times for thin-walled welded joints, and thus the possibility of savings as a result of flexible heat treatments.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 3; 1425-1430
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A hybrid (hydro-numerical) circulatory model: investigations of mechanical aortic valves and a numerical valve model
Autorzy:
Kozarski, M.
Suwalski, P.
Zieliński, K.
Górczyńska, K.
Szafron, B.
Pałko, K. J.
Smoczyński, R.
Darowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/202199.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
biological and mechanical heart valves
numerical heart valve
hybrid (hydro-numerical) circulatory model
voltage-controlled hydraulic pressure (flow) source
hydraulic input impedance
varying-elastance left ventricle
Opis:
In most cases of diseased heart valves, they can be repaired or replaced with biological or mechanical prostheses. Biological prostheses seem to be safer than mechanical ones and are applied with good clinical outcomes. Their disadvantage, when compared with mechanical valves, is durability. In the development and application of mechanical and biological heart valves, a significant role can be played by a Hybrid (Hydro-Numerical) Circulatory Model. The aim of this paper is to demonstrate the opportunities created by the hybrid model for investigations of mechanical heart valves and their computer models under conditions similar to those of the circulatory system. A diode-resistor numerical valve model and three different design mechanical aortic valves were tested. To perform their investigations, computer applications were developed under RT LabView to be run on a PC. Static and dynamic characteristics of the valves were measured and registered - pressure in the numerical time-varying elastance left ventricle (pLV), in the aorta (pas) and flow (f), proving, among other factors, that 1) time delay of pas with respect to pLV is mainly related to the valve’s opening time, and 2) the valves of substantially different designs tested under identical hydrodynamic conditions reveal nearly the same dynamic performance.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2015, 63, 3; 605-612
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new hybrid (hydro-numerical) model of the circulatory system
Autorzy:
Darowski, M.
Kozarski, M.
Ferrari, G.
Zieliński, K.
Górczyńska, K.
Szczepanowski, A.
Pałko, K. J.
Fresiello, L.
Di Molfetta, A.
Powiązania:
https://bibliotekanauki.pl/articles/199804.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
lumped parameter circulatory model
hybrid hydro-numerical models
impedance transformers
LVAD assistance
variable elastance
Opis:
The paper presents a hybrid (hydro-numerical) circulatory model built to be used as a complementary tool for clinical purposes. It was developed at the Institute of Biocybernetics and Biomedical Engineering - Polish Academy of Sciences (Poland) in co-operation with the Institute of Clinical Physiology - National Council of Research (Italy). Main advantages of the model are: 1) high accuracy and repeatability of parameters setting, characteristic of numerical solutions, 2) maximum flexibility achieved by implementing the largest possible number of the model’s elements in the numerical way, 3) ability to test mechanical heart assist devices provided by special computer applications; in the model two physically different signal environments - numerical and hydraulic - are connected by special impedance transformers interfacing physical and numerical parts of the model; 4) eliminating flowmeters, as the voltage controlled flow sources embedded in the system provide information on flows. In vitro tests were performed to evaluate the circulatory model: a) modelling and simulation of physiological and pathological states parameters vs. left ventricular end-systolic elastance (Emax l) and rest volume (Vol) variations, b) testing the effect of LVAD counterpulsation on circulatory hemodynamics and ventricular energetics; it resulted in the increase of total cardiac output (COLV tot) from pathological value 3.8 to 5.4 l·min−1, mean aortic pressure mPas from 67.8 to 96.1 mmHg and in the decrease of left atrial pressure mPla from 15.7 to 7.7 mmHg and External Work nEW by 37.5%. The model was verified based on literature data.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 4; 993-1003
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies