Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "L.N." wg kryterium: Autor


Tytuł:
Fiber Bragg grating-based high temperature sensor and its low cost interrogation system with enhanced resolution
Autorzy:
Mamidi, V R
Kamineni, S
Ravinuthala, L N S P
Madhuvarasu, S S
Thumu, V R
Pachava, V R
Putha, K
Powiązania:
https://bibliotekanauki.pl/articles/949414.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
fiber Bragg grating (FBG)
long period grating
fiber optic temperature sensor
optical intensity modulation
Opis:
A fiber Brag grating-based high temperature sensor together with a low cost, high speed and compact size interrogation system using a long period grating was designed, developed and tested. The designed sensor measures the temperature from room temperature to 550 °C. The sensor head was configured by encapsulating an fiber Brag grating (type-I) of Bragg resonance wavelength at 1552.88 nm in a capillary tube made of copper. Long period grating with peak transmission loss at 1550 nm was employed to convert the wavelength information from fiber Brag grating into an intensity modulated signal. Temperature related optical intensity information was again converted into its equivalent electrical signal by using a photodiode. The achieved resolution of the sensor was found to be 0.5 °C.
Źródło:
Optica Applicata; 2014, 44, 2; 299-308
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Deep compaction control of sandy soils
Autorzy:
Bałachowski, L.
Kurek, N.
Powiązania:
https://bibliotekanauki.pl/articles/178341.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
vibrocompaction
CPTU
sands
soil behaviour type
piaski
gleby piaszczyste
zagęszczanie wibracyjne
Opis:
Vibroflotation, vibratory compaction, micro-blasting or heavy tamping are typical improvement methods for the cohesionless deposits of high thickness. The complex mechanism of deep soil compaction is related to void ratio decrease with grain rear-rangements, lateral stress increase, prestressing effect of certain number of load cycles, water pressure dissipation, aging and other effects. Calibration chamber based interpretation of CPTU/DMT can be used to take into account vertical and horizontal stress and void ratio effects. Some examples of interpretation of soundings in pre-treated and compacted sands are given. Some acceptance criteria for compaction control are discussed. The improvement factors are analysed including the normalised approach based on the soil behaviour type index.
Źródło:
Studia Geotechnica et Mechanica; 2014, 36, 2; 3-8
0137-6365
2083-831X
Pojawia się w:
Studia Geotechnica et Mechanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nanoblocks embedded in L-shaped nanocavity of a plasmonic sensor for best sensor performance
Autorzy:
Butt, M. A.
Kazanskiy, N. L.
Powiązania:
https://bibliotekanauki.pl/articles/1835766.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
plasmonic sensor
refractive index sensor
metal-insulator-metal waveguide
L-shaped cavity
finite element method
Opis:
In this work, we proposed a highly sensitive design of a plasmonic sensor which is formed by embedding a periodic array of nanoblocks in L-shaped cavity formed by the metal–insulator–metal waveguide. The nanoblocks are placed in the strong electric field confinement region to further enhance its strength by confining it to a small area. To validate the study, the spectral characteristics of the proposed sensor design is compared to the spectral characteristics of a standard design having the same geometric parameters excluding nanoblocks in the cavity. The study shows that the incorporation of 5 nanoblocks of length 25 nm in the cavity can provide best performance indicators in the form of sensitivity, figure of merit and Q-factor. The sensitivity, figure of merit and Q-factor of the proposed sensor design is 1065 nm/RIU, 251.17 and 343.4 which is significantly higher than the standard L-shape resonator design. The sensor design can be developed with a single fabrication step. Due to the ease of fabrication and the highly responsive nature of the design, it can be used in biomedical applications.
Źródło:
Optica Applicata; 2021, 51, 1; 109-120
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biomechanics of the shoulder girdle : a case study on the effects of union rugby tackles
Autorzy:
Faria, L.
Campos, B.
Jorge, R. N.
Powiązania:
https://bibliotekanauki.pl/articles/307526.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
bark
dynamometr
izokinetyka
sEMG
shoulder
rotator cuff
pressure sensors
force plate
isokinetic dynamometer
Opis:
Purpose: The shoulder girdle is a complex system, comprised by a kinematic chain and stabilizers. Due to the delicate equilibrium and synchronism between mobility and stability, high external loads may compromise its physiology, increasing the risk of injuries. Thus, this study intends to fully characterize the effects of a rugby tackle on the shoulder’s anatomy and physiology. Methods: For the experimental procedures, a matrix of pressure sensors was used, based on the Teckscan® pressure in-soles, force plates, an isokinetic dynamometer and sEMG (surface electromyography). Results: The anterosuperior region of the shoulder girdle confirmed the highest pressure values during impact (100 kPa to 200 kPa). Also, the right and left feet performed a vertical peak force of 1286 N (1.4 BW) and 1998 N (2.21 BW), respectively. The muscular activity of the shoulder muscles decreased after performing multiple tackles. Conclusions: During a tackle, the clavicle, scapula, trapezius and acromioclavicular joint are the anatomical structures with higher risk of injury. Also, the strike force on the feet decreases for stability purposes. After performing multiple impacts the muscular activity of the trapezius and rotator cuff muscles decreases, which may lead, in the long-term, to instability of the shoulder and inefficiency of the scapulohumeral rhythm.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 3; 115-127
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nano-silica reinforced hybrid light-diffusing films with enhanced mechanical and thermal properties
Autorzy:
Sun, X
Li, N.
Hang, J
Jin, L.
Shi, L
Cheng, Z.
Shang, D
Powiązania:
https://bibliotekanauki.pl/articles/175043.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
optical materials and properties
nanocomposites
light-diffusing films
sol-gel preparation
nanoparticles
Opis:
Ultraviolet-curable hybrid light-diffusing films with good optical, mechanical and thermal properties were prepared by involving vinyl-silane-modified nano-silica into light-diffusing films. The light-diffusing films were two-phase materials consisting of UV-curable matrix and light-diffusing agent. The effect of three different light-diffusing agents, viz. inorganic layered particle (CaCO3), spherical acrylic resin (MR-7HG) and organosilicone resin (KMP-590) and their contents, on the optical properties of light-diffusing films was studied. The results showed the light-diffusing film exhibited good optical properties (the transmittance was 90.7% and the haze was 95.5%) when KMP-590 was a light-diffusing agent and its content was 25%. It was because that KMP-590 showed good transparency, good dispersion in the UV-curable matrix and the greater difference in refractive index with UV-curable matrix and polycarbonate substrate. Furthermore, the effect of nano-silica on the optical, mechanical and thermal properties of the hybrid light-diffusing films was investigated. Compared to that of the light-diffusing films without nano-silica, the haze of the hybrid light-diffusing films containing nano-silica was lightly enhanced to above 98%, while their transmittance basically remained unchanged at a high value (above 89%). Additionally, scratch and abrasion resistance of the hybrid films were obviously improved by nano-silica especially with the particle size of 10–15 nm. Furthermore, the mechanical property and thermal stability of the hybrid films were improved as the content of nano-silica with the particle size of 10–15 nm increased. The enhanced mechanical property and thermal stability of the films could be attributed to the dense structure induced by the increase in network density with the addition of vinyl-silane-modified nano-silica.
Źródło:
Optica Applicata; 2015, 45, 3; 393-404
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanical properties variation and constitutive modelling of biomedical polymers after sterilization
Autorzy:
Zanelli, L.
Todros, S.
Carniel, E. L.
Pavan, P. G.
Natali, A. N.
Powiązania:
https://bibliotekanauki.pl/articles/307365.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
sterylizacja
właściwości sprężyste
model konstytutywny
polimery biokompatybilne
sterilization
elasto-plastic behavior
constitutive model
biocompatible polymers
elastic properties
biomedical device
Opis:
Purpose: In this work, the mechanical behavior of two block copolymers for biomedical applications is studied with particular regard to the effects induced by a steam sterilization treatment that biomedical devices usually undergo in healthcare facilities. This investigation is aimed at describing the elasto-plastic behavior of the stress-strain response, determining a functional dependence between material constitutive parameters, to obtain an optimal constitutive model. Methods: The mechanical properties of these polymers are analyzed through uniaxial tensile tests, before and after the sterilization process. The effect of sterilization on the mechanical behavior is evaluated. The Ramberg-Osgood model is used to describe the elasto-plastic behavior of the stress-strain response. Results: Data from uniaxial tensile tests are discussed in the light of previous data on the same polymeric materials, in order to highlight the correlation between physicochemical and mechanical properties variation. The material constitutive parameters are determined and the functional dependence between them is found, thus enabling an optimal constitutive model to be obtained. Conclusions: The effect of sterilization on the material constitutive parameters is studied, to evaluate the suitability of the model in describing the mechanical response of biomedical polymer before and after sterilization treatment. The same approach can be applied to other biomaterials, under various tensile tests, and for several processes that induce variation in mechanical properties.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 3; 3-9
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Water film structure during rupture as revealed by MDS image analysis
Autorzy:
Truong, N. T.
Dang, L. X.
Lin, C.-L.
Wang, X.
Miller, J. D.
Powiązania:
https://bibliotekanauki.pl/articles/110251.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
image processing
molecular dynamics simulation
film stability
molecular porosity
Opis:
The structure of thin water films during the rupture process was investigated by a new approach, which combines molecular dynamics simulation (MDS) with image processing analysis. The analysis procedure was developed to convert MDS trajectories to readable 3D images. The water films were studied at different thicknesses by MDS to determine the critical thickness at which the film ruptures. The potential energy of each specific film thickness during the simulation time was analyzed, and the results showed that the potential energy of stable films remained unchanged while the potential energy kept decreasing for films which ruptured during the simulation time. By applying the new procedure, the molecular porosity, which is defined as the void fraction between the volume of molecular pores in the water film and the total volume of the water film, was calculated. The results of molecular porosity for different film thicknesses during the simulation time suggested a critical molecular porosity as 49%. In other words, stable films have a molecular porosity of less than 49%. If a water film has a molecular porosity greater than 49%, rupture occurs during the simulation.
Źródło:
Physicochemical Problems of Mineral Processing; 2018, 54, 4; 1060-1069
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A longitudinal assessment of myoelectric activity, postural sway, and low-back pain during pregnancy
Autorzy:
Moreira, L. S.
Elias, L. A.
Gomide, A. B.
Vieira, M. F.
Do Amaral, W. N.
Powiązania:
https://bibliotekanauki.pl/articles/307463.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
elektromiografia
stabilność postawy
bóle kręgosłupa
electromyography
low back pain
postural balance
pregnancy trimesters
stabilometry
Opis:
The present study aimed at investigating the control of upright quiet standing in pregnant women throughout pregnancy, and whether low-back pain exerts influence on this motor task. Methods: Myoelectric signals from postural muscles and stabilometric data were collected from 15 non-pregnant and 15 pregnant women during upright quiet standing. Electromyogram envelopes and center of pressure metrics were evaluated in the control group, as well as in pregnant women in their first and third trimester of pregnancy. A correlation analysis was performed between the measured variables and a low-back pain disability index. Results: Pregnant women exhibited a decreased maximum voluntary isometric activity for all postural muscles evaluated. Additionally, the activity of lumbar muscles during the postural task was significantly higher in the pregnant women in comparison to the non-pregnant controls. The soleus muscle maintained its activity at the same level as the gestation progressed. Higher postural oscillations were observed in the anteroposterior direction while mediolateral sway was reduced in the third trimester of pregnancy. No correlation was detected between the lowback pain disability index and neuromechanical variables. Conclusion: This study provides additional data regarding the functioning and adaptations of the postural control system during pregnancy. Also, we provide further evidence that postural control during quiet standing cannot be used to predict the occurrence of low-back pain. We hypothesize that the modifications in the neural drive to the muscles, as well as in postural sway may be related to changes in the biomechanics and hormonal levels experienced by the pregnant women.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 3; 77-83
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The differences between overground and treadmill walking in nonlinear, entropy-based and frequency variables derived from accelerometers in young and older women : preliminary report
Autorzy:
Bizovska, L.
Svoboda, Z.
Kubonova, E.
Vuillerme, N.
Hirjakova, Z.
Janura, M.
Powiązania:
https://bibliotekanauki.pl/articles/307504.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
starzenie
chód
stabilność
stateczność dynamiczna
ageing
gait
stability
variability
local dynamic stability
Opis:
The aim of this study was to compare gait stability and variability between walking conditions and age groups. Methods: Twenty-six healthy younger and older females participated. Trunk acceleration in the vertical (V), medial-lateral (ML) and anteriorposterior (AP) directions during 5 minutes walking overground and 3 minutes walking on the treadmill at self-selected speed were recorded. Root mean square and standard deviations of acceleration, stride time and its variability, Lyapunov exponents (LE), multiscale entropy (MSE) and harmonic ratios (HR) were computed. Results: Both age groups showed significantly higher stride time variability and short-term LE in all directions during overground walking. For the older group, overground walking showed higher V and AP standard deviation. Significantly lower values for overground walking were observed for long-term LE (V and ML for the younger group, ML for the older group), HR (ML for the older group) and MSE (V for the older group). Significant age-related differences were found for V long-term LE for overground walking. Conclusions: The present findings suggest that both linear and advanced computational techniques for gait stability and variability assessment in older adults are sensitive to walking conditions.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 1; 93-100
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Generating Graphical User Interfaces from Precise Domain Specifications
Autorzy:
Rybinski, K
Jarzebowski, N
Smiałek, M
Nowakowski, W.
Skrzypek, L.
Łabecki, P
Powiązania:
https://bibliotekanauki.pl/articles/384184.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
Precise Domain Specifications
generating code
working systems
user interface elements
Opis:
Turning requirements into working systems is the essence of software engineering. This paper proposes automation of one of the aspects of this vast problem: generating user interfaces directly from requirements models. It presents syntax and semantics of a comprehensible yet precise domain specification language. For this language, the paper presents the process of generating code for the user interface elements. This includes model transformation procedures to generate window initiation code and event handlers associated with these windows. The process is illustrated with an example based on an actual system developed using the presented approach.
Źródło:
e-Informatica Software Engineering Journal; 2014, 8, 1; 39-52
1897-7979
Pojawia się w:
e-Informatica Software Engineering Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selective agglomeration of magnetite in entlandite-serpentine system and implication for their separation
Autorzy:
Lu, J.
Yuan, Z.
Liu, J.
Li, L.
Wang, N.
Meng, Q.
Powiązania:
https://bibliotekanauki.pl/articles/110411.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
serpentine
pentlandite
magnetite
selective magnetic agglomeration
magnetic separation
Opis:
In nickel sulfide processing, magnesium silicates (serpentines) can easily form slime coatings or hetero-aggregation on pentlandite surfaces, and hence decrease the pentlandite flotation rate and recovery. In this work, magnetic separation of pentlandite from serpentine using selective magnetic coating through adding magnetite fines as magnetic seeds was investigated. Interactions of magnetite-pentlandite and magnetite-serpentine were calculated by the DLVO (Derjaguin-Landau-Verwey-Overbeek) theory. The results show that the interaction of magnetite-pentlandite was obviously stronger than that of magnetite-serpentine with an external weak magnetic field (4776 A/m-1). Therefore, fine magnetite fractions selectively adhered to the pentlandite surfaces and enhanced its magnetism, resulting in being separated from serpentine by magnetic separation, which was further verified by magnetic coating-magnetic separation and SEM observations.
Źródło:
Physicochemical Problems of Mineral Processing; 2017, 53, 2; 943-955
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of the biomechanical behaviour of articular cartilage in hindfoot joints
Autorzy:
Venturanto, C.
Pavan, P. G.
Forestiero, A.
Carniel, E. L.
Natali, A. N.
Powiązania:
https://bibliotekanauki.pl/articles/307388.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ankle joint
articular cartilage
constitutive model
numerical analysis
staw skokowy
chrząstka stawowa
analiza numeryczna
Opis:
Numerical models represent a powerful tool for investigating the biomechanical behavior of articular cartilages, in particular in the case of complex conformation of anatomical site. In the literature, there are complex non-linear-multiphase models for investigating the mechanical response of articular cartilages, but seldom implemented for the analysis of high organized structure such as the foot. In the present work, the biomechanical behavior of foot cartilage is investigated by means of a fiber-reinforced hyperelastic constitutive model. The constitutive parameters are obtained through the comparison between in vitro experimental indentation tests on cartilage and numerical analysis data interpreting the specific experimental conditions. A finite element model of the hindfoot region is developed. Particular attention is paid to model cartilage in order to respect its morphometric configuration, including also the synovial capsule. The reliability of the procedure adopted is evaluated by comparing the numerical response of tibio-talar joint model with in vivo experimental tests mimicking the foot response in stance configuration.
Źródło:
Acta of Bioengineering and Biomechanics; 2014, 16, 2; 57-65
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simultaneous extraction of vanadium and chromium from vanadium slag using low-pressure liquid phase oxidation method
Autorzy:
Xia, J.-P.
Zheng, S.-L.
Wang, S.-N.
Liu, B.
Zou, X.
Powiązania:
https://bibliotekanauki.pl/articles/110818.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
vanadium slag
low pressure leaching
liquid phase oxidation
kinetics
Opis:
A low-pressure liquid oxidation method was proposed and proven to be effective to extract vanadium and chromium simultaneously from the vanadium slag in concentrated NaOH aqueous solutions. The effect of temperature, NaOH mass concentration, liquid-to-solid mass ratio, stirring speed and pressure on the extraction of vanadium and chromium in NaOH aqueous solutions were systematically investigated. Under the optimal reaction conditions (temperature of 473 K, liquid-to-solid mass ratio of 6:1, stirring speed of 700 rpm, NaOH mass concentration of 50%, pressure of 1 MPa and reaction time of 180 min), the vanadium and chromium recovery reached 95% and 90%, respectively. It was found that the reaction temperature and NaOH concentration were important factors for the extraction of vanadium and chromium. The kinetics of the decomposition of vanadium slag in concentrated NaOH aqueous under low pressure was analyzed using the shrinking core model, and the results indicated that the extraction of vanadium and chromium were both governed by the internal diffusion step, with apparent activation energies calculated to be 26.22 and 32.79 kJ/mol, respectively.
Źródło:
Physicochemical Problems of Mineral Processing; 2018, 54, 2; 609-619
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Error reduction of the Doppler lidar signal using a re-normalization method
Autorzy:
Park, N G
Baik, S H
Park, S K
Kim, D L
Kim, D. H.
Powiązania:
https://bibliotekanauki.pl/articles/173914.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
injection-seeded laser
Doppler lidar
frequency locking
wind lidar
Doppler velocity measurement
Opis:
In this paper, we present a re-normalization method for a Doppler signal of a Doppler lidar system. For the Doppler lidar system, we used an injection-seeded pulsed Nd:YAG laser as a transmitter and an iodine cell as a Doppler frequency discriminator. A frequency locking system that uses the absorption feature of iodine gas is too sensitive to the external or internal noises (iodine cell temperature instability, laser frequency fluctuation, environmental noises, etc.) to maintain its locking point ideally, and this frequency locking error makes the Doppler lidar system acquire the noises as the Doppler frequency shifts. To reduce the Doppler signal error induced by a frequency locking error, we used a re-normalization method by an addition of a laser beam path separated from a transmitter to the Doppler frequency discriminator for re-normalization. In this method, fluctuations of the Doppler signal were reduced using the reference signal. The reduced amount of standard deviation between the Doppler signal and the re-normalization signal was 4.838×10–3 and the Doppler signals showed a 53.3% fluctuation reduction of the averaged error value by this method.
Źródło:
Optica Applicata; 2014, 44, 1; 103-111
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adsorption of arsenic on granular ferric hydroxide (GEH®). Impact of initial concentration of arsenic(V) on kinetics and equilibrium state
Autorzy:
Saldaña-Robles, A.
Márquez-Herrera, A.
Ruiz-Aguilar, G. M. L.
Flores-Ortega, A.
Saldaña-Robles, N.
Powiązania:
https://bibliotekanauki.pl/articles/207941.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
adsorption
groundwater
kinetics
adsorpcja
wody podziemne
kinetyka
Opis:
The present study discusses the adsorption kinetics of arsenic(V) on granular ferric hydroxide (GEH) and the GEH adsorption capacity for arsenic(V) at equilibrium. The impact of temperature on GEH adsorption capacity was studied, as well as the effects of the initial concentration of arsenic(V) and GEH concentration on the adsorption rates of arsenic(V). The Freundlich isotherm describes the arsenic(V) adsorption behavior reasonably well (r2 > 0.965). The adsorption kinetics was studied by fitting the experimental data to both first-order and second-order models. The maximum adsorption capacity of arsenic(V) on GEH was 2.701 mg·g–1, which is higher than the adsorption capacities of other adsorbents reported. The kinetics of arsenic(V) adsorption was well defined by the second-order model, with the correlation coefficients in the range of 0.960–0.987. This study shows that due to its properties, GEH is a good candidate for removal of arsenic(V) from groundwater.
Źródło:
Environment Protection Engineering; 2018, 44, 3; 51-62
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies