Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Wang, Yi" wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
The Cellular Traffic Capacity Model of Toll Station Square
Autorzy:
Bai, Yuning
Wang, Kaixuan
Yi, Lei
Peng, Bo
Powiązania:
https://bibliotekanauki.pl/articles/27311807.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
highway toll station
traffic capacity
microscopic simulation
toll plaza
opłata autostradowa
punkt poboru opłaty
natężenie ruchu
Opis:
Traffic capacity is an important index to measure the operation efficiency of expressway toll stations. In order to provide relevant theoretical support for accurately evaluating the congestion degree and service level of toll stations, this paper establishes a traffic capacity calculation model for the square in front of expressway toll stations based on the traditional cellular transmission method. Firstly, by dividing the square in front of the station into regular cells, the process of calculating the traffic capacity is simplified; Secondly, the capacity model of the square in front of the station is established based on cellular transmission, and a large amount of data is collected through the monitoring videos of several toll stations. The theoretical capacity of the square in front of the station is calculated by using the important parameters of the model calibrated by the measured data under different lengths of the square in front of the station and the configuration of toll lanes. Then, the simulation platform of VISSIM software is used, and many experiments are carried out with relevant measured data to verify the accuracy of the model in multiple scenarios. Finally, the simulation value of the capacity of the square in front of the station is obtained, and the error is calculated by using the simulation value and the calculation value. The results show that the error of the verification result is 5.19%, and the error is within the allowable range, which shows that the model is accurate and feasible. The theoretical capacity calculated by the capacity model of the square in front of the toll station established in this paper is compared with the actual capacity, which can be used as a standard to judge the congestion degree of the square in front of the toll station and further provide a theoretical reference for evacuation of congestion.
Źródło:
Archives of Transport; 2023, 67, 3; 35--47
0866-9546
2300-8830
Pojawia się w:
Archives of Transport
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of combined gap in whole process of transmission lines’ live working based on 3D laser point cloud
Autorzy:
Wang, Ying
Zhang, Haitao
Lv, Qiang
Gao, Qiang
Yi, Mingxing
Powiązania:
https://bibliotekanauki.pl/articles/27309938.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
3D model
combined gap
laser point cloud
live working
transmission lines
Opis:
Transmission lines’ live working is one of an effective means to ensure the reliable operation of transmission lines. In order to solve the unsafe problems existing in the implementation of traditional live working, the paper uses ground-based lidar to collect point cloud data. A tile based on the pyramid data structure is proposed to complete the storage and calling of point cloud data. The improved bidirectional filtering algorithm is used to distinguish surface features quickly and obtain a 3D model of the site. Considering the characteristics of live working, the speed of data reading and querying, the nearest point search algorithm based on octree is used to acquire a real- time calculation of the safe distance of each point in the planned path, and the safety of the operation mode is obtained by comparing with the value specified in the regulation, and assist in making decisions of the operation plan. In the paper, the simulation of the actual working condition is carried out by taking the “the electric lifting device ascending” as an example. The experimental results show that the established three-dimensional model can meet the whole process control of the operation, and has achieved practical effect.
Źródło:
Archives of Electrical Engineering; 2023, 72, 3; 737--753
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies