Tytuł:
Pullout evaluation of sawbone experiment in different types of pedicle screws combined with bone cement augmentation for severe osteoporotic spine
Autorzy:
Yang, S.-C.
Liu, P.-H.
Tu, Y.-K.
Powiązania:
https://bibliotekanauki.pl/articles/307271.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
osteoporoza
kości
wytrzymałość
osteoporosis
bone cement augmentation
cannulated pedicle screw
sawbone
pullout strength
Opis:
Purpose: The conventional screw is unable to provide enough screw-bone interface strength for osteoporotic cencellous bone, and complications resulting from loosening or failure of the implants remain a significant clinical problem. Hence, the purpose of this study is to investigate pullout strength and energy in three types of the pedicle screws, including conventional solid pedicle screw, cannulated pedicle screw, and cannulated pedicle screw with a central pin, using osteoporotic sawbone test block with different bone cement volumes through pullout force testing. Methods: The control group (n = 15) of the osteoporotic sawbone test block includes groups A, B, and C to reflect three types of the pedicle screws without bone cement augmentation. The cemented group (n = 45) of the osteoporotic sawbone test block includes groups D1, D2, D3, E1, E2, E3, F1, F2, and F3 to reflect three types of the pedicle screws with PMMA bone cement of 2, 3, and 4 mL augmentation. Results: The results showed that the pullout strength and energy in the cemented group were significantly larger than that in the control group. Moreover, the best performances of the pullout strength and energy in the cemented group were evidenced obviously in the case of cannulated pedicle screw with a central pin with 4 mL bone cement augmentation. Conclusions: This study concludes that cement argumentation in the cannulated pedicle screw with a central pin can increase a pullout strength of pedicle screw for severe osteoporotic patients while bone cement of injective volume is limited.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 2; 55-64
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Theoretical analysis of a hollow laser beam transmitting in an off-axis Cassegrain optical antenna system
Autorzy:
Mi, C
Jiang, P
Yang, H.
Ke, S
Li, B
Liu, J.
Powiązania:
https://bibliotekanauki.pl/articles/174358.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
Cassegrain optical antenna
off-axis hollow laser beam
receiving efficiency
Opis:
The optical model of a Cassegrain optical antenna with a confocal double-parabolic reflector structure has been designed, and the propagation characteristics of a hollow laser beam, which could avoid the loss of energy caused by the subreflector center reflection in the optical antenna, has been researched in this paper. By detailed analysis and numerical calculations of a receiving Cassegrain antenna with different deflection angles, the coupling efficiency curve and 3-D distributions of the receiving light intensity for different inclined angles have been obtained.
Źródło:
Optica Applicata; 2014, 44, 3; 421-431
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sensitive detection of acetylene by second derivative spectra with tunable diode laser absorption spectroscopy
Autorzy:
Deng, H.
Sun, J.
Li, P.
Liu, Y.
Yu, B.
Li, J.
Powiązania:
https://bibliotekanauki.pl/articles/174963.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
tunable diode laser absorption spectroscopy
TDLAS
signal processing
Savitzky–Golay filter
trace gas detection
Opis:
A tunable diode laser absorption spectrometer was developed for trace acetylene gas analysis, the system performance was evaluated by combing an appropriate digital signal processing methods, i.e., Savitzky–Golay smoothing and differentiation algorithm. The calculation of the derivative spectra by this method is accompanied by simultaneous data smoothing. Based on the 2nd deriv- ative spectra detection method, the Allan variance technique indicates a C2H2 detection limit of 1.7ppm for 1-s averaging time, and a minimum noise level of 62ppb (parts per billion), at the optimum integration time of ~60s. The calculated 2nd derivative spectra with better resolution, lower detection limits, save signal processing time, and improve the ability to distinguish unresolved spectral signals.
Źródło:
Optica Applicata; 2016, 46, 3; 353-363
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of the microcrack shape, size and direction on the poroelastic behaviors of a single osteon: a finite element study
Autorzy:
Cen, H-P.
Wu, X-G.
Yu, W-L.
Liu, Q-Z.
Yia, Y-M.
Powiązania:
https://bibliotekanauki.pl/articles/306642.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
poroelastyczność
mikropęknięcie
elementy skończone
osteon
poroelasticity
microcrack
finite element
Opis:
In this work, a finite element study is proposed by using the Comsol Multiphysics software to evaluate the effects of microcrack shape, size and direction on the poroelastic behaviors of a single osteon. Methods: This finite element model is established by using the Comsol Multiphysics software, and we just focus on the comparison of the influences of those microcrack geometric parameters on the osteonal fluid pressure and velocity. Results: The results show that: (1) microcracks in the osteon wall can induce a release of the fluid pressure, but enlarge the velocity in this region; (2) equal-area microcrack with ellipsoid-like shape produced a larger fluid pressure and velocity fields in the osteon than that of rectangular shape; (3) in the elliptic microcracks, the longer of the length (major semi-axis) induces a smaller fluid pressure and velocity amplitudes, whereas the width (minor axis) has little effect; (4) the direction of the microcracks (major axial direction) has an limited influence area around about 1/15 of the osteon cross-sectional area. Conclusions: This model permits the linking of the external loads and microcracks to the osteonal fluid pressure and velocity, which can be used for other purpose associate microcracks with the mechanotransduction and bone remodeling.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 1; 3-10
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies