Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Reszka, E." wg kryterium: Autor


Wyświetlanie 1-1 z 1
Tytuł:
Structure and corrosion resistance of Co-Cr-Mo alloy used in Birmingham Hip Resurfacing system
Autorzy:
Dobruchowska, E.
Paziewska, M.
Przybyl, K.
Reszka, K.
Powiązania:
https://bibliotekanauki.pl/articles/306647.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
stopy kobaltu
stopy chromu
stopy molibdenu
karbid
odporność korozyjna
polaryzacja potencjodynamiczna
stal nierdzewna
stal azotowana
cobalt-chromium-molybdenum alloy
Birmingham Hip Resurfacing
carbide
precipitation
corrosion resistance
potentiodynamic polarisation
nitrided stainless steel
Opis:
The endoprostheses made of cobalt-chromium-molybdenum (Co-Cr-Mo) alloys belong to the group of the most popular metallic implants used for hip joints reconstruction. For such biomaterials, the primary goal is correct and long-term functioning in the aggressive environment of body fluids. Therefore, the purpose of this study was to examine both the morphology and the corrosion resistance of implants made of the cobalt alloy used in Birmingham Hip Resurfacing (BHR) system (Smith & Nephew). For comparative purposes, the electrochemical studies were done for the nitrided stainless steel – Orthinox. Methods: Observations of the microstructure of the investigated material were performed by means of the optical metallographic microscope and the scanning electron microscope. Furthermore, Energy Dispersive X-ray Spectroscopy was used to analyse the chemical composition of the endoprosthesis. Characterisation and evaluation of electrochemical corrosion resistance of the selected alloys were performed by potentiodynamic polarisation tests. Results: The structural studies confirmed that Co-Cr-Mo (BHR system) is characterised by a typical dendritic microstructure with carbide precipitates, mainly M23C6, within the interdendritic areas. Results of the polarisation measurements showed that the investigated cobalt alloy exhibits lower corrosion potential than Orthinox in the utilised environments (3% NaCl, simulated body fluid – Hank’s Body Fluid). Conclusions: However, the high passivation ability of the Co-Cr-Mo alloy, as well as its resistance to the initiation and propagation of localised corrosion processes, indicate that this material is significantly more appropriate for long-term implants.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 2; 31-39
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies