Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Li, Ping" wg kryterium: Autor


Wyświetlanie 1-10 z 10
Tytuł:
Battery/super-capacitor HESS applied in DC microgrid
Autorzy:
Zhang, Zhen
Baoge Zhang, Baoge
Wang, Donghao
Li, Ping
Rong, Yao
Powiązania:
https://bibliotekanauki.pl/articles/140713.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
battery
bi-directional DC/DC converter
HESS
super-capacitor
voltage closedloop
Opis:
Energy storage technology (EST) is an effective way to improve the power quality of renewable energy generation (such as solar energy and wind energy), but a single energy storage system (ESS) is difficult to meet the demand for the safe operation of the grid. According to the structure and operation characteristics of the existing battery/super-capacitor hybrid energy storage system (HESS), a battery/super-capacitor HESS is proposed. The working principle and three working modes (the super-capacitor pre-charging cold standby mode, the boost mode and buck mode) of the HESS are analyzed in detail. The state equations of the boost mode and buck mode are derived. The state space average method is used to establish the small signal equivalent model under the buck/boost mode. Moreover, the charge and discharge control strategy of the HESS is obtained by combining the voltage closed-loop control. The simulation model is built in Matlab/Simulink to verify the effectiveness of the proposed HESS and its control strategy. The results show that the HESS and its control strategy can ensure the DC bus voltage has good stability and superior anti-interference, and it can simultaneously provide large current, increase the battery life, and improve the technical economy of energy storage.
Źródło:
Archives of Electrical Engineering; 2020, 69, 2; 379-388
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on emergency DC power support coordinated control for hybrid multi-infeed HVDC system
Autorzy:
Li, Congshan
Li, Yikai
Guo, Jian
He, Ping
Powiązania:
https://bibliotekanauki.pl/articles/140422.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
additional controllers
coordinated control
EDCPS
hybrid multi-infeed HVDC system
HVDC
Opis:
Based on the respective characteristics of line-commutated converter highvoltage direct current (LCC-HVDC) and voltage-source converter high voltage direct current (VSC-HVDC), two additional emergency DC power support (EDCPS) controllers are designed, respectively. In addition a coordinated control strategy based on a hybrid multi-infeed HVDC system for EDCPS is proposed. Considering the difference in system recovery between LCC-HVDC and VSC-HVDC in EDCPS, according to the magnitude of the amount of potential power loss, the LCC-HVDC and VSC-HVDC priority issues of boosting power for EDCPS are discussed in detail. Finally, a hybrid three-infeed HVDC that consists of two parallel LCC-HVDCs and one VSC-HVDC that is built in PSCAD/EMTDC are simulated. The effectiveness of the proposed approach is verified based on this hybrid three-infeed HVDC system.
Źródło:
Archives of Electrical Engineering; 2020, 69, 1; 5-21
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improvement of damping characteristics and index evaluation of a wind-PV-thermal-bundled power transmission system by combining PSS and SSSC
Autorzy:
He, Ping
Wu, Xinxin
Li, Congshan
Zheng, Mingming
Li, Zhao
Powiązania:
https://bibliotekanauki.pl/articles/140453.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
damping characteristics
eigenvalue analysis
power system stabilizer
wind-PV-thermal-bundled power system
Opis:
The grid integration of large-scale wind and solar energy affects the power flow of wind-PV-thermal-bundled power transmission systems and may introduce an unpredicted threat to the power system’s small signal stability. Meanwhile, a power system stabilizer (PSS) and static synchronous series compensator (SSSC) play an important role in improving the static and dynamic stability of the system. Based on this scenario and in view of the actual engineering requirements, the framework of wind-PV-thermal-bundled power transmitted by an AC/DC system with the PSS and SSSC is established considering the fluctuation of wind and photovoltaic power output and the characteristics of the PSS and SSSC. Afterwards, the situation model is constructed in the IEEE 2-area 4-unit system, and the influence of the PSS and SSSC on the system stability under different operating conditions is analyzed in detail through eigenvalue analysis and time-domain simulation. Finally, an index named the gain rate is defined to describe the improvement of the stability limitations of various wind-PV-thermal operating conditions with the PSS and SSSC. The results indicate (K) that the damping characteristics, dynamic stability and stability limitations for various wind-PV-thermal operating conditions of the wind-PV-thermal-bundled power transmission system can be significantly improved by the interaction of the PSS and SSSC.
Źródło:
Archives of Electrical Engineering; 2020, 69, 3; 705-721
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design and computation of a lightning protection system in an urban 110 kV substation
Autorzy:
Taha, Mohammed Ibrahim
Li, Lin
Wang, Ping
Powiązania:
https://bibliotekanauki.pl/articles/140973.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
CDEGS software
fast Fourier transform (FFT)
IEC 62305-3
lightning protection system (LPS)
NFPA 780 level 1
Opis:
A lightning protection system (LPS) of an urban 110 kV substation is designed and analysed according to NFPA 780 and IEC 62305-3 standards. The analysis of the LPS is established on the value of risk assessment. The total area of the plant is described by one soil layer with uniform resistivity. This study aims to improve the understanding of an unexpected manner of the grounding system beneath lightning currents by clarifying the basic concepts of the lightning protection level and the new design procedure in this paper was clarified according to NFPA-780 level 1 for a lightning protection system. The program is integrated with the CDEGS software, which provides effective geometrical modeling with object and result visualization. Furthermore, module and automated fast Fourier transform (FFT) is implemented in this study to simulate electromagnetic fields in the time and frequency domains. These current values are compared to the desired protection levels within the standards. The study results show that for the improved protection of the system against lightning, the total power grid must be considered as a source of improvement for studying shielding influence and the protection levels provided inside this substation.
Źródło:
Archives of Electrical Engineering; 2020, 69, 3; 723-738
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamic interactions stability analysis of hybrid renewable energy system with SSSC
Autorzy:
He, Ping
Qi, Pan
Ji, Yuqi
Li, Zhao
Powiązania:
https://bibliotekanauki.pl/articles/1841302.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
damping characteristics
dynamic interaction analysis
eigenvalue analysis
hybrid renewable energy system
SSSC
charakterystyka tłumienia
dynamiczna analiza interakcji
analiza wartości własnej
hybrydowy system energii odnawialnej
Opis:
The static series synchronous compensator (SSSC) has demonstrated its capability in providing voltage support and improving power system stability. The objective of this paper is to analyze the dynamic interaction stability mechanism of a hybrid renewable energy system connected with doubly-fed induction generators (DFIGs) and solid oxide fuel cell (SOFC) energy with the SSSC. For this purpose, a linearized mathematical model of this modified hybrid single-machine infinite-bus (SMIB) power system is developed to analyze the physical mechanism of the SSSC in suppressing oscillations and the influence on the dynamic stability characteristics of synchronization. Typical impacting factors such as the series compensation level, the SOFC penetration and tie-line power are considered in the SMIB and two-area systems. The impact of dynamic interactions on enhancing damping characteristics and improving transient performance of the studied systems is demonstrated using eigenvalue analysis and dynamic time-domain simulations, which validates the validity of the proposed physical mechanism simultaneously.
Źródło:
Archives of Electrical Engineering; 2021, 70, 2; 445-462
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An approach to suppress low-frequency oscillation in the hybrid multi-Infeed HVDC of mixed H2/H∞ robust-based control theory
Autorzy:
Li, Congshan
Liu, Yan
Li, Yikai
He, Ping
Fang, Yan
Sheng, Tingyu
Powiązania:
https://bibliotekanauki.pl/articles/2042784.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
additional damping controller
CSP
HMIDC
LFO
mixed 2/∞ control
TLS-ESPRIT
Opis:
A hybrid multi-infeed HVDC (HMIDC) system is composed of line-commutated converter-based high-voltage direct current (LCC-HVDC) and voltage-source converterbased high-voltage direct current (VSC-HVDC), whose receiving ends have electrical coupling. To solve the problem of low-frequency oscillation (LFO) caused by insufficient damping in the HMIDC system, according to the multi-objective mixed 2/∞ output feedback control theory with regional pole assignment, an additional robust damping controller is designed in this paper, which not only has good robustness, but also has strong adaptability to the change of system operation mode. In the paper, the related oscillation modes and transfer function of the controlled plant are obtained, which are identified by the total least squares estimation of signal parameters via rotary invariance technology (TLS-ESPRIT). In addition, the control-sensitive point (CSP) for suppressing LFO based on the small disturbance test method is determined, which is suitable for determining the installation position of the controller. The results show that the control sensitivity factor of VSC-HVDC is greater than that of LCC-HVDC so that adding an additional damping controller to VSC-HVDC is better than LCC-HVDC in suppressing the LFO of HMIDC. Finally, a hybrid double infeed DC transmission system with three receiving terminals is built on PSCAD/EMTDC where the time-domain simulations are performed to verify the correctness of the CSP selection and the effectiveness of the controller.
Źródło:
Archives of Electrical Engineering; 2022, 71, 1; 109-124
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
HVDC auxiliary emergency power control strategy for power disturbance in two different positions of AC/DC interconnection system
Autorzy:
Li, Congshan
He, Ping
Wang, Youyi
Ji, Yuyi
Yang, Cunxiang
Powiązania:
https://bibliotekanauki.pl/articles/141502.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
unbalanced power
emergency control
power angle stability
frequency stability
control logic
Opis:
High voltage direct current (HVDC) emergency control can significantly improve the transient stability of an AC/DC interconnected power grid, and is an important measure to reduce the amount of generator and load shedding when the system fails. For the AC/DC interconnected power grid, according to the location of failure, disturbances can be classified into two categories: 1) interconnected system tie-line faults, which will cause the power unbalance at both ends of the AC system, as a result of the generator rotor acceleration at the sending-end grid and the generator rotor deceleration at the receiving-end grid; 2) AC system internal faults, due to the isolation effect of the DC system, only the rotor of the generator in the disturbed area changes, which has little impact on the other end of the grid. In view of the above two different locations of disturbance, auxiliary power and frequency combination control as well as a switch strategy, are proposed in this paper. A four-machine two-area transmission system and a multi-machine AC/DC parallel transmission system were built on the PSCAD platform. The simulation results verify the effectiveness of the proposed control strategy.
Źródło:
Archives of Electrical Engineering; 2019, 68, 2; 245-263
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Continuous Growth of Bulk Si by Temperature Gradient Zone Melting Method
Autorzy:
Li, Jiayan
Wang, Liang
Hao, Jianjie
Ni, Ping
Tan, Yi
Powiązania:
https://bibliotekanauki.pl/articles/356541.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bulk Si
TGZM
Si-Al alloy
growth rate
impurities
Opis:
Temperature gradient zone melting (TGZM) method was used to obtain bulk Si continuously for the efficient separation and purification of primary Si from the Si-Al alloy in this work. The effects of alloy thickness, temperature gradient and holding time in TGZM purification technology were investigated. Finally, the continuous growth of bulk Si without eutectic inclusions was obtained. The results showed that the growth rate of bulk Si was independent of the liquid zone thickness. When the temperature gradient was changed from 2.48 K/mm to 3.97 K/mm, the growth rate of bulk Si was enhanced from 7.9×10-5 mm/s to 2.47×10-4 mm/s, which was increased by about 3 times. The bulk Si could grow continuously and the growth rate was decreased with the increase of holding time from 1 h to 5 h. Meanwhile, low refining temperature was beneficial to the removal of impurities. With a precipitation temperature of 1460 K and a temperature gradient of 2.48 K/mm, the removal rates of Fe, P and B were 99.8%, 94.0% and 63.6%, respectively.
Źródło:
Archives of Metallurgy and Materials; 2019, 64, 1; 271-278
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electromechanical transient modeling of energy storage based on virtual synchronous machine technology
Autorzy:
Cui, Juntao
Li, Zhao
He, Ping
Gong, Zhijie
Dong, Jie
Powiązania:
https://bibliotekanauki.pl/articles/2135738.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
battery energy storage system
electromechanical transient model
virtual synchronous machine
Opis:
This paper proposes an electromechanical transient method to build a battery energy storage system-based virtual synchronous generator model, suitable for a large-scale grid. This model consists of virtual synchronous generator control, system limitation and the model interface. The equations of a second-order synchronous machine, the characteristics of charging/discharging power, state of charge, operating efficiency, dead band and inverter limits are also considered. By equipping the energy storage converter into an approximate synchronous voltage source with an excitation system and speed regulation system, the necessary inertia and damping characteristics are provided for the renewable energy power system with low inertia and weak damping. Based on the node current injection method by the power system analysis software package (PSASP), the control model is built to study the influence of different energy storage systems. A study on the impact of renewable energy unit fluctuation on frequency and the active power of the IEEE 4-machine 2-area system is selected for simulation verification. Through reasonable control and flexible allocation of energy storage plants, a stable and friendly frequency environment can be created for power systems with high-penetration renewable energy.
Źródło:
Archives of Electrical Engineering; 2022, 71, 3; 581--599
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on Distribution and Morphology of Primary Si Under the Effect of Direct Current
Autorzy:
Li, Jiayan
Njuguna, Benson Kihono
Ni, Ping
Wang, Liang
Tan, Yi
Powiązania:
https://bibliotekanauki.pl/articles/2049663.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
silicon source
direct current
Joule heating
Si morphology
Fe impurity
Opis:
A source of pure silicon was added into an alloy refining system during a refining process with the application of a direct electric current. The effect of the temperature difference between the graphite electrodes and the alloy was decreased. The temperature increase value (ΔT) of the Al-28.51wt.%Si alloy sample caused by Joule heating was calculated by weighing the mass of primary silicon. When the current density was 5.0×105A/m2, the overall temperature increase in the alloy was about 90°C regardless of the alloy composition. Adequate silicon atoms recorded the footprint of the electric current in the alloy melt. The flow convection generated by the electric current in the melt during the solidification process resulted in the refinement of primary silicon. The Fe impurity content in alloy refining without the electric current density was 2.16 ppm. However, it decreased to 1.27 ppmw with the application of an electric current density of 5.0×105A/m2.
Źródło:
Archives of Metallurgy and Materials; 2021, 66, 2; 367-372
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-10 z 10

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies