Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Gawlikowski, M." wg kryterium: Autor


Wyświetlanie 1-6 z 6
Tytuł:
The influence of limited dynamic response of the indicator detector in a Swan-Ganz catheter on the overestimation of cardiac output measurement by means of thermodilution
Autorzy:
Gawlikowski, M.
Pustelny, T.
Powiązania:
https://bibliotekanauki.pl/articles/221141.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cardiac output measurement
thermodilution method
Swan-Ganz catheter
Opis:
Nowadays the "gold clinical standard" of hemodynamics diagnostic and cardiac output measurements is pulmonary artery catheterization by means of the Swan-Ganz catheter and thermodilution. The method itself is sensitive to numerous disturbances which cause inaccurate results. One of the well-known disadvantages of thermodilution is the overestimation of results at low values of cardiac output. This effect may concern the limited slew rate of the thermoelement mounted at the tip of the catheter. In this paper the relationship between the dynamic response of the thermoelement and the uncertainty of cardiac output measurements by means of thermodilution has been investigated theoretically and experimentally.
Źródło:
Metrology and Measurement Systems; 2012, 19, 4; 751-758
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of actual accuracy in cardiac output measurements by means of thermodilution
Autorzy:
Gawlikowski, M.
Pustelny, T.
Powiązania:
https://bibliotekanauki.pl/articles/201601.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cardiac output
hemodynamics monitoring
thermodilution
Opis:
The essential examination in hemodynamic monitoring of the patient is the cardiac output (CO) measurement. Nowadays, in clinical practice the most popular method is indicator dilution, particularly thermodilution. It is realized by applying the Swan-Ganz catheter and observing changes of the indicator concentration. This method is sensitive to many factors and the obtained results should be treated cautiously. The paper presents theoretical and experimental studies of metrological phenomena in CO measurements by means of thermodilution, paying special attention to medical aspects of the measurements. It has been pointed out that the actual unreliability of the mentioned method reaches values from 20% to 45%, which is in opposition to the technical data of patient's monitors (typical accuracy about 5%).
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2012, 60, 3; 581-587
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Acoustic System of Determining the Instantaneous Volume of the Blood Part of the Ventricular Assist Device POLVAD-EXT
Autorzy:
Konieczny, G.
Pustelny, T.
Opilski, Z.
Gawlikowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/176599.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic Helmholtz’s
resonator
blood volume estimation
VAD
ventricular assist device
Opis:
The paper presents the results of investigations concerning the noninvasive method of estimating the actual volume of the blood chamber of the POLVAD-EXT type ventricular assist device (VAD) during its operation. The proposed method is based on the principle of Helmholtz’s acoustic resonance. Both the theory, main stages of the development of the measurement method as well as the practical implementation of the proposed method in the physical model of the POLVAD-EXT device are dealt with. The paper contains the results of static measurements by means of the proposed method (conducted at the Department of Optoelectronics, Silesian University of Technology) as well as the dynamic measurements taken at the Foundation of Cardiac Surgery Development (Zabrze, Poland) with the professional model of the human cardiovascular system. The results of these measurements prove that the proposed method allows to estimate the actual blood chamber volume with uncertainties below 10%.
Źródło:
Archives of Acoustics; 2014, 39, 4; 541-548
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Theoretical and model analysis of the unreliability of cardiac output measurement by means of the thermodilution method
Autorzy:
Gawlikowski, M.
Pustelny, T.
Przywara-Chowaniec, B.
Nowak-Gawlikowska, J.
Powiązania:
https://bibliotekanauki.pl/articles/200095.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cardiac output measurement
thermodilution method
Opis:
Thermodilution is the clinically most often applied method of cardiac output measurements. This method is based on thermal indicator (iced isotonic salt solution) variation measurements by a Swan-Ganz catheter located inside the pulmonary artery. The unreliability of thermodilution should be estimated theoretically because of the lack of references. In this paper an attempt has been made to estimate theoretically the unreliability of thermodilution cardiac output measurements.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2011, 59, 4; 435-439
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Noninvasive acoustic blood volume measurement system for the POLVAD prosthesis
Autorzy:
Opilski, Z.
Konieczny, G.
Pustelny, T.
Gacek, A.
Kustosz, R.
Gawlikowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/200093.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heart prosthesis
medical acoustics
blood volume measurement system
Opis:
The following paper presents researches concerning a noninvasive real-time blood volume measurement system applied in POLVAD prosthesis. The system is based on the acoustic Helmholtz resonator principle. The basis of the measurement method, followed by the preliminary tests of the possibility of incorporating the Helmholtz resonance idea into the POLVAD prosthesis is shown. The paper includes the actual measurement system construction and test results, both static and dynamic obtained at the Foundation for Cardiac Surgery Development in Zabrze, Poland. Conclusions and future plans are presented too.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2011, 59, 4; 429-433
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Tin Coatings Utilisation As Blood Contact Surface Modification In Implantable Rotary Left Ventricle Assist Device ReligaHeart Rot
Wykorzystanie powłok TiN jako zmodyfikowanych powierzchni kontaktowych w implantowalnej rotacyjnej komorze wspomagania serca ReligaHeart ROT
Autorzy:
Kustosz, R.
Altyntsev, I.
Darlak, M.
Wierzchoń, T.
Tarnowski, M.
Gawlikowski, M.
Gonsior, M.
Kościelniak-Ziemniak, M.
Powiązania:
https://bibliotekanauki.pl/articles/355709.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
titanium nitride layers
athrombogenic coatings
implantable rotary pump
heart assistance
warstwy azotku tytanu
zakrzepy
wszczepialna pompa rotacyjna
serce
Opis:
Constructions of the mechanical-bearingless centrifugal blood pumps utilize different types of non-contact physical bearings, which allows to balance the forces that have an impact on the pump impeller, stabilizing its position in the pump house without wall contact. The paper presents investigations of the hybrid (passive magnetic bearings and hydrodynamic bearings) suspension system for the centrifugal blood pump. Numerical simulations were used to evaluate the hydrodynamic bearing lifting force and magnetic bearing forces interaction. An important aspect of rotor suspension system design was the nominal gap in hydrodynamic bearing area in order to reduce the blood damage risk in this region. The analyses results confirmed that for a small diameter centrifugal pump, the nominal operating hydrodynamic bearing gap could be established within the range from 0.033 to 0.072 mm.
Konstrukcje pomp odśrodkowych pozbawionych łożysk mechanicznych wykorzystują różne rodzaje bezkontaktowych łożysk fizycznych, które pozwalają balansować siły oddziałujące na wirnik pompy, stabilizując jego pozycję w obudowie pompy bez kontaktu ze ścianami. Artykuł przedstawia badania hybrydowego (pasywne łożyska magnetyczne i łożyska hydrodynamiczne) systemu zawieszenia wirnika dla odśrodkowej pompy krwi. Symulacji numerycznych użyto dla zbadania siły unoszącej łożyska hydrodynamicznego oraz reakcji łożysk magnetycznych. Ważnym aspektem konstrukcji systemu zawieszenia wirnika było zwiększenie nominalnego prześwitu w obszarze łożyska hydrodynamicznego, aby zredukować ryzyko uszkadzania krwi w tym rejonie. Wyniki analiz potwierdziły możliwość wyznaczenia nominalnego prześwitu w łożysku hydrodynamicznym, dla pomp odśrodkowych małej średnicy, w przedziale od 0,033 do 0,072 mm.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 3; 2253-2260
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies