Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "biomedical imaging" wg kryterium: Wszystkie pola


Wyświetlanie 1-2 z 2
Tytuł:
A 3D directive microwave antenna for biomedical imaging application
Autorzy:
Ullah, M. A.
Alam, T.
Islam, M. T.
Powiązania:
https://bibliotekanauki.pl/articles/200173.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
antenna
3D antenna
microwave sensor
microwave imaging
unidirectional
antena
antena 3D
czujnik mikrofalowy
obrazowanie mikrofalowe
Opis:
A directive three dimensional antenna, using folded radiating structure has been presented for the application of microwave imaging in clinical diagnosis. Two reflector walls have been introduced to achieve higher gain and directive radiation pattern along with the folding technique. The shorting wall technique is utilized to reduce the overall antenna size and to get resonance at a lower frequency. The proposed antenna obtained operating band at 1.67 GHz to 1.74 GHz. The dimension of the 3D radiating structure is 40£25£10.5 mm3. The antenna has an average realized gain of 5.2 dBi. Owing to the unidirectional radiation pattern, high gain and operating bandwidth within lower microwave frequency, the proposed antenna has potential to be used in microwave imaging for biomedical diagnosis. Also, the antenna has been utilized to compute an imaging phenomenon to detect abnormality in human head and result is presented. The design and simulation process are performed in the CST Microwave Studio software. The antenna is fabricated from 0.2 mm thick copper sheets. The results of the fabricated antenna are measured using PNA Network Analyzer (N5227A) and Satimo Star Lab.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2018, 66, 3; 355-360
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Medical image measurement and characterization: extracting mechanical and thermal stresses for surgery
Autorzy:
Lay-Ekuakille, Aimé
Ugwiri, Moise Avoci
Liguori, Consolatina
Singh, Satya P.
Rahman, Md Zia Uhr
Veneziano, Domenico
Powiązania:
https://bibliotekanauki.pl/articles/1848960.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
infrared imaging
robotic surgery
imaging for cancer detection
bioinstrumentation
laparoscopy
biomedical measurements
biomechanical and stress
Opis:
Whatever the type of surgery related to inner organs, traditional or robotic, the contact with them during surgery is a key moment for pursuing the intervention. Contacts by means of surgery instruments namely scalpels, staples, clamps, graspers, etc. are decisive moments. False, and erroneous touching and manoeuvring of organs operated on can cause irreversible damage as regard morphological aspects (outer impact) and physiological aspects (inner impact). The topic is a great challenge in the effort to measure and characterize damages. In general, electrical instruments for surgery employ the following technologies: ultrasound, radiofrequency (monopolar, and bipolar), and laser. They all result in thermal damages difficult to evaluate. The article proposes a method for a pre-screening of organ features during robotic surgery sessions by pointing out mechanical and thermal stresses. A dedicated modelling has been developed based on experimental activities during surgery session. The idea is to model tissue behaviour from real images to help surgeons to be aware of handling during surgery. This is the first step for generalization by considering the type of organ. The measurement acquisitions have been performed by means of an advanced external camera located over the surgery quadrant. The modelling and testing have been carried out on kidneys. The modelling, carried out through Comsol Multiphysics, is based on the bioheat approach. A further comparative technique has been implemented. It is based on computer vision for robotics. The findings of human tissue behavior exhibit reliable results.
Źródło:
Metrology and Measurement Systems; 2021, 28, 1; 3-21
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies