Tytuł:
Fire resistance assessment of the long-span steel truss girder
Ocena odporności ogniowej stalowej kratownicy o dużej rozpiętości
Autorzy:
Woźniczka, P.
Powiązania:
https://bibliotekanauki.pl/articles/231439.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
odporność ogniowa
hala wielkokubaturowa
rozpiętość duża
pożar
analiza właściwości
fire resistance
large-space hall
long-span
fire
performance analysis
Opis:
The performance-based analysis of the large-space steel sports hall is presented. Load-bearing structure of the hall consists of spatial long-span truss girders that are made of modern square hollow sections. Both fire development analysis and mechanical response analysis are discussed in detail. Fire Dynamics Simulator and Safir programs are used. Main focus is put on the factors that could affect the final fire resistance of the structure. Uniform and non-uniform heating, different boundary conditions and local imperfections are taken into account. Structures with and without fireproof insulation are considered. Values of the critical temperature, failure modes and fire resistance estimated for various cases are presented. Computer simulations were carried out both for fire growth and decay phase. As a result it is clearly shown that some reductions of the required fireproof insulation are possible. Moreover, the structure without complete traditional fireproof insulation is able to survive not only the direct fire exposure but also the cooling phase.
Aktualne normy europejskie EN 1991-1-2 i EN 1993-1-2 dopuszczają do stosowania różnorodne metody oceny odporności ogniowej, które mogą być wykorzystane zarówno w odniesieniu do pojedynczych elementów jak i całych ustrojów nośnych. Podejście obliczeniowe bazujące na właściwościach danej strefy pożarowej (tzw. performance-based approach) powinno uwzględniać zarówno analizę rozwoju pożaru jak i odpowiedzi mechanicznej konstrukcji. Wykorzystanie tego typu metody może być szczególnie istotne w przypadku obiektów o stosunkowo dużych kubaturach stref pożarowych, takich jak na przykład wielkogabarytowe hale o konstrukcji stalowej. Możliwy jest wówczas nie tylko lepszy wgląd w zachowanie się konstrukcji w warunkach pożaru ale istnieje także możliwość dostosowania izolacji ogniochronnej do rzeczywistego zapotrzebowania. Jednocześnie przeprowadzenie kompletnych symulacji typu "performance-based" jest niezwykle czasochłonne oraz wymaga połączenia wiedzy z zakresu inżynierii pożarowej oraz inżynierii lądowej. Dodatkowo wpływ niektórych czynników (takich jak przykładowo lokalne imperfekcje łukowe) na prognozowaną odporność ogniową nie został do tej pory w pełni rozpoznany. W tej sytuacji w artykule przedstawiono opartą na charakterystyce danej strefy pożarowej analizę odporności ogniowej wielkogabarytowej hali sportowej o konstrukcji stalowej. Rozpatrywana hala charakteryzuje się zarówno znacznymi wymiarami w rzucie (70m x 60m) jak i stosunkowo dużą wysokością (16.5m). Główny ustrój nośny składa się z trójpasowych dźwigarów kratowych o rozpiętości 60m, rozmieszczonych w rozstawie co 6m. Obliczenia rozwoju pożaru wykonano za pomocą programu Fire Dynamics Simulator. Do opracowania analizy odpowiedzi mechanicznej konstrukcji wykorzystano program Safir.
Źródło:
Archives of Civil Engineering; 2020, 66, 2; 63-75
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Full-scale fire resistance testing of concrete beams reinforced with various FRP reinforcement
Ognioodporność pełnowymiarowych belek betonowych zbrojonych prętami FRP o zróżnicowanym składzie
Autorzy:
Protchenko, K.
Urbański, M.
Powiązania:
https://bibliotekanauki.pl/articles/1849735.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
polimer zbrojony włóknami
FRP
pręt FRP
zbrojenie hybrydowe
belka betonowa
odporność ogniowa
fibre reinforced polymer
FRP bar
hybrid reinforcement
concrete beam
fire resistance
Opis:
The widespread use of Fibre-Reinforced Polymers (FRP) reinforced concrete (RC) structural members is hindered by their low fire resistant characteristics, limiting their use to cases, where fire resistance is not a priority. Presented and discussed are experimental results pertaining to the flexural members subjected to heating and simultaneous loading. Solely non-metallic FRP bars: (i) Basalt FRP (BFRP), (ii) Hybrid FRP (HFRP) with carbon and basalt fibres and (ii) nano-Hybrid FRP (nHFRP) with modified epoxy resin, were used as internal reinforcement for beams. The destruction of the beams was caused in different ways, beams reinforced with BFRP bars were destroyed by reinforcement failure while those reinforced with hybrid FRP bars were destroyed by concrete crushing. The BFRP reinforced beams obtained a maximum temperature, measured directly on the bars, of 917°C, compared to beams reinforced with hybrid FRP bars, where the temperature on the bars reached 400-550°C at failure. Moreover, the highest registered ductility was obtained for BFRP reinforced beams as well, where the maximum deflections reached approximately 16 cm.
Degradacja nośności zbrojenia konstrukcji w postaci prętów FRP (ang. Fibre-Reinforced Polymers) może być spowodowane kilkoma czynnikami, do których należą: rodzaje włókien, osnowy (matrycy), ich objętościowy udział, sposób wytwarzania, jakość składników prętów. Jednakże głównym czynnikiem jest przede wszystkim wpływ temperatury w zbrojeniu FRP, występujący w trakcie oddziaływania warunków pożarowych. Zjawisko redukcji nośności konstrukcji i przyczepności zbrojenia do betonu pojawia się, gdy temperatura prętów FRP zbliża się do temperatury zeszklenia Tg osnowy (matrycy), której wartość zależy od rodzaju żywicy. Jednym z rozwiązań w tym zakresie jest zastosowanie większej otuliny lub zastosowanie dodatkowego systemu ochrony przeciwpożarowej. Jednak obecnie dostępne dane na temat zachowania elementów betonowych zbrojonych FRP w warunkach pożarowych, są ograniczone, szczególnie w odniesieniu do nośności belek po poddaniu ich oddziaływaniu wysokich temperatur. Dlatego odporność ogniowa elementów betonowych zbrojonych FRP jest jednym z podstawowych czynników, które utrudniają powszechne stosowanie tych materiałów jako alternatywy dla zbrojenia stalowego. W artykule opisano zachowanie się belek betonowych, zbrojonych prętami FRP wyprodukowanych na bazie włókien bazaltowych i węglowych, poddawanych testom odporności ogniowej. Badania belek narażonych na wysokie temperatury, przeprowadzono według scenariusz pożaru umownego zgodnie z krzywą standardową ISO-834 [13], [29]. Ponieważ głównym celem było zbadanie wpływu rodzaju zbrojenia FRP na odporność ogniową belek, zastosowano różne rodzaje prętów w strefie rozciągania (dolna część belek): (i) zbrojenie na bazie włókien bazaltowych BFRP (ang. Basalt FRP), (ii) hybrydowe zbrojenie HFRP (ang. Hybrid FRP) z włóknami węglowymi i bazaltowymi oraz (ii) nanohybrydowymi prętami nHFRP (ang. nano-Hybrid FRP) ze zmodyfikowaną żywicą epoksydową. Ponadto, badane elementy charakteryzowały się zmiennym stopniem zbrojenia, w celu określenia wpływu średnicy i liczby prętów na nośność belek podczas i po oddziaływaniu wysokich temperatur.
Źródło:
Archives of Civil Engineering; 2020, 66, 4; 119-136
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fire resistance evaluation for a steel hall transverse frame depending on the simplification degree of the computational model applied
Ocena odporności ogniowej ramy poprzecznej hali stalowej w zależności od stopnia uproszczenia zastosowanego modelu obliczeniowego
Autorzy:
Maślak, Mariusz
Pazdanowski, Michał
Suchodoła, Maciej
Woźniczka, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2174094.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Opis:
It is presented in detail how the selection of a structural model describing the behaviour of a steel hall transverse frame when subject to fire exposure in a more or less complex way may affect the fire resistance evaluation for such a frame. In the examples compiled in this paper the same typical one-aisle and single-story steel hall is subjected to simulated fire action, each time following the same fire development scenario. A resultant fire resistance is identified individually in each case, using various computational models, on an appropriate static equilibrium path obtained numerically. The resulting estimates vary, not only in the quantitative sense, but also in terms of their qualitative interpretation. It is shown that the greater the simplification of the model used, the more overstated the estimated fire resistance is in relation to its real value. Such an overestimation seems to be dangerous to the user, as it gives him an illusory but formally unjustified sense of the guaranteed safety level.
Pokazano jak dobór schematu statycznego pojedynczej ramy poprzecznej typowego ustroju nośnego hali stalowej determinuje uzyskaną z obliczeń dla tej ramy wartość poszukiwanej odporności ogniowej. Odporność tę interpretuje się z reguły jako czas przez który badana rama w warunkach ekspozycji pożarowej zachowuje zdolność do bezpiecznego przenoszenia przyłożonych do niej obciążeń. W celach porównawczych, dla tego samego scenariusza rozwoju pożaru, odpowiadającego standardowym warunkom nagrzewania, i dla tej samej ramy, rozpatrzono odpowiadające sobie rozmaite modele obliczeniowe o różnym stopniu złożoności. Reprezentatywną miarą odporności na oddziaływanie monotonicznie narastającej w czasie pożaru temperatury elementów stalowych było w każdym z rozpatrywanych przypadków wyczerpanie możliwości efektywnego przenoszenia obciążeń, identyfikowane na ścieżce równowagi statycznej. Zestawienie i porównanie uzyskanych wyników doprowadziło do konstatacji, że im większy stopień uproszczenia zastosowanego modelu obliczeniowego tym bardziej zawyżone otrzymane na jego podstawie oszacowanie poszukiwanej odporności, przeszacowujące realnie gwarantowany użytkownikowi poziom bezpieczeństwa. Wykazano, że znaczący wpływ na finalny wynik analizy może mieć formalne uwzględnienie w zastosowanym modelu obliczeniowym mimośrodów wynikających ze sposobu oparcia płatwi na ryglu, co na ogół nie jest dostrzegane. Generują one bowiem dodatkowy moment skręcający, który w sytuacji zmniejszonej wskutek oddziaływania temperatury pożarowej sztywności rygla może przyspieszać jego utratę stateczności. Szczególne znaczenie dla wynikowej odporności ogniowej analizowanej ramy ma również zachowanie się w pożarze płatwi dachowych usztywniających rygiel. Płatwie te, z uwagi na mniejszy przekrój, nagrzewają się bowiem znacznie szybciej niż rygiel i słupy ramy poprzecznej. Stosunkowo wcześnie zatem, przy monotonicznym wzroście temperatury, przestają efektywnie podtrzymywać ten rygiel, w efekcie czego narastanie jego ugięcia, często decydujące o nośności ramy, nie jest już w żaden sposób hamowane. W rozważanych modelach formalnych pominięto wpływ potencjalnie możliwych imperfekcji geometrycznych, zarówno tych o charakterze globalnym jak i tych lokalnych. W prowadzonej przez autorów analizie nie wydaje się on bowiem mieć istotnego znaczenia. Nie uwzględniono również faktu narastania wraz z rozwojem pożaru podatności węzłów.
Źródło:
Archives of Civil Engineering; 2022, 68, 4; 219--235
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ambiguity in determining the critical temperature of a steel sway frame with semi-rigid joints
Niejednoznaczność w wyznaczaniu temperatury krytycznej stalowej ramy przechyłowej z podatnymi węzłami
Autorzy:
Maslak, M.
Pazdanowski, M.
Snela, M.
Powiązania:
https://bibliotekanauki.pl/articles/1849756.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
odporność ogniowa
rama stalowa
temperatura krytyczna
węzeł sztywny
węzeł półsztywny
węzeł doczołowy
węzeł belka-słup
fire resistance
steel frame
critical temperature
fully rigid joint
semi rigid joint
end plate joint
beam to column joint
Opis:
The problem of uniqueness and representativeness of steel frame fire resistance assessment is considered in this paper. The thesis, that the selection of analysis method determines the result in both qualitative and quantitative terms is given scrutiny. It is also shown, that the differences between computed values may be significant. The selection of an appropriate computational model for an analysis of this type seems to be especially important, as the possible overestimation of the fire resistance determined during computation is equivalent to an unjustified optimism of the user with respect to the safety level warranted. In the considerations presented here the critical temperature determined for the whole bearing structure is considered as the measure of sought resistance. The determined temperature is associated with the bearing structure reaching the bearing capacity limit state subject to fire conditions, treated as accidental design situation. Two alternative computational methods have been applied during calculations: the first one - classical, based on 1st order statics and using the buckling length concept for members of the considered frame, and the second one - taking account of 2nd order phenomena via simple amplification of the horizontal loads applied to the frame. Special attention has been paid to the influence exerted on the final fire resistance of the considered structure by the real joint rigidity, decreasing with increasing temperature of the structural members. The obtained results differ not only in the value of determined temperature but also in the indicated location of the weakest frame component, determining its safety.
W pracy rozważa się problem jednoznaczności i reprezentatywności oszacowania odporności ogniowej ramy stalowej. Weryfikacji poddano tezę, że wybór metody analizy determinuje uzyskany wynik zarówno pod względem ilościowym jak i jakościowym, a różnice pomiędzy wyliczonymi wartościami mogą okazać się znaczące. Dobór miarodajnego modelu obliczeniowego w tego typu analizie wydaje się być szczególnie ważny, bowiem ewentualne przeszacowanie wyznaczonej z obliczeń odporności jest równoznaczne z nieuzasadnionym optymizmem użytkownika budynku co do gwarantowanego mu poziomu bezpieczeństwa. W prezentowanych rozważaniach miarą poszukiwanej odporności jest temperatura krytyczna specyfikowana dla całego ustroju nośnego. Nie zależy ona od prognozowanego scenariusza rozwoju pożaru i z tego względu może zostać uznana za pewnego rodzaju charakterystykę samej konstrukcji. Wyznaczana temperatura kojarzona jest z osiągnięciem przez ustrój nośny stanu granicznego nośności w warunkach pożaru traktowanego jako wyjątkowa sytuacja projektowa. Nie oznacza to jednak natychmiastowej katastrofy badanej konstrukcji ale jedynie sytuację, gdy prawdopodobieństwo tego rodzaju zdarzenia staje się już na tyle duże że nie może być dalej akceptowane. Do szczegółowej analizy wykorzystano dwie alternatywne procedury obliczeń: pierwszą - opartą o klasyczną statykę pierwszego rzędu, z wykorzystaniem koncepcji długości wyboczeniowej elementów badanej ramy, i drugą - uwzględniającą efekty drugiego rzędu przez prostą amplifikację przyłożonego do tej ramy obciążenia poziomego.
Źródło:
Archives of Civil Engineering; 2020, 66, 4; 611-632
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies