Tytuł:
Thermodynamic analysis of a new dual evaporator CO2 transcritical refrigeration cycle
Autorzy:
Abdellaoui, E. Y.
Kairouani, L. K.
Powiązania:
https://bibliotekanauki.pl/articles/240198.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
CO2
energy
refrigeration
ejector
exergy
energia
chłodzenie
ejektor
egzergia
Opis:
In this work, a new dual-evaporator CO2 transcritical refrigeration cycle with two ejectors is proposed. In this new system, we proposed to recover the lost energy of condensation coming off the gas cooler and operate the refrigeration cycle ejector free and enhance the system performance and obtain dual-temperature refrigeration simultaneously. The effects of some key parameters on the thermodynamic performance of the modified cycle are theoretically investigated based on energetic and exergetic analysis. The simulation results for the modified cycle indicate more effective system performance improvement than the single ejector in the CO2 vapor compression cycle using ejector as an expander ranging up to 46%. The exergetic analysis for this system is made. The performance characteristics of the proposed cycle show its promise in dual-evaporator refrigeration system.
Źródło:
Archives of Thermodynamics; 2017, 38, 1; 39-62
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance analysis of a new combined organic Rankine cycle and vapor compression cycle for power and refrigeration cogeneration
Autorzy:
Toujani, N.
Bouaziz, N.
Chrigui, M.
Kairouani, L.
Powiązania:
https://bibliotekanauki.pl/articles/175539.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
organic Rankine cycle
cogeneration
vapor compression cycle
new combined
Opis:
Organic Rankine cycle (ORC) is considered the most used technology in low temperature heat recovery units for cogeneration (electricity and cold). In this study, the effect of the operating parameters, in particular the condensation and the vaporization temperatures on the performance of the cycle are analyzed. In addition, we developed a new combination of organic Rankine cycle and vapor compresion cycle systems to make cogeneration with a negative cold (-10–0◦C), as well with a positive cold (0–10◦C). Three configurations are examined and studied in terms of energy efficiency, namely the performance of each configuration including net power, refrigeration capacity and overall efficiency, the thermal efficiency for ORC and the coefficient of performance for VCC. The used working fluids are n-hexane for the ORC and R600 for the VCC. We also try to apply this new system to have the cogeneration with congelation temperatures. The results show that, for cogeneration with negative cold, among the three configurations that we have developed, the cycle with recovery is preferable in which it has a better energy performance. For a hot spring of 1000 kW, this cycle can provide simultaneously, a maximum net work of 17 kW and a maximum net cooling capacity of 160 kW and an overall coefficient of the order of 0.3. For the production of positive cold, among the three configurations that we have developed, the basic cycle (without recovery) is the most suitable. With the same source of heat a maximum net work of 65 kW and a net cooling capacity in the order of 1000 kW with a global coefficient in the order of 1.05 is obtained. Our system is not only limited to be exploited for a temperature range between -10 ◦C and 10 ◦C, but can also be used with other fluids for lower temperatures (congelation temperatures).
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2018, 140; 39-81
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hybrid cascade refrigeration systems for refrigeration and heating
Autorzy:
Megdouli, K.
Ezzaalouni, Y.
Nahdi, E.
Mhimid, A.
Kairouani, L.
Powiązania:
https://bibliotekanauki.pl/articles/240448.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ejector cycle
heat pump
comparison
refrigerant
coefficient of performance
irreversibility
exergy loss
second law efficiency
pompa ciepła
porównanie
czynnik chłodniczy
współczynnik
efektywność
nieodwracalność
Opis:
In this study a cooling ejector cycle coupled to a compression heat pump is analyzed for simultaneous cooling and heating applications. In this work, the influence of the thermodynamic parameters and fluid nature on the performances of the hybrid system is studied. The results obtained show that this system presents interesting performances. The comparison of the system performances with hydrofluorocarbons (HFC) and natural fluids is made. The theoretical results show that the a low temperature refrigerant R32 gives the best performance.
Źródło:
Archives of Thermodynamics; 2018, 39, 2; 73-95
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies