Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Yu, Q." wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
Converged ultra-wideband and multi-level wired signal downstream transport over single wavelength in wavelength-division multiplexing passive optical network
Autorzy:
Ma, H
Wang, F.
Wang, W.
Zhang, X
Yu, Q.
Powiązania:
https://bibliotekanauki.pl/articles/174929.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ultra-wideband (UWB)
multi-level amplitude switch keying (M-ASK)
wavelength-division multiplexing passive optical network (WDM-PON)
Opis:
Simultaneous providing services of ultra-wideband and wired signal over single wavelength can greatly decrease the complexity and reduce the costs of a wavelength-division multiplexing passive optical network. However, ultra-wideband signal occupies the spectrum range from 3.1 to 10.6 GHz, and a narrow idle frequency band (from 0 to 3.1 GHz) could be employed to transport wired signal with a limited rate. In this paper, we proposed a scheme to simultaneously provide ultra-wideband and wired services, in which the information rate of the wired signal is enhanced by employing a multi-level amplitude switch keying signal in the idle frequency band formed by ultra-wideband signal. In comparison with other advanced modulation formats used for wavelength-division multiplexing passive optical networks such as orthogonal frequency division multiplexing, multi-level amplitude switch keying signal can be easily received by using intensity modulation direct detection, which will greatly reduce the cost of end-users. Especially, if a multi-band ultra-wideband signal is substituted for the direct-sequence ultra-wideband signal, the available spectrum range to transport wired signal will be easily extended to 5 GHz as multi-band ultra-wideband signal has a narrower spectrum width and flexible center frequency, so 4-amplitude switch keying signal with a rate of 5 Gbaud will achieve an information rate of 10 Gbit/s.
Źródło:
Optica Applicata; 2015, 45, 4; 433-445
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Image encryption combining discrete fractional angular transform with Arnold transform in image bit planes
Autorzy:
Zhou, Z.
Yu, J.
Liao, Q.
Gong, L.
Powiązania:
https://bibliotekanauki.pl/articles/173704.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
Arnold transform
bit plane
discrete fractional angular transform
image encryption algorithm
Opis:
A new image encryption algorithm by using a discrete fractional angular transform and Arnold transform in image bit planes is investigated. In the image encryption algorithm, the original image is encrypted by the Arnold transform in image bit planes firstly, and then the resulting image is encrypted by the discrete fractional angular transform further. The key of the image encryption algorithm includes the parameters of the Arnold transform and the order of the discrete fractional angular transform. It is shown that the proposed image encryption algorithm is of high security and strong enough to counteract some conventional image attack manners.
Źródło:
Optica Applicata; 2018, 48, 2; 225-236
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Plantar pressure analysis of above-knee amputee with a developed microprocessor-controlled prosthetic knee
Autorzy:
Cao, W.
Yu, H.
Meng, Q.
Li, S.
Powiązania:
https://bibliotekanauki.pl/articles/306983.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ciśnienie podeszwowe
proteza stawu kolanowego
analiza chodu
plantar pressure
above-knee amputee
microprocessor-controlled
prosthetic knee
gait analysis
Opis:
Human gait motion analysis was one useful method for lower limb prosthesis study. The most often measured parameters were plantar pressure, kinetic and kinematic parameters. It was indispensable for prosthetic knee design and performance assessment. The aim of this study was to analysis the plantar pressure in traumatic above-knee amputee equipped with a developed microprocessor-controlled prosthetic knee. Methods: The maximum force of forefoot and rearfoot, the average vertical reaction force and pressure and the centre of pressure (COP) offset trajectories of ten above-knee amputees under different walking speeds were obtained. Results: Both forefoot and rearfoot force were bigger in intact leg than prosthetic leg. As the speed increased, the pressure increased in both sides. Forefoot bore more pressure than rearfoot in both legs. The average vertical pressure and force both increased along with the increase of speed. The force and pressure of intact side were always bigger than the prosthetic side. The trend of COP and gait line of the prosthetic and intact side had no significant difference. The length of the gait line of prosthetic side was greater than the intact side. Conclusions: The results of this study exhibited reduced plantar pressure in the prosthetic side. The typical butterfly diagrams were produced during different walking speeds. It indicated that the stability of the microprocessor-controlled prosthetic knee could be guaranteed.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 4; 33-40
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fiber-optic accelerometer based on a modal interferometer using a thin-core fiber
Autorzy:
Wang, X
Wu, X
Li, S
Ge, Q
He, T
Yu, B
Powiązania:
https://bibliotekanauki.pl/articles/174927.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
fiber-optic accelerometer
modal interferometer
thin-core fiber
Opis:
A compact fiber-optic accelerometer based on a modal interferometer, which is fabricated by misaligned splicing of a short section of a thin-core fiber between two sections of a standard single-mode fiber, is demonstrated experimentally. A spectrum analysis method is used to detect an acceleration signal rapidly. The experimental results show that the thin-core fiber-based fiber-optic accelerometer has a minimum detectable acceleration of 3.3×10–3g (g – gravitational acceleration), and a wide frequency response range from 10 to 1200 Hz. Moreover, the proposed accelerometer exhibits the advantages of low cost, simple structure and easy fabrication.
Źródło:
Optica Applicata; 2015, 45, 3; 317-325
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of the microcrack shape, size and direction on the poroelastic behaviors of a single osteon: a finite element study
Autorzy:
Cen, H-P.
Wu, X-G.
Yu, W-L.
Liu, Q-Z.
Yia, Y-M.
Powiązania:
https://bibliotekanauki.pl/articles/306642.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
poroelastyczność
mikropęknięcie
elementy skończone
osteon
poroelasticity
microcrack
finite element
Opis:
In this work, a finite element study is proposed by using the Comsol Multiphysics software to evaluate the effects of microcrack shape, size and direction on the poroelastic behaviors of a single osteon. Methods: This finite element model is established by using the Comsol Multiphysics software, and we just focus on the comparison of the influences of those microcrack geometric parameters on the osteonal fluid pressure and velocity. Results: The results show that: (1) microcracks in the osteon wall can induce a release of the fluid pressure, but enlarge the velocity in this region; (2) equal-area microcrack with ellipsoid-like shape produced a larger fluid pressure and velocity fields in the osteon than that of rectangular shape; (3) in the elliptic microcracks, the longer of the length (major semi-axis) induces a smaller fluid pressure and velocity amplitudes, whereas the width (minor axis) has little effect; (4) the direction of the microcracks (major axial direction) has an limited influence area around about 1/15 of the osteon cross-sectional area. Conclusions: This model permits the linking of the external loads and microcracks to the osteonal fluid pressure and velocity, which can be used for other purpose associate microcracks with the mechanotransduction and bone remodeling.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 1; 3-10
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies