Tytuł:
Modelling and predicting sound level around selected sections of motorway A2
Modelowanie i prognozowanie poziomu dźwięku w otoczeniu wybranego odcinka autostrady A2
Autorzy:
Orczyk, M.
Tomaszewski, F.
Powiązania:
https://bibliotekanauki.pl/articles/224353.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
hałas drogowy
hałas na autostradzie
pomiar hałasu
modelowanie hałasu
traffic noise
motorway
noise modelling
diffraction
Opis:
This article presents potential of modelling and predicting noise level around the section of motorway A2 Komorniki – Krzesiny. The models were worked out on the basis of sound levels registered in three stages of research connected with phases of utilization of this motorway (measurement of acoustic background without traffic, measurements after opening section Komorniki – Krzesiny and noise measurement after opening section Nowy Tomysl – Konin). The models were verified on the basis of actual number of vehicles which passed by section Komorniki – Krzesiny on random day and at random hour.
W artykule przedstawiono możliwości modelowania i prognozowania hałasu w otoczeniu fragmentu autostrady A2 Komorniki - Krzesiny. Modele opracowano na podstawie rejestracji poziomów dźwięku w trzech etapach badań związanych z fazami eksploatacji autostrady (pomiar tła akustycznego - bez ruchu pojazdów, pomiary po oddaniu odcinka Komorniki - Krzesiny do eksploatacji oraz pomiary hałasu po uruchomieniu nowego odcinka autostrady Nowy Tomyśl - Konin). Opracowane modele zweryfikowano w oparciu o rzeczywistą liczbę pojazdów, które przejechały przez odcinek Komorniki - Krzesiny w losowo wybranym dniu i godzinie.
Źródło:
Archives of Transport; 2011, 23, 2; 173-190
0866-9546
2300-8830
Pojawia się w:
Archives of Transport
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Treatment of wastewater from service areas at motorways
Oczyszczanie ścieków z miejsc obsługi podróżnych przy autostradzie
Autorzy:
Makowska, M.
Mazurkiewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/205279.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
motorway service areas
local treatment plants
biofilters
wastewater treatment
facilities at transport routes
miejsca obsługi podróżnych
MOP
natężenie ruchu
autostrada A2
oczyszczalnie lokalne
biofiltr
jakość ścieków
Opis:
This paper deals with wastewater treatment systems placed in motorway service areas (MSAs). In the years 2008-2009 eight of such facilities installed on the stretch of the A2 motorway between Poznań and Nowy Tomyśl were examined and analyzed. The system consists of a septic tank, a submerged aerated biofilter and an outflow filter. The volume of traffic on the highway was analyzed, the amount of water use was measured and peak factors were calculated. On this basis it was concluded that the inflows to the wastewater treatment systems in many cases exceeded the nominal design values. Based on the analysis of effluent quality it was found that the effects of plant operation in large part did not meet the requirements. It was found that the bioreactor aeration system and the design of the suspension separator (outflow filter) should be modified. One of the solutions was to use the soil-reed bed for wastewater treatment. The treatment of wastewater from the MSAs is a task that must take into account the unusual character of these facilities and the atypical quality of the effluent.
Praca dotyczy systemów oczyszczania ścieków w Miejscach Obsługi Podróżnych (MOP) przy autostradach. Badano i analizowano 8 instalacji zamontowanych w MOP-ach przy autostradzie A2 między Poznaniem a Nowym Tomyślem. Systemy składają się z osadnika gnilnego, zanurzonego, napowietrzanego złoża biologicznego i filtra odpływowego. Analizowano natężenie ruchu na autostradzie, ilość zużywanej wody oraz jakość ścieków na wlocie i wylocie z bioreaktora. Na tej podstawie stwierdzono, że wielkość oczyszczalnie nie jest adekwatna do ilości i jakości dopływających ścieków. Stwierdzono, że jakość odpływu jest niezadowalająca oraz zaproponowano zmiany konstrukcyjne i technologiczne.
Źródło:
Archives of Environmental Protection; 2016, 42, 4; 80-89
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies