Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "water loss" wg kryterium: Wszystkie pola


Wyświetlanie 1-8 z 8
Tytuł:
Influence of horse breed on transepidermal water loss
Autorzy:
Szczepanik, M.P.
Wilkolek, P.M.
Adamek, L.R.
Pluta, M.
Golynski, M.
Sitkowski, W.
Kalisz, G.
Taszkun, I.
Pomorski, Z.J.K.
Powiązania:
https://bibliotekanauki.pl/articles/30727.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Opis:
Non-invasive methods of skin condition assessment include, among others, the evaluation of transepidermal water loss (TEWL). The aim of the study was to examine whether TEWL values depend on horse breed. The study was conducted on four breeds: “Felin” ponies (FP) (n=16), Polish koniks (PK) (n=15), Polish cold-blooded horses (PcbH) (n=11) and Wielkopolska horses (WH) (n=12). It was found that horse breed influences TEWL values. In the neck region, statistically significant differences were found between PK and FP (p=0.006), and PK and WH (p=0.0005). In the lumbar region, there were statistically significant differences between FP and PK (p=0.0009), FP and PcbH (p=0.0016) as well as between PK and WH (p=0.000037), and PcbH and WH (p=0.0006). In the inguinal region statistically significant differences were found between FP and PK (p=0.0003), FP and PcbH (p=0.0005), PK and WH (p=0.009) and PcbH and WH (p=0.006). In the lip region statistically significant differences were observed between FP and PK (p=0.013) as well as between PK and PcbH (p=0.029) and PK and WH (p=0.009). In the examination of TEWL animal breed should be taken into consideration. The non-significant differences found in three of the examined body regions may suggest that these regions are the most adequate for TEWL assessment.
Źródło:
Polish Journal of Veterinary Sciences; 2016, 19, 4
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of hair clipping on transepidermal water loss values in horses: a pilot study
Autorzy:
Gołyński, M.
Szczepanik, M.P.
Wilkołek, P.M.
Adamek, Ł.R.
Sitkowski, W.
Taszkun, I.
Powiązania:
https://bibliotekanauki.pl/articles/2087774.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
horses
transepidermal water loss
clipping
Źródło:
Polish Journal of Veterinary Sciences; 2018, 21, 1; 35-38
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transepidermal water loss and skin hydration in healthy cats and cats with non-flea non-food hypersensitivity dermatitis (NFNFHD)
Autorzy:
Szczepanik, M.P.
Wilkołek, P.M.
Adamek, Ł.R.
Kalisz, G.
Gołyński, M.
Sitkowski, W.
Taszkun, I.
Powiązania:
https://bibliotekanauki.pl/articles/2087561.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cats
atopic dermatitis
transepidermal water loss
skin hydration
Źródło:
Polish Journal of Veterinary Sciences; 2019, 2; 237-242
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The examination of biophysical parameters of skin (transepidermal water loss, skin hydration and pH value) in different body regions of ponies
Autorzy:
Szczepanik, M.P.
Wilkolek, P.M.
Pluta, M.
Adamek, L.R.
Pomorski, Z.J.H.
Powiązania:
https://bibliotekanauki.pl/articles/31537.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
biophysical parameter
skin
water loss
hydration
pH value
body region
pony
horse
Opis:
The purpose of this study was to evaluate transepidermal water loss, skin hydration and skin pH in normal ponies. Sixteen ponies of both sexes were examined in the study. Measurements were taken from seven different sites: the neck region, the shoulder, thorax, lumbar, inguinal, lip region and the auricle. In each of the regions transepidermal water loss (TEWL), skin hydration and skin pH were measured. For transepidermal water loss, the lowest values were observed in the lumbar region (9.71g/hm2), while the highest values were observed in the lip region (22.35 g/hm2). In the case of skin hydration the lowest values were observed for the thorax region (2.13 CU), and the highest for the lip region (41.81 CU). For skin pH, the lowest results were obtained in the lumbar region (6.93), and the highest in the lip region (7.96).
Źródło:
Polish Journal of Veterinary Sciences; 2012, 15, 3
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The examination of biophysical skin parameters (transepidermal water loss, skin hydration and pH value) in different body regions in Polish ponies
Autorzy:
Szczepanik, M P
Wilkolek, P M
Pluta, M.
Adamek, L R
Golynski, M
Pomorski, Z J H
Sitkowski, W
Powiązania:
https://bibliotekanauki.pl/articles/31823.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Opis:
The purpose of this study was to evaluate transepidermal water loss, skin hydration and skin pH in normal polish ponies. Twelve ponies of both sexes were examined in the study. Measurements were taken from seven different sites: the neck region, the shoulder, thorax, lumbar, inguinal, lip region and the pinna. In each of the regions transepidermal water loss (TEWL), skin hydration and skin pH were measured. For transepidermal water loss, the lowest values were observed in the pinna (10.54 g/hm²), while the highest values were observed in the lip region (30.98 g/hm²). In the case of skin hydration the lowest values were observed for the thorax region (1.96 CU), and the highest for the lip region (48.28 CU). For skin pH, the lowest results were obtained in the pinna (7.03), and the highest in the lumbar region (8.05).
Źródło:
Polish Journal of Veterinary Sciences; 2013, 16, 4
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of non-specific anti-pruritus treatment with cyclosporine A on transepidermal water loss (TEWL) in natural atopic dermatitis in dogs
Autorzy:
Zajac, M.
Szczepanik, M.
Wilkolek, P.
Adamek, L.
Pomorski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/30117.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Opis:
Atopic dermatitis is a common allergic skin disease in dogs. Monitoring the progress of treatment and the assessment of the severity of disease symptoms are crucial elements of the treatment procedure. One of the common means of assessing the severity of the clinical signs of the disease is the CADESI 03. Research studies have pointed to a possibility of assessing the severity of skin lesions by means of measuring biophysical skin parameters such as TEWL, skin hydration and erythema intensity. The aim of the study was the assessment of changes in TEWL and CADESI values measured in ten different body regions during non-specific anti-pruritus treatment. The examination was performed on ten dogs with atopic dermatitis (age from 2.5 years to 7 years, mean age 3.8 years). The measurements were performed in the following body regions: the lumbar region, the right axillary fossa, the right inguinal region, the ventral abdominal region, the right lateral thorax region, the internal surface of the auricle, interdigital region of the right forelimb, cheek, bridge of nose and the lateral site of antebrachum. A statistically significant decrease in CADESI values was reported starting from the second week of treatment. In the case of the mean TEWL values, a fall was observed after one week of treatment in the ventral abdominal region and the interdigital region, after two weeks of treatment in the axillary fossa and the inguinal region, and after three weeks in the cheek and the lateral thorax region. There was no statistically significant decrease in TEWL values in the course of treatment in four other regions.
Źródło:
Polish Journal of Veterinary Sciences; 2015, 18, 2
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis and Modelling on Radiated Noise of a Typical Fishing Boat Measured in Shallow Water Inspired by AQUO Project’s Model
Autorzy:
Peng, Z.
Fan, J.
Wang, B.
Powiązania:
https://bibliotekanauki.pl/articles/177092.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
radiated noise
South China Sea
predicted model
shallow water
transmission loss
Opis:
The shipping noise near channels and ports is an important contribution to the ambient noise level, and the depth of these sites is often less than 100 m. However less attention has been paid to the measurement in shallow water environments (Brooker, Humphrey, 2016). This paper presents extensive measurements made on the URN (underwater radiated noise) of a small fishing boat in the South China Sea with 87 m depth. The URN data showed that the noise below 30 Hz was dominated by the background noise. The transmission loss (TL) was modelled with FEM (finite element method) and ray tracing according to the realistic environmental parameters in situ. The discrepancy between the modelled results and the results using simple law demonstrates both sea surface and bottom have significant effect on TL for the shallow water, especially at low frequencies. Inspired by the modelling methodology in AQUO (Achieve QUieter Oceans) project (Audoly et al., 2015), a predicted model applied to a typical fishing boat was built, which showed that the URN at frequencies below and above 100 Hz was dominated by non-cavitation propeller noise and mechanical noise, respectively. The agreement between predicted results and measured results also demonstrates that this modelling methodology is effective to some extent.
Źródło:
Archives of Acoustics; 2018, 43, 2; 263-273
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pochłanianie mikrofal przez nieutwardzone masy formierskie ze szkłem wodnym
Microwave Absorption by Unhardened Molding Sands with Water-Glass
Autorzy:
Stachowicz, M.
Granat, K.
Powiązania:
https://bibliotekanauki.pl/articles/379879.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
odlewnictwo
mikrofale
szkło wodne
pomiar stratności
masa sypka
masa samoutwardzalna
founding
microwaves
water glass
loss factor measurement
self hardening moulding sand
Opis:
W pracy przedstawiono wyniki badań wstępnych pochłaniania fal elektromagnetycznych o częstotliwości 2,45 GHz przez masy formierskie sporządzone z różnymi gatunkami szkła wodnego sodowego. Zakres badań obejmował określenie wartości strat energii mikrofal, na podstawie pomiarów tłumienności wykonanych w trakcie ich propagacji przez wypełniony masą falowód. Pomiary strat mocy sygnału mikrofalowego prowadzono z zastosowaniem unikatowego stanowiska mikrofalowej linii szczelinowej. Na podstawie uzyskanych wyników badań stwierdzono, że stanowisko to wspomaga, na podstawie zmierzonych wartości strat sygnału mikrofalowego, ocenę skuteczności pochłaniania mikrofal przez kwarcowe masy formierskie zawierające różną ilość wybranych gatunków spoiw stosowanych w masach SMS. Przeprowadzone badania wykazały, że straty sygnału mikrofalowego związane są z: modułem i ilością wprowadzonego do masy szkła wodnego.
In the paper are presented results of the preliminary research of absorption of electromagnetic waves with a frequency of 2.45 GHz by molding sands prepared with different kinds of sodium water-glass binders. The scope of the research included assessment of the losses of microwave energy, which were based on the loss measurements during their propagation through the waveguide filled with the molding sand. Measurements of the losses of microwave signal power was carried out using the unique test stand, which was the microwave slot line. On the basis of the preliminary research it was found, that this test stand helps to evaluate the effectiveness of microwave absorption by quartz molding sands containing different number of selected kinds of binders used in SMS sandmixes, by the usage of measured values of the microwave signal losses. Research have shown, that the loss of the microwave signal are associated with: the module and the amount of water-glass binder added to the molding sand.
Źródło:
Archives of Foundry Engineering; 2013, 13, 1 spec.; 169-174
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies