Tytuł:
Analysis of the structure of liners used for the modernisation of brick collectors
Autorzy:
Wysocki, Leszek
Madryas, Cezary
Grosel, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/2037687.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
brick sewer
renovation
CIPP liner
modernization of brick sewers
Opis:
Brick sewers were designed as egg-shaped, pear-shaped, bell-shaped, vaulted, and even rectangular (sometimes with granite ceilings and floor slabs). In exceptional cases, circular sections were also made of brick. Efforts were made in order to ensure optimal flow conditions, and also that the cross-section was adapted to the shape of the rock mass pressure line. This is due to the fact that the most advantageous shapes for masonry collectors are shapes in which no tensile stresses will occur in any part of the cross-section under the influence of external loads. Nevertheless, sewage conduits degrade over time. The boundary conditions of their use also change, which affects the magnitude of mechanical and hydraulic loads. Further use of a sewer in such a case requires its renewal, and less frequently, modernization that results from the necessity to change its function. This is usually done by introducing a new conduit into the interior of the renovated or modernized sewer, which in literature is called a liner. The aim of the analysis was to determine the thickness of the liners that strengthen the structures of brick channels with an inverted egg cross-section and with dimensions of 1050 × 700 mm, which are intended for gravitational sewage systems. The analysis included the performance of variant static and strength calculations for the assumption that the conduit after its modernization will be replaced with a conduit operating in the pressure system, which is a very rare requirement. It was assumed that the best solution would be to use a CIPP (Cured In Place Pipe) liner.
Źródło:
Studia Geotechnica et Mechanica; 2021, 43, s1; 501-509
0137-6365
2083-831X
Pojawia się w:
Studia Geotechnica et Mechanica
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies