Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Huang, G." wg kryterium: Autor


Wyświetlanie 1-6 z 6
Tytuł:
Effect of gas holdup on the efficiency of cyclonic-static microbubble flotation column for oily wastewater treatment
Autorzy:
Ning, K.
Huang, G.
Xu, H.
Wu, L.
Li, X.
Wang, Y.
Powiązania:
https://bibliotekanauki.pl/articles/208139.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
bubble columns
efficiency
flotation
wastewater treatment
oil water separation
kolumna flotacyjna
efektywność
flotacja
oczyszczanie ścieków
separacja wody
Opis:
A cyclonic-static microbubble flotation column of a novel construction was used in oil-water separation fields and has high efficiency for oil-water separation. The gas holdup is a key parameter for the evaluation of the performance of a flotation column. The gas holdup, closely related to the bubble size, bubble velocity and superficial gas velocity, is one of the most important parameters characterizing the hydrodynamics of a bubble column. The effect of gas holdup in a cyclonic-static microbubble flotation column was investigated. In addition, several operating parameters such as the circulating pressure, superficial gas velocity, and frother consumption were also investigated. The gas holdup was positively correlated to the superficial gas velocity. The gas holdup of clean water and oil wastewater increased along with the increase of the frother consumption. The separation mechanism of cyclonic-static microbubble flotation column was analyzed.
Źródło:
Environment Protection Engineering; 2018, 44, 2; 5-17
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kinetic research of quinoline, pyridine and phenol adsorption on modified coking coal
Autorzy:
Sun, X.
Xu, H.
Wang, J.
Ning, K.
Huang, G.
Yu, Y.
Ma, L.
Powiązania:
https://bibliotekanauki.pl/articles/110365.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
adsorption kinetics
modification
coking coal
coking wastewater
Opis:
Adsorption is widely used in wastewater treatment. In this work, the removal of quinoline, pyridine and phenol from coking wastewater by using modified coking coal, which was treated by four different modification methods i.e. acidification sodium hydroxide (5 mol/dm3), hydrochloric acid (5 mol/dm3) and acetic acid (5 mol/dm3) and low-temperature (105 oC) oxidation, was investigated. The modified coal was characterized by the surface area analysis, SEM, total acidity and basicity and FT-IR. The results showed that the surface area from high to low follows the order: modification with acetic acid, modification with hydrochloric acid, raw coal, modification with sodium hydroxide and modification with low-temperature. Experimental data were fitted to pseudo-first-order, pseudo-second-order and intra-particle diffusion. The adsorption of all followed pseudo-second-order kinetics. The result showed that the removal efficiency of coal modified by hydrochloric acid and acetic acid are higher than raw coal, while modified by sodium hydroxide and low-temperature are lower than raw coal., The coal modified by hydroxide acid had the best adsorption capacity.
Źródło:
Physicochemical Problems of Mineral Processing; 2018, 54, 3; 965-974
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The optimization of the dielectric layer photonic crystal filter by the quadratic response surface methodology
Autorzy:
Yang, H.
Meng, S
Wang, G.
Huang, C.
Powiązania:
https://bibliotekanauki.pl/articles/174592.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
optimization
photonic crystal filter
response surface methodology
Opis:
Dielectric layer photonic crystal filter structures in waveguide are optimized by the quadratic response surface methodology. The optimization model of the filter is established on the basis of the analysis which is conducted with the aid of the response surface methodology. The model is solved using sequential quadratic programming and the optimal parameters are obtained. Examples demonstrate it is effective.
Źródło:
Optica Applicata; 2015, 45, 3; 369-379
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the influence of the transducer and its coupling layer on round window stimulation
Autorzy:
Liu, H.
Xu, D.
Yang, J.
Yang, S.
Cheng, G.
Huang, X.
Powiązania:
https://bibliotekanauki.pl/articles/306655.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
słuch
stymulacja
przetwornik
RW
FEM
implantable middle ear hearing device
round window stimulation
transducer
coupling layer
finite element analysis
Opis:
Purpose: In this work, a finite element study is proposed to evaluate the effects of the transducer and its coupling layer on the performance of round window (RW) stimulation. Methods: Based on a set of micro-computer tomography images of a healthy adult’s right ear and reverse engineering technique, a coupled finite-element model of the human ear and the transducer was constructed and verified. Then, the effect of the cross-section of the transducer, the elastic modulus of the coupling layer, the mass of the transducer, and the preload of the transducer were studied. Results: The increase of the transducer’s cross-section area deteriorates the RW stimulation, especially at the lower frequencies. This adverse effect of the cross-section area’s increase of the transducer can be reduced by adding a coupling layer between the transducer and the RW. However, the coupling layer’s improvement on the RW stimulation is reduced with the increase of its elastic modulus. Moreover, the mass loading of the transducer decreases the RW stimulation’s performance mainly at higher frequencies and applying a static preload on the transducer enhances its hearing compensating performance at higher frequencies. Conclusions: The influence of the transducer’s mass, the mass of the transducer, the applied static preload and the properties of the coupling layer must be taken into account in the design of the RW stimulation type implantable middle ear hearing device.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 2; 103-111
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adsorption behavior of Zn(II) onto natural minerals in wastewater. A comparative study of bentonite and kaolinite
Autorzy:
Chai, W.
Huang, Y.
Su, S.
Han, G.
Liu, J.
Cao, Y.
Powiązania:
https://bibliotekanauki.pl/articles/109926.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
adsorption
Zn(II)
wastewater
clay minerals
structural properties
Opis:
In order to remove the harmful metal ions in lead-zinc mineral processing wastewater, two natural clay minerals (bentonite and kaolin) were used as adsorbents and Zn(II) ions were the emphasis in this work. The adsorption behaviors including kinetics and isotherms were investigated by batch experiments. In addition, the adsorption mechanisms were studied by means of zeta potential testing, optical microscope and XRD analysis. The results show that the adsorption process can be best described as the pseudo-second order kinetic model. The adsorption equilibrium data of bentonite and kaolinite can be respectively fitted best by Langmuir and Freundlich models. Thermodynamic studies display that the adsorption of Zn(II) onto clays is non-spontaneous and endothermic. The maximum capacity of Zn(II) adsorbed on bentonite and kaolinite respectively reaches to 79.2 mg·g-1 and 6.35 mg·g-1 at 25 °C. The structural differences of bentonite and kaolinite result in the differences in adsorption behavior and mechanism. The interaction mechanisms of Zn(II) with bentonite and kaolinite involve electrostatic attraction, cation exchange, surface complex and precipitation. Bentonite as adsorbent has the potential to remove Zn2+ better than kaolinite.
Źródło:
Physicochemical Problems of Mineral Processing; 2017, 53, 1; 264-278
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Room-temperature sensing performance of hydrogen using palladium-based film by optical setup
Autorzy:
Yao, Yiyun
Corso, Alain J.
Bazzan, Marco
Tessarolo, Enrico
Wang, Zhanshan
Huang, Qiushi
Qi, Runze
Martucci, A.
Pelizzo, Maria G.
Powiązania:
https://bibliotekanauki.pl/articles/1835811.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
hydrogen detection
palladium-based film
palladium–platinum alloy film
optical sensor
Opis:
H2 sensing performance of novel Pd–Pt alloy films has been compared with those obtained by using Pd films and H2-reducted PdO films. Two different detecting systems were used to measure the hydrogenation and de-hydrogenation phases with a H2 concentration of both 5% v/v nitrogen and 1% v/v nitrogen at room temperature. The sensitivity loss observed for the Pd–Pt alloy and H2-reducted PdO samples with respect to pure Pd samples can be explained in terms of the reduction in the lattice constant and interstitial volume due to the Pt addition, which determine a decrement of hydrogen atoms penetrating in the films. On the other hand, results show an improvement in time-response for Pd–Pt alloy and H2-reducted PdO films with respect to pure Pd ones, presumably due to the increase of its permeability to H2. Moreover, the sensing measurements repeated after 60 days show that the Pd–Pt alloy films, unlike the Pd-based ones, fully preserve their performances, demonstrating the advantage of the Pt inclusion for stability purposes when the samples are stored upon humidity.
Źródło:
Optica Applicata; 2020, 50, 4; 649-661
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies