Tytuł:
Research on torque ripple suppression of brushless DC motor based on PWM modulation
Autorzy:
Daode, Zhang
Wei, Lingkang
Hu, Xinyu
Zhang, Chupeng
Li, Xuesheng
Powiązania:
https://bibliotekanauki.pl/articles/141390.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
DC brushless motor
electric propulsion
fuzzy PID control
torque ripple
PWM_ON_PWM modulation
Opis:
Brushless DC motors are often used as the power sources for modern ship electric propulsion systems. Due to the electromagnetic torque ripple of the motor, the traditional control method reduces the drive performance of the motor under load changes. Aiming at the problem of the torque ripple of the DC brushless motor during a noncommutation period, this paper analysis the reasons for the torque ripple caused by pulsewidth modulation (PWM), and proposes a PWM_ON_PWM method to suppress the torque ripple of the DC brushless motor. Based on the mathematical model of a DC brushless motor, this method adopts a double closed-loop control method based on fuzzy control to suppress the torque ripple of the DC brushless motor. The fuzzy control technology is integrated into the parameter tuning process of the proportional–integral–derivative (PID) controller to effectively improve the stability of the motor control system. Under the Matlab/Simulink platform, the response performance of different PID control methods and the torque characteristics of different PWM modulation methods are simulated and compared. The results show that the fuzzy adaptive PID control method has good dynamic response performance. It is verified that the PWM_ON_PWM modulation method can effectively suppress the torque ripple of the motor during non-commutation period, improve the stability of the double closed-loop control system and meet the driving performance of the motor under different load conditions.
Źródło:
Archives of Electrical Engineering; 2019, 68, 4; 843-858
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Averaged models of pulse-modulated DC-DC power converters. Part II. Models based on the separation of variables
Autorzy:
Janke, W.
Powiązania:
https://bibliotekanauki.pl/articles/140855.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power converters
pulse width modulation (PWM)
BUCK
buck-boost
BOOST
averaged models
Opis:
The separation of variables approach to formulate the averaged models of DC-DC switch-mode power converters is presented in the paper. The proposed method is applied to basic converters such as BUCK, BOOST and BUCK-BOOST. The ideal converters or converters with parasitic resistances, working in CCM and in DCM mode are considered. The models are presented in the form of equation systems for large signal, steady-state and small-signal case. It is shown, that the models obtained by separation of variables approach differ in some situations from standard models based on switch averaging method.
Źródło:
Archives of Electrical Engineering; 2012, 61, 4; 633-654
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An active power filter based on a hybrid converter topology – Part 1
Autorzy:
Gwóźdź, Michał
Ciepliński, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/2173586.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
shunt active power filter
pulse width modulation
PWM
sigma-delta modulator
silicon carbide
bocznikowy filtr mocy czynnej
modulacja szerokości impulsu
modulator sigma-delta
węglik krzemu
Opis:
This paper presents a concept of a shunt active power filter, which is able to provide more precise mapping of its input current drawn from a power line in a reference signal, as compared to a typical filter solution. It can be achieved by means of an interconnection of two separate power electronics converters making, as a whole, a controlled current source, which mainly determines the quality of the shunt active filter operation. One of these power devices, the “auxiliary converter”, corrects the total output current, being a sum of output currents of both converters, toward the reference signal. The rated output power of the auxiliary converter is much lower than the output power of the main one, while its frequency response is extended. Thanks to both these properties and the operation of the auxiliary converter in a continuous mode, pulse modulation components in the filter input current are minimized. Benefits of the filter are paid for by a relatively small increase in the complexity and cost of the system. The proposed solution can be especially attractive for devices with higher output power, where, due to dynamic power loss in power switches, a pulse modulation carrier frequency must be lowered, leading to the limitation of the “frequency response” of the converter. The concept of such a system was called the “hybrid converter topology”. In the first part of the paper, the rules of operation of the active filter based on this topology are presented. Also, the results of comparative studies of filter simulation models based on both typical, i.e. single converter, and hybrid converter topologies, are discussed.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 1; art. no. e136218
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An active power filter based on a hybrid converter topology – Part 1
Autorzy:
Gwóźdź, Michał
Ciepliński, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/2090725.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
shunt active power filter
pulse width modulation
PWM
sigma-delta modulator
silicon carbide
bocznikowy filtr mocy czynnej
modulacja szerokości impulsu
modulator sigma-delta
węglik krzemu
Opis:
This paper presents a concept of a shunt active power filter, which is able to provide more precise mapping of its input current drawn from a power line in a reference signal, as compared to a typical filter solution. It can be achieved by means of an interconnection of two separate power electronics converters making, as a whole, a controlled current source, which mainly determines the quality of the shunt active filter operation. One of these power devices, the “auxiliary converter”, corrects the total output current, being a sum of output currents of both converters, toward the reference signal. The rated output power of the auxiliary converter is much lower than the output power of the main one, while its frequency response is extended. Thanks to both these properties and the operation of the auxiliary converter in a continuous mode, pulse modulation components in the filter input current are minimized. Benefits of the filter are paid for by a relatively small increase in the complexity and cost of the system. The proposed solution can be especially attractive for devices with higher output power, where, due to dynamic power loss in power switches, a pulse modulation carrier frequency must be lowered, leading to the limitation of the “frequency response” of the converter. The concept of such a system was called the “hybrid converter topology”. In the first part of the paper, the rules of operation of the active filter based on this topology are presented. Also, the results of comparative studies of filter simulation models based on both typical, i.e. single converter, and hybrid converter topologies, are discussed.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 1; e136218, 1--10
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies