Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Robustness" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Robust microgrids for distribution systems with high solar photovoltaic penetration
Autorzy:
Sampath, Ediriweera W.E.P.
Lidula, N.W.A.
Herath, H. Dayan B.P.
Powiązania:
https://bibliotekanauki.pl/articles/27309941.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
converter
dynamic system
robustness
stability
synchronous generators
Opis:
A microgrid is an appropriate concept for urban areas with high penetration of renewable power generation, which improves the reliability and efficiency of the distribution network at the consumer premises to meet various loads such as domestic, industrial, and agricultural types. Microgrids comprising inverter-based and synchronous generator-based distribution generators can lead to the instability of the system during the islanded mode of operation. This paper presents a study on designing stable microgrids to facilitate higher penetration of solar power generation into a distribution network. A generalized small signal model is derived for a microgrid with static loads, dynamic loads, energy storages, solar photovoltaic (PV) systems, and diesel generators, incorporating the features of dynamic systems. The model is validated by comparing the transient curves given by the model and a transient simulator subjected to step changes. The result shows that full dynamic models of complex systems of microgrids can be built accurately, and the proposed microgrid is stable for all the considered loading situations and solar PV penetration levels according to the small signal stability analysis.
Źródło:
Archives of Electrical Engineering; 2023, 72, 3; 785--809
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On the robustness of the integrable trajectories of the control systems with limited control resources
Autorzy:
Huseyin, Nesir
Huseyin, Anar
Guseinov, Khalik G.
Powiązania:
https://bibliotekanauki.pl/articles/27321481.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
nonlinear control system
integral equation
integral constraint
integrable trajectory
robustness
Opis:
The control system described by Urysohn type integral equation is considered where the system is nonlinear with respect to the phase vector and is affine with respect to the control vector. The control functions are chosen from the closed ball of the space Lq(Ω; ℝm), q > 1, with radius r and centered at the origin. The trajectory of the system is defined as p-integrable multivariable function from the space Lp(Ω; ℝn), (1/q) + (1/p) = 1, satisfying the system’s equation almost everywhere. It is shown that the system’s trajectories are robust with respect to the fast consumption of the remaining control resource. Applying this result it is proved that every trajectory can be approximated by the trajectory obtained by full consumption of the total control resource.
Źródło:
Archives of Control Sciences; 2023, 33, 3; 527--537
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fractional order PIλDµA controller design based on Bode’s ideal function
Autorzy:
Bettou, Khalfa
Charef, Abdelfatah
Powiązania:
https://bibliotekanauki.pl/articles/27312016.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
Bode’s ideal transfer function
fractional order control
classical PIDA controller
fractional order PIDA controller
robustness
Opis:
The fractional order proportional, integral, derivative and acceleration (PIλDµA) controller is an extension of the classical PIDA controller with real rather than integer integration action order λ and differentiation action order µ. Because the orders λ and µ are real numbers, they will provide more flexibility in the feedback control design for a large range of control systems. The Bode’s ideal transfer function is largely adopted function in fractional control systems because of its iso-damping property which is an essential robustness factor. In this paper an analytical design technique of a fractional order PIλDµA controller is presented to achieve a desired closed loop system whose transfer function is the Bode’s ideal function. In this design method, the values of the six parameters of the fractional order PIλDµA controllers are calculated using only the measured step response of the process to be controlled. Some simulation examples for different third order motor models are presented to illustrate the benefits, the effectiveness and the usefulness of the proposed fractional order PIλDµA controller tuning technique. The simulation results of the closed loop system obtained by the fractional order PIλDµA controller are compared to those obtained by the classical PIDA controller with different design methods found in the literature. The simulation results also show a significant improvement in the closed loop system performances and robustness using the proposed fractional order PIλDµA controller design.
Źródło:
Archives of Control Sciences; 2023, 33, 2; 425--458
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical investigation of steel frame robustness under external sudden column removal
Numeryczna analiza odporności ram stalowych pod nagłym usuwaniem słupa zewnętrznego
Autorzy:
Kozłowski, Aleksander
Kukla, Damian
Powiązania:
https://bibliotekanauki.pl/articles/27312138.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
analiza dynamiczna
konstrukcja ramowa
usunięcie słupa
ocena odporności
połączenie śrubowe stalowe
słup zewnętrzny
dynamic analysis
external column
column loss
framed structure
robustness assessment
steel bolted joint
Opis:
Numerical analysis of robustness assessment of steel planar framed structures under sudden external column removal is presented. The analysis is based on the previous experimental and numerical analyzes conducted in the Ph.D. project. Advanced and validated finite element models of steel structures with bolted end plate joints were used using Abaqus software. Six different cases of analysis using flush and extended bolted end-plate joints were performed. The actual results of the axial forces and rotations of the joints, failure models, and other important factors about structure behaviour are presented. The clear division of the results obtained depended on the type of joint used in the structure. In the cases of application of extended end-plate joints in frame analysis, the required level of robustness was reached in all cases and stopping of collapse development was obtained. In all cases of frame analysis with flush end-plate joints, an insufficient level of robustness on progressive collapse was obtained and partial failures of the structures were reached. Due to the location of the external column, the catenary actions to mitigate progressive collapse were very limited.
Przedstawiono analizę numeryczną oceny odporności stalowych płaskich konstrukcji ramowych pod wpływem nagłego usunięcia słupa zewnętrznego. Przeprowadzono analizy w oparciu o wcześniejsze badania eksperymentalne i analizy numeryczne przeprowadzone w ramach pracy doktorskiej pierwszego autora. Wykorzystano zaawansowane i zwalidowane modele elementów skończonych konstrukcji stalowej z połączeniami śrubowymi z blachą czołową przy użyciu oprogramowania Abaqus. Przeprowadzono sześć różnych przypadków analizy, w których zastosowano połączenia śrubowe doczołowe z blachą wpuszczoną i wystającą. Przedstawiono dokładne wyniki sił osiowych i obrotów połączeń, modele zniszczenia i inne ważne czynniki dotyczące zachowania konstrukcji. Wyraźny podział otrzymanych wyników zależny jest od rodzaju zastosowanego węzła w konstrukcji. W przypadku zastosowania w analizie ram połączeń doczołowych z blachą wystającą, we wszystkich przypadkach osiągnięto wymagany poziom odporności i zatrzymano rozwój katastrofy. We wszystkich przypadkach analizy ram z połączeniami doczołowymi z blachą wpuszczoną uzyskano niewystarczający poziom odporności na postępującą katastrofę i obserwowano częściowe uszkodzenia konstrukcji. Ze względu na usytuowanie słupa zewnętrznego działanie akcji cięgnowej mające na celu złagodzenie postępującego zawalenia było znacznie ograniczone. Na koniec przedstawiono zalecenia dotyczące kształtowania doczołowych połączeń śrubowych w celu zwiększenia odporności konstrukcji.
Źródło:
Archives of Civil Engineering; 2023, 69, 2; 177--193
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies