Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Szajek, K." wg kryterium: Autor


Wyświetlanie 1-1 z 1
Tytuł:
Numerical verification of two-component dental implant in the context of fatigue life for various load cases
Autorzy:
Szajek, K.
Wierszycki, M.
Powiązania:
https://bibliotekanauki.pl/articles/307214.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
implant stomatologiczny
optymalizacja
trwałość zmęczeniowa
algorytm genetyczny
dental implant
optimization
fatigue life
genetic algorithm
Opis:
Purpose: Dental implant designing is a complex process which considers many limitations both biological and mechanical in nature. In earlier studies, a complete procedure for improvement of two-component dental implant was proposed. However, the optimization tasks carried out required assumption on representative load case, which raised doubts on optimality for the other load cases. This paper deals with verification of the optimal design in context of fatigue life and its main goal is to answer the question if the assumed load scenario (solely horizontal occlusal load) leads to the design which is also “safe” for oblique occlussal loads regardless the angle from an implant axis. Methods: The verification is carried out with series of finite element analyses for wide spectrum of physiologically justified loads. The design of experiment methodology with full factorial technique is utilized. All computations are done in Abaqus suite. Results: The maximal Mises stress and normalized effective stress amplitude for various load cases are discussed and compared with the assumed “safe” limit (equivalent of fatigue life for 5e6 cycles). Conclusions: The obtained results proof that coronial-appical load component should be taken into consideration in the two component dental implant when fatigue life is optimized. However, its influence in the analyzed case is small and does not change the fact that the fatigue life improvement is observed for all components within whole range of analyzed loads.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 1; 103-113
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies