Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "fault-arc" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Location of arc faults on power transmission lines
Autorzy:
Pustułka, M
Iżykowski, J
Łukowicz, M
Powiązania:
https://bibliotekanauki.pl/articles/410527.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
arc fault
fault location
signal processing
Opis:
This paper presents a fault location algorithm, which allows to determine the distance to a fault and fault resistance, as a result of considering natural fault loops. It is assumed that three-phase voltages and currents from both ends of the line measured asynchronously are the input signals of the fault locator. In case of the availability of synchronized measurements the elements associated with the determination of the synchronization angle should be omitted. In addition to natural fault loop signals also use of symmetrical components (positive and negative or incremental positive sequence components) to fault location were considered as well.
Źródło:
Present Problems of Power System Control; 2013, 3; s. 95-102
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Neural network filtration for arc faults location on power transmission lines
Autorzy:
Pustułka, M.
Iżykowski, J.
Łukowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/410589.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
arc fault
fault location
signal processing
filtration
Opis:
This paper presents filtration using neural network for arc fault location, which allows to determine the distance to a fault, as a result of considering natural fault loops. It is assumed that three-phase voltages and currents from both ends of the line are the input signals of the fault locator and naturally of the neutral network applied for filtering the input signals. In addition to natural fault loop signals also use of symmetrical components (positive and negative or incremental positive sequence components) to fault location were considered as well. Results of evaluation study have been included, analyzed and discussed. Influence of filtration has been also considered.
Źródło:
Present Problems of Power System Control; 2013, 4; 37-49
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies