Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę ""Laskowski"" wg kryterium: Wszystkie pola


Tytuł:
Entropy generation in a condenser and related correlations
Autorzy:
Laskowski, R.
Jaworski, M.
Smyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/240683.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
steam condenser
entropy generation
kondensator pary
generowanie entropii
Opis:
The paper presents an analysis of relations describing entropy generation in a condenser of a steam unit. Connections between entropy generation, condenser ratio, and heat exchanger effectiveness, as well as relations implied by them are shown. Theoretical considerations allowed to determine limits of individual parameters which describe the condenser operation. Various relations for average temperature of the cold fluid were compared. All the proposed relations were verified against data obtained using a simulator and actual measurement data from a 200 MW unit condenser. Based on data from a simulator it was examined how the sum of entropy rates, steam condenser effectiveness, terminal temperature difference and condenser ratio vary with the change in the inlet cooling water temperature, mass flow rate of steam and the cooling water mass flow rate.
Źródło:
Archives of Thermodynamics; 2015, 36, 2; 27-48
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Occurrence of acanthocephalans in notothenioid fishes in the Beagle Channel (Magellanic sub-region, sub-Antarctic)
Autorzy:
Laskowski, Zdzisław
Zdzitowiecki, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/2051657.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Sub-Antarctic
Beagle Channel
Acanthocephala
notothenioid fishes
Źródło:
Polish Polar Research; 2009, 30, 2; 179-186
0138-0338
2081-8262
Pojawia się w:
Polish Polar Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental investigation of single-phase microjet cooling of microelectronics
Autorzy:
Rusowicz, A.
Leszczyński, M.
Grzebielec, A.
Laskowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/240614.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cooling
heat transfer
microjets
microprocessor
chłodzenie
wymiana ciepła
mikrojety
mikroprocesor
Opis:
Development of electronics, which aims to improve the functionality of electronic devices, aims at increasing the packing of transistors in a chip and boosting clock speed (the number of elementary operations per second). While pursuing this objective, one encounters the growing problem of thermal nature. Each switching of the logic state at the elementary level of an integrated circuit is associated with the generation of heat. Due to a large number of transistors and high clock speeds, higher heat flux is emitted by the microprocessor to a level where the component needs to be intensively cooled, or otherwise it will become overheated. This paper presents the cooling of microelectronic components using microjets.
Źródło:
Archives of Thermodynamics; 2015, 36, 3; 139-147
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Larval ascaridoid nematodes (Anisakidae) in fish from the South Shetland Islands (Southern Ocean)
Autorzy:
Rokicki, Jerzy
Rodjuk, Galina
Zdzitowiecki, Krzysztof
Laskowski, Zdzisław
Powiązania:
https://bibliotekanauki.pl/articles/2051668.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Antarctica
ascaridoid nematodes
fish
long-term change
Źródło:
Polish Polar Research; 2009, 30, 1; 49-58
0138-0338
2081-8262
Pojawia się w:
Polish Polar Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The affective tone of narration and posttraumatic growth in organ transplant recipients
Autorzy:
Zięba, Mariusz
Zatorski, Mateusz
Boczkowska, Marta
Gozdowska, Jolanta
Kieszek, Rafał
Laskowski, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/430494.pdf
Data publikacji:
2015-09-01
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
narratives
affective tone
posttraumatic growth
Opis:
The aim of the study was to verify the hypothesis that positive affective tone of narratives is connected to the experience of posttraumatic growth among transplant patients. Kidney transplant patients (N = 51) and liver transplant patients (N = 48) participated in the study. In the first stage, about 10 weeks after transplant, the participants told two stories about important, freely chosen events from their lives. During the second meeting 10-12 months later we measured posttraumatic growth. Results indicated that the affective tone of narratives about past events was associated with the level of post-traumatic growth measured 10-12 months later. This proves that the affective tone of narratives about life, understood as a relatively constant individual characteristic, promote posttraumatic growth.
Źródło:
Polish Psychological Bulletin; 2015, 46, 3; 376-383
0079-2993
Pojawia się w:
Polish Psychological Bulletin
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Contribution to the knowledge of the infection with Acanthocephala of a predatory Antarctic ice−fish Chaenocephalus aceratus
Autorzy:
Laskowski, Zdzisław
Zdzitowiecki, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/2051582.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
West Antarctic
Acanthocephala
Chaenocephalus aceratus
infection
host sex
Źródło:
Polish Polar Research; 2010, 4; 303-308
0138-0338
2081-8262
Pojawia się w:
Polish Polar Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The helminth fauna of some notothenioid fishes collected from the shelf of Argentine Islands, West Antarctica
Autorzy:
Laskowski, Zdzisław
Zdzitowiecki, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/2051933.pdf
Data publikacji:
2005
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Antarctica
Argentine Islands
Vernadsky Station
parasitic worms
fishes
infection
Źródło:
Polish Polar Research; 2005, 26, 4; 315-324
0138-0338
2081-8262
Pojawia się w:
Polish Polar Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Possibility of using adsorption refrigeration unit in district heating network
Autorzy:
Grzebielec, A.
Rusowicz, A.
Jaworski, M.
Laskowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/240811.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
refrigeration
adsorption refrigeration
air conditioning
district heating network
chłodzenie
absorpcja
klimatyzacja
sieć ciepłownicza
Opis:
Adsorption refrigeration systems are able to work with heat sources of temperature starting with 50°C. The aim of the article is to determine whether in terms of technical and economic issues adsorption refrigeration equipment can work as elements that produce cold using hot water from the district heating network. For this purpose, examined was the work of the adsorption air conditioning equipment cooperating with drycooler, and the opportunities offered by the district heating network in Warsaw during the summer. It turns out that the efficiency of the adsorption device from the economic perspective is not sufficient for production of cold even during the transitional period. The main problem is not the low temperature of the water supply, but the large difference between the coefficients of performance, COPs, of adsorption device and a traditional compressor air conditioning unit. When outside air temperature is 25°C, the COP of the compressor type reaches a value of 4.49, whereas that of the adsorption device in the same conditions is 0.14. The ratio of the COPs is 32. At the same time ratio between the price of 1 kWh of electric power and 1 kWh of heat is only 2.85. Adsorption refrigeration equipment to be able to compete with compressor devices, should feature COPads efficiency to be greater than 1.52. At such a low driving temperature and even changing the drycooler into the evaporative cooler it is not currently possible to achieve.
Źródło:
Archives of Thermodynamics; 2015, 36, 3; 15-24
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling and Designing Acoustical Conditions of the Interior – Case Study
Autorzy:
Kostek, B.
Laskowski, S.
Mizgier, K.
Powiązania:
https://bibliotekanauki.pl/articles/176652.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic field analysis
acoustic field modeling
acoustic conditions measurements
acoustic conditions analysis
sound reinforcement system design
Opis:
The primary aim of this research study was to model acoustic conditions of the Courtyard of the Gdańsk University of Technology Main Building, and then to design a sound reinforcement system for this interior. First, results of measurements of the parameters of the acoustic field are presented. Then, the comparison between measured and predicted values using the ODEON program is shown. Collected data indicate a long reverberation time which results in poor speech intelligibility. Then, a thorough analysis is perform to improve the acoustic properties of the model of the interior investigated. On the basis of the improved acoustic model two options of a sound reinforcement system for this interior are proposed, and then analyzed. After applying sound absorbing material it was noted that the predicted speech intelligibility increased from bad/poor rating to good category.
Źródło:
Archives of Acoustics; 2016, 41, 3; 473-484
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Occurrence of endoparasitic worms in dusky notothen, Trematomus newnesi (Actinopterygii Nototheniidae), at Adélie Land, Antarctica
Autorzy:
Laskowski, Zdzisław
Rocka, Anna
Zdzitowiecki, Krzysztof
Ozouf-Costaz, Catherine
Powiązania:
https://bibliotekanauki.pl/articles/2051862.pdf
Data publikacji:
2007
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Antarctica
Adélie Land
parasitic worms
fish
Trematomus newnesi
Źródło:
Polish Polar Research; 2007, 1; 37-42
0138-0338
2081-8262
Pojawia się w:
Polish Polar Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A simplified mathematical model of a U-tube steam generator under variable load conditions
Autorzy:
Laskowski, R.
Lewandowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/240139.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
steam generator
mathematical model under variable load conditions
wytwornica pary
model matematyczny
zmienne warunki obciążenia
Opis:
A steam generator in a nuclear power plant with a light water reactor is a heat exchanger, in which the heat is being transferred from the primary to the secondary loop (it links the primary and secondary loops). When the power plant is running, the inlet parameters (temperatures and mass flow rates) on both sides of the steam generator can change. It is important to know how the changes of these parameters affect the steam generator performance. The complexity of the processes taking place in the steam generator makes it difficult to create a simulator reflecting its performance under changed conditions. In order to simplify the task, the steam generator was considered as a ‘black box’ with the aim of examining how the changes of the inlet parameters affect the changes of the outlet ones. On the basis of the system (steam generator) response, a simple mathematical model of the steam generator under variable load conditions was proposed. In the proposed model, there are two dimensionless parameters and three constant coefficients. A linear relation between these dimensionless parameters was obtained. The correctness of the model was verified against the data obtained with a steam generator simulator for European Pressured Reactor and AP-600 reactors. A good agreement between the proposed model and the simulator data was achieved.
Źródło:
Archives of Thermodynamics; 2013, 34, 3; 75-88
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Changes in Digenean Infection of the Antarctic Fish Notothenia Coriiceps in Admiralty Bay, King George Island, Over Three Decades
Autorzy:
Zdzitowiecki, Krzysztof
Laskowski, Zdzisław
Jeżewski, Witold
Powiązania:
https://bibliotekanauki.pl/articles/2051139.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Antarctic
Digenea
black rockcod
Notothenia
change of infection
Źródło:
Polish Polar Research; 2014, 3; 513-520
0138-0338
2081-8262
Pojawia się w:
Polish Polar Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Changes in acanthocephalan infection of the Antarctic fish Notothenia coriiceps in Admiralty Bay, King George Island, over 29 years
Autorzy:
Zdzitowiecki, Krzysztof
Laskowski, Zdzisław
Korczak-Abshire, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/2051465.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Antarctic
Acanthocephala
Admiralty Bay
change of infection
Nototheniacoriiceps
Źródło:
Polish Polar Research; 2012, 1; 99-108
0138-0338
2081-8262
Pojawia się w:
Polish Polar Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determining steam condensation pressure in a power plant condenser in off-design conditions
Autorzy:
Laskowski, Rafał
Smyk, Adam
Ruciński, Adam
Szymczyk, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/1954999.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermal power plant
steam condenser
condenser model
steam condensation
pressure
reference parameters
steam condenser effectiveness
Opis:
The paper presents formulas which can be used to determine steam condensation pressure in a power plant condenser in off-design conditions. The mathematical model provided in the paper makes it possible to calculate the performance of the condenser in terms of condensing steam pressure, cooling water temperature at the condenser outlet, and condenser effectiveness under variable load conditions as a function of three input properties: the temperature and the mass flow rate of cooling water at the condenser inlet and the mass flow rate of steam. The mathematical model takes into account values of properties occurring in reference conditions but it contains no constant coefficients which would have to be established based on data from technical specifications of a condenser or measurement data. Since there are no such constant coefficients, the model of the steam condenser proposed in the paper is universally applicable. The proposed equations were checked against warranty measurements made in the condenser and measurement data gathered during the operation of a 200 MW steam power unit. Based on the analysis, a conclusion may be drawn that the proposed means of determining pressure in a condenser in off-design conditions reflects the condenser performance with sufficient accuracy. This model can be used in optimization and diagnostic analyses of the performance of a power generation unit.
Źródło:
Archives of Thermodynamics; 2021, 42, 3; 45-62
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of a tube diameter in a ‘church window’ condenser based on entropy generation minimization
Autorzy:
Laskowski, R.
Rusowicz, A.
Grzebielec, A.
Powiązania:
https://bibliotekanauki.pl/articles/240523.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
entropy generation minimization
power plant condenser
tube diameter
minimalizacja entropii generacji
skraplacz energetyczny
średnica rurek
Opis:
The internal diameter of a tube in a ‘church window’ condenser was estimated using an entropy generation minimization approach. The adopted model took into account the entropy generation due to heat transfer and flow resistance from the cooling-water side. Calculations were performed considering two equations for the flow resistance coefficient for four different roughness values of a condenser tube. Following the analysis, the internal diameter of the tube was obtained in the range of 17.5 mm to 20 mm (the current internal diameter of the condenser tube is 22 mm). The calculated diameter depends on and is positively related to the roughness assumed in the model.
Źródło:
Archives of Thermodynamics; 2015, 36, 3; 49-59
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies